(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
| Days to Ship |
|
|---|

MELSEC-F Input Expansion Board / Output Expansion Board
MITSUBISHI
Input expansion board for MELSEC-F Series.
[Features]
· Can expand input by 4 points and output by 2 points.
· Expansion board that can be built into an FX3S and FX3G sequencer.
· The power is supplied from the base unit.
| Standard Price: | MYR 246.67- |
|---|---|
| Special Price | |
| Days to Ship: | 65 Day(s) |

MITSUBISHI
- CT input module, MELSEC-Q series from MITSUBISHI.
- The direct connection of the CT (Current Transformer) sensor and the programmable controller has eliminated the need to connect a separate signal converter.
- Direct CT (Current Transformer) sensor connection reduces wiring and saves space. Directly connect to the CT sensor without an external signal converter. The AC current for up to eight channels can be measured with one unit, by that reducing the wiring steps and costs.
- The device can be serviced, and troubleshooting is performed by detecting the peak current.
| Standard Price: | MYR 4,995.00 |
|---|---|
| Special Price | |
| Days to Ship: | 97 Day(s) |

NX Series Digital Output Unit NX-OD Transistor Output Unit
OMRON
Digital output unit that is available in many variations, from high-speed types that enable high-speed synchronization control to general-purpose types
■ Features
· Can be mounted on an EtherCAT coupler to enable high-speed I/O refreshing
· Enables I/O refreshing synchronized with the controller control period (synchronous refresh)
· Using this unit in combination with an NX Series CPU Unit or EtherCAT Coupler Unit, an NX unit that uses a time stamping input method,
and an NX unit that uses a time-specific output method enables highly precise I/O control that does not depend on the
controller's control period
· The use of a removable terminal block improves system maintainability
· The Push-In Plus terminal block (screwless clamp terminal block) and connector type (MIL connector / Fujitsu connector)
greatly reduce the time required for wiring work
· A unit width of only 12 mm realizes space saving (connector type 30 mm)
· 2-, 4-, 8-, 16- and 32-output-contact types are available, enabling the I/O configuration that best suits your equipment
· Connect to the CJ Series using the EtherNet/IP coupler
| Standard Price: | MYR 521.62- |
|---|---|
| Days to Ship: | 5 Day(s) or more |

NX Series Digital Input/Output Combined Unit NX-MD DC Input / Transistor Output Unit
OMRON
Digital input unit that is available in many variations, from high-speed types that enable high-speed synchronization control to general-purpose types
■ Features
· Can be mounted on an EtherCAT coupler to enable high-speed I/O refreshing
· Enables I/O refreshing synchronized with the controller control period (synchronous refresh)
· Using this unit in combination with an NX Series CPU Unit or EtherCAT Coupler Unit, an NX unit that uses a time-stamping input method,
and an NX unit that uses a time-specific output method enables highly precise I/O control that does not depend on the
controller's control period
· The use of a removable terminal block improves system maintainability
· The Push-In Plus terminal block (screwless clamp terminal block) and connector type (MIL connector / Fujitsu connector)
greatly reduce the time required for wiring work
· A unit width of only 12 mm realizes space saving (connector type 30 mm)
· Connect to the CJ Series using the EtherNet/IP coupler
| Standard Price: | MYR 1,553.82 |
|---|---|
| Days to Ship: | 5 Day(s) or more |

NX Series Digital Input Unit NX-ID DC Input Unit
OMRON
Digital input unit that is available in many variations, from high-speed types that enable high-speed synchronization control to general-purpose types
■ Features
· Can be mounted on an EtherCAT coupler to enable high-speed I/O refreshing
· Enables I/O refreshing synchronized with the controller control period (synchronous refresh)
· Using this unit in combination with an NX Series CPU Unit or EtherCAT Coupler Unit, an NX unit that uses a time-stamping input method,
and an NX unit that uses a time-specific output method enables highly precise I/O control that does not depend on the
controller's control period
· The use of a removable terminal block improves system maintainability
· The Push-In Plus terminal block (screwless clamp terminal block) and connector type (MIL connector / Fujitsu connector)
greatly reduce the time required for wiring work
· A unit width of only 12 mm realizes space saving (connector type 30 mm)
· 4-, 8-, 16- and 32-input-contact types are available, enabling the I/O configuration that best suits your equipment
· Connect to the CJ Series using the EtherNet/IP coupler
| Standard Price: | MYR 521.45- |
|---|---|
| Days to Ship: | 5 Day(s) or more |

NX Series Position Interface Pulse Output Unit NX-PG0□□□
OMRON
Positioning control with pulse outputs to command stepper motor drives and other pulse input motor drives
■ Features
· The MC Function Module of the NJ/NX/NY5 Controller allows you to
connect with as many axes as the NJ/NX/NY5 Controller can control
· High-speed remote I/O control with communications cycle as fast as 125 μs*1
· Multiple stepping motors and servo motors can be operated in synchronization by
using synchronous I/O refreshing or task period prioritized refreshing*2
· Latching (2 external latch inputs)
· Open collector pulse outputs up to 500 kHz
or line driver pulse outputs up to 4 MHz
· Line driver output models with 2 or 4 channels
*1 When using the NX-EC01□□ together with the NX701-□□□□ and NX-ECC203.
* *2 Task period prioritized refreshing is available when the NX-ECC203 is used together.
| Standard Price: | MYR 2,635.44- |
|---|---|
| Days to Ship: | 5 Day(s) or more |

I/O Unit For MELSEC iQ-FX5 Series
MITSUBISHI
- I/O Unit for MELSEC iQ-FX5 Series, Analog control type from MITSUBISHI.
- Using analog input and output devices, operations such as input and output of analog quantities (voltage, current, etc.), temperature input and adjustment, etc. can be performed.
- Use the ample lineup of extension modules for analog control that matches your applications.
- 3 types available, Analog input (FX5-4AD), Analog Output (FX5-4DA) and Temperature control (FX5-4LC, FX5-8AD)
- I/O channel can be selected up to 8 channels.
| Standard Price: | MYR 2,150.00- |
|---|---|
| Special Price | |
| Days to Ship: | 4 Day(s) or more |

MELSEC iQ-F Input/Output Expansion Block (Input/Output Unit) FX5
MITSUBISHI
Input/output expansion block that receives power from the basic / power supply unit of the MELSEC iQ-F series.
[Features]
・ It can be connected to the back of a basic unit or expansion unit
[Applications]
・ Convenient for expanding input/output, receiving power supply from a basic unit or expansion unit
・ It can be used for FX5UJ, FX5U, FX5UC, etc.
| Standard Price: | MYR 1,043.33- |
|---|---|
| Special Price | |
| Days to Ship: | 97 Day(s) |

CC-Link IE Field Network, Block Type Remote Unit NZ2GN Series
MITSUBISHI
The block type remote unit is a slave station of the CC-Link IE TSN network.
[Features]
・Input/output devices can be more easily distributed according to the equipment
・The input/output unit can be connected to various devices that handle ON/OFF signals, such as switches, sensors, and actuators that are the basis of control systems
・The analog unit can be connected to devices that handle analog values such as voltage and current
・In addition, safe communication can be realized by combining a block type remote unit with a safety function with a safety CPU
・Parameters can be easily set with just a switch
・It can detect the power supply voltage drop of the unit
・Wiring labor-hours can be reduced by the spring clamp terminal block
・The input unit complies with IEC61131-2 (digital input standard operating range) Type3, and various sensors can be connected
・It can also operate as a slave station of CC-Link IE field network
・Safety control is also possible with a block type remote unit with a safety function
・Since the input/output timing can be adjusted to the synchronization cycle between units, highly accurate control of the system is possible
| Standard Price: | MYR 1,706.66- |
|---|---|
| Special Price | |
| Days to Ship: | 97 Day(s) |

Expansion unit for CC-Link IE Field Network block-type remote unit
MITSUBISHI
[CC-Link IE Field Network, Block Type Remote Unit]
・ CC-Link IE field network remote device station. Input/output devices can be more easily distributed according to the equipment
・ You can easily add the number of input/output points by connecting expansion units
・ It supports CC-Link IE field network synchronous communication function. Since the operation can be performed according to the synchronization cycle of the master station that supports the synchronous communication function, the operation timings of multiple slave stations can be aligned
・ Units that support the fast link-up function can quickly return to the line when the CC-Link IE field network is disconnected and then reconnected
・ Units that support the automatic I/O parameter setting function can operate the input/output unit without setting parameters, so the startup time can be shortened
| Standard Price: | MYR 1,281.67- |
|---|---|
| Special Price | |
| Days to Ship: | 97 Day(s) |

CC-Link IE Field Network block-type remote unit NZ2GF Series
MITSUBISHI
[CC-Link IE Field Network, Block Type Remote Unit]
・ CC-Link IE field network remote device station. Input/output devices can be more easily distributed according to the equipment
・ You can easily add the number of input/output points by connecting expansion units
・ It supports CC-Link IE field network synchronous communication function. Since the operation can be performed according to the synchronization cycle of the master station that supports the synchronous communication function, the operation timings of multiple slave stations can be aligned
・ Units that support the fast link-up function can quickly return to the line when the CC-Link IE field network is disconnected and then reconnected
・ Units that support the automatic I/O parameter setting function can operate the input/output unit without setting parameters, so the startup time can be shortened
| Special Price | |
| Days to Ship: | 4 Day(s) or more |
| Standard Price: | MYR 859.80- |
|---|---|
| Days to Ship: | Quote |

MELSEC-Q Series DC Digital Input Unit With Conformal Coating
MITSUBISHI
- MELSEC-Q Series DC Digital Input Unit with Conformal Coating from MITSUBISHI.
- DC digital input unit with conformal coating - FCN - Mitsubishi Electric (MELSEC-Q Series (QnU)) - 64I/O [64DI (64 x digital inputs (24Vdc; high-speed; Sink))] - equivalent to QX42S1C.
- The Q Series I/O and intelligent function module lineup is extensive and capable of meeting the needs of a wide range of applications.
- Attain the ideal solution for the application, whether it be high speed positioning or high accuracy temperature control.
| Standard Price: | MYR 2,085.00 |
|---|---|
| Special Price | |
| Days to Ship: | 97 Day(s) |

Spring Clamp Terminal Block Model Q6TE-18SN
MITSUBISHI
The Q6TE-18SN shall be used attached to a Q-Series terminal block-type I/O module or an intelligent function module.
Since the Q6TE-18SN uses a spring clamp, it does not require screw-tightening, which greatly reduces the number of wiring procedures.
| Standard Price: | MYR 118.33 |
|---|---|
| Special Price | |
| Days to Ship: | 79 Day(s) |
| Standard Price: | MYR 2,892.75 |
|---|---|
| Days to Ship: | Quote |
| Standard Price: | MYR 485.00- |
|---|---|
| Special Price | |
| Days to Ship: | 97 Day(s) |
| Standard Price: | MYR 1,323.33 |
|---|---|
| Special Price | |
| Days to Ship: | 97 Day(s) |
| Brand |
|---|
| Product Series |
| Days to Ship |
| Number Of Inputs |
| Input Format |
| Rated Input Voltage(V) |
| Input answer time |
| Number of Outputs |
| Output Format |
| Rated load voltage(V) |
| Protection function |
| Connection Terminal |
| Representative Standard |
|
|
|
|
|
|
|
|
|
|
| |||||||
| Brand | MITSUBISHI | MITSUBISHI | OMRON | OMRON | OMRON | OMRON | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | FESTO | MITSUBISHI | MITSUBISHI | FESTO | MITSUBISHI | MITSUBISHI |
| Product Series | NX Series Digital Input/Output Combined Unit NX-MD DC Input / Transistor Output Unit | MELSEC iQ-F Input/Output Expansion Block (Input/Output Unit) FX5 | CC-Link IE Field Network, Block Type Remote Unit NZ2GN Series | Expansion unit for CC-Link IE Field Network block-type remote unit | CC-Link IE Field Network block-type remote unit NZ2GF Series | MELSEC-Q Series DC Digital Input Unit With Conformal Coating | |||||||||||
| Days to Ship | 65 Day(s) | 97 Day(s) | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 5 Day(s) or more | 4 Day(s) or more | 97 Day(s) | 97 Day(s) | 97 Day(s) | 4 Day(s) or more | Quote | 97 Day(s) | 79 Day(s) | Quote | 97 Day(s) | 97 Day(s) |
| Number Of Inputs | 4 ~ NA | - | - | 16 | 4 ~ 32 | - | 4 ~ 8 | 4 ~ 8 | 8 ~ 32 | 16 | 16 ~ 32 | 4 ~ 16 | - | - | 16 | - | - |
| Input Format | - | - | - | DC input | - | - | - | DC input | DC input | DC input | DC input / AC input | - | - | - | - | - | - |
| Rated Input Voltage(V) | DC24V ~ Not available | - | - | 24 | 12 to 24 DC ~ 24 DC | - | DC-10~+10 ~ DC24 | DC13 to 30 ~ DC24 | 24 | 24 | 24 ~ 100~120 | 18-30 DC ~ 24 DC | DC 24 | - | 18-30 DC | - | - |
| Input answer time | - | - | - | - | - | - | - | - | Less than 50 to 100 mS | - | Less than 50 to 100 mS | - | - | - | - | - | - |
| Number of Outputs | 2 ~ NA | - | 2 ~ 32 | 16 | - | - | 4 ~ 8 | 4 ~ 8 | 8 ~ 32 | 16 | 16 ~ 32 | - | - | - | - | - | - |
| Output Format | Other | - | Other | Other | - | Other | Transistor / sync output | Transistor / source output / Transistor / sync output | Transistor / source output / Transistor / sync output | Transistor / source output / Transistor / sync output | Relay contact output / Triac output / Transistor / source output / Transistor / sync output | - | - | - | - | - | - |
| Rated load voltage(V) | - | - | - | - | - | - | DC-10~+10 ~ DC24 | - | DC12/24 ~ DC24 | 12$24 | 12/24 ~ AC100~240 | - | - | - | - | - | - |
| Protection function | - | - | - | - | - | - | - | - | None / Output protection function | None | None | - | - | - | - | - | - |
| Connection Terminal | - | - | Terminal Block / Connector | Connector | - | - | Connector / Terminal block/connector | Terminal Block | Terminal Block / Connector | Terminal Block | Terminal Block / Connector | - | - | - | - | - | - |
| Representative Standard | CE | CE / UL / CUL | CE / UL / CUL / CSA | CE / UL / CUL / CSA | CE / UL / CUL / CSA | CE / UL / CUL / CSA | CE / UL / CUL | CE / UL / CUL | CE / UL / CUL | - | CE / UL / CUL | - | - | - | - | - | - |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy