(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
[Features]· Universal AC input / Full range.· Withstand 300 V AC surge input for 5 seconds.· Built-in active PFC function.· Protections: Short circuit / Overload / Overvoltage / Over temp. (optional for HRP-75 / HRP-100)· Built-in constant current limiting circuit.· Built-in remote sense function (HRP□-150 / 200)· No load power consumption <0.5 W (except for HRP-150/200)· Built-in remote ON/OFF control (except for HRP-150/200)· Built-in 5 V / 0.3 A standby output (HRPG-150/200)· Cooling by free air convection.· 1U low profile.· LED indicator for power on.· 100% full load burn-in test.
Part Number
Configured Part Number is shown.
| Part Number |
|---|
| HRP-100-12 |
| HRP-100-24 |
| HRP-150-24 |
| HRP-200-24 |
| HRP-300-24 |
| HRP-600-24 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Capacity (W) | Output voltage (Single only) | Rated output current (single only) (A) | Included Function | Dimension height (mm) | Dimension width (mm) | Dimension depth (mm) | Rated output current 1 for DC 24 V (A) | Rated output current 2 for DC 12 V (A) | AC Input current (Maximum) | DC adjustment range | Effi. | Withstand Voltage | Operating temperature |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 252.85 | 1 Piece(s) | 4 Day(s) or more | 100 ~ 102 | DC12V | 8.5 | - | 97 ~ 159 | 38 ~ 97 | 38 ~ 169 | - | 8.5 | Cold start, 65A at 230VAC | -5%~+10% rated output voltage | 87.5% | I/P-O/P: 3kVAC, I/P-FG: 1.5kVAC, O/P-FG: 0.5kVAC, 1 minute | -40~+60°C | ||
MYR 252.85 | 1 Piece(s) | 4 Day(s) or more | 100 ~ 108 | DC24V | 4.5 | - | 97 ~ 159 | 38 ~ 97 | 38 ~ 169 | 4.5 | - | Cold start, 65A at 230VAC | -5%~+10% rated output voltage | 88.5% | I/P-O/P: 3kVAC, I/P-FG: 1.5kVAC, O/P-FG: 0.5kVAC, 1 minute | -40~+60°C | ||
MYR 309.04 | 1 Piece(s) | 2 Day(s) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
MYR 365.23 | 1 Piece(s) | 4 Day(s) or more | 200 ~ 201.6 | DC24V | 8.4 | - | 98 ~ 199 | 38 ~ 98 | 38 ~ 212 | 8.4 | - | Cold start; 70A at 230VAC | ±15% rated output voltage | 88.0% | I/P-O/P: 3kVAC, I/P-FG: 1.5kVAC, O/P-FG: 0.5kVAC, 1 minute | -40~+70°C | ||
MYR 449.52 | 1 Piece(s) | 4 Day(s) or more | 300 ~ 336 | DC24V | 14 | Fan for cooling | 105 ~ 199 | 41 ~ 105 | 41 ~ 216 | 14 | - | Cold start, 70A at 230VAC | ±15% rated output voltage | 87.0% | I/P - O/P: 3kVAC, I/P - FG: 1.5kVAC, O/P - FG: 0.5kVAC, 1 minute | -40~+70°C (refer to output derating curve) | ||
MYR 820.37 | 1 Piece(s) | 4 Day(s) or more | 600 ~ 648 | DC24V | 27 | Fan for cooling | 105 ~ 218 | 63.5 ~ 105 | 63.5 ~ 248 | 27 | - | Cold start, 70A at 230VAC | ±15% rated output voltage | 88.0% | I/P - O/P: 3kVAC, I/P - FG: 1.5kVAC, O/P - FG: 0.5kVAC, 1 minute | -40~+70°C (refer to output derating curve) |
Loading...
| Shape | With Cover | Single/multi | Single | Input Voltage | AC/DC |
|---|---|---|---|---|---|
| Input/output terminal shape | Screw | Representative Standard | CE / UL / CUL / TUV | AC Input Voltage Range | 85~264VAC; 120~370VDC |
| Overload protection | 105%~135% Constant current limiting, auto-recovery | Over voltage protection | 115%~145% | Safety Standard | UL60950-1, TUV EN60950-1 approved |
| EMC standards | EN55022 class B, EN61000-4-2,3,4,5,6,8,11, EN61000-3-2,3, EN61000-6-2 heavy industry level |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy