[Features]
· Immediate checks can be made on-site whenever necessary.
· Simple power logger enables intelligent checks of various circuits from device power to switchboard power.
· Remote monitoring and setting from a PC, PLC, etc. is possible with the built-in LAN port.
· AC adapter for logging over a long period.
· SD card slot for easy data collection.
· Alarm output alerts of errors. Measurement range 0.03 to 400A (CT5 type).
Japanese Only
Part Number
Configured Part Number is shown.
ZN-CTX21

Simplified Power Logger appearance

Simplified Power Logger external dimension diagram 1; unit: mm

Simplified Power Logger external dimension diagram 2; unit: mm

Simplified Power Logger external dimension diagram 3; unit: mm

Simplified Power Logger screw hook‑holes cutting dimension diagram; unit: mm

Simplified Power Logger mounting holes dimension diagram; unit: mm
| Item | Format | |
|---|---|---|
| Model ZN-CTX21 | Model ZN-CTX21-A | |
| Phase-Wire Type | For standard-type CTs: single-phase 2-wire / 3-phase 3-wire (treated as balanced 3-phase) For split-type CTs: single-phase 2-wire / single-phase 3-wire / 3-phase 3-wire / 3-phase 4-wire | |
| Display | 7-segment LCD with 5 digits on 2 rows, and supplemental information indicators | |
| Recording Interval | 1 s, 2 s, 5 s, 10 s, 20 s, 30 s and 1 min *1 | |
| Conversion Function | Instantaneous power and cumulative power consumption *2 | |
| Measurement Operation Modes | Normal mode, sleep mode *3 and high-speed logging mode *4 | |
| Recording Mode | Continue *5, ring *6 | |
| External Output | Alarm output (photocoupler output) *7 | |
| Storage Device (Internal) | Internal memory: Approx. 6,500 data items (1 data item: 70 bytes or less (when number of channels is 1)) | |
| Storage Device (External) | SD card (to save measured values and to save/read-out set values) / Recommended SD card: HMC-SD291 model (manufactured by OMRON Corporation) *8 | |
| Power Supply | DC Input: 24 V DC ±10%; AC Adapter: 100 to 240 V AC / 50 to 60 Hz Battery: 2 AAA batteries *9 | |
| Current Consumption | 80 mA or lower (using an AC adapter) | |
| Battery Life *10 | Approx. 1 week *11 | |
| Operating Temperature Range | Battery powered: -10 to +60°C (no condensation or freezing) Using an AC adapter: 0 to +40°C (no condensation or freezing) | |
| Operating Humidity Range | 20 to 85% RH (no condensation or freezing) | |
| Storage Temperature And Humidity Range | -15°C to +60°C, 20 to 85% RH (no condensation or freezing) | |
| Insulation Resistance | 20 MΩ (at 500 V DC Mega) | |
| Dielectric Withstand Voltage | 1,000 V AC, 50/60 Hz for 1 min: between case and input/output terminal | |
| Vibration (Resistance) | With mounting screws: 10 to 150 Hz, with double amplitude of 0.7 mm, acceleration of 50 m/s2 for 80 min each in X, Y and Z directions With mounting magnets: 10 to 55 Hz, with double amplitude of 0.3 mm, acceleration of 20 m/s2 for 50 min each in X, Y and Z directions | |
| Shock (Resistance) | 150 m/s2 3 times each in 6 directions (up/down, left/right and forward/backward) *12 | |
| Material | ABS | |
| Degree Of Protection | IP30 | |
| Mounting Method | Magnet/screw/screw-hook mounting | |
| Mass (packaged) | Approx. 500 g | |
| Accessory 1 | Instruction manual, start-up guide, mounting magnets *13 and alarm output connector *14 | |
| Accessory 2 | AC adapter *15 | DC cable (straight type), ferrite core |
Warning
For safety purposes, this product cannot be used in applications for direct or indirect human-body detection.
Do not use this product as a detection device for human safety.
| Part Number |
|---|
| ZN-CTX21 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship |
|---|---|---|---|---|
MYR 1,646.32 | 1 Piece(s) | 21 Day(s) or more |
Loading...
| Type | Simple Power Logger | Usage Form | Handy | External interface | Ethernet |
|---|---|---|---|---|---|
| External storage | Applicable | Battery drive time(h) | 168 | Display | Liquid Crystal 7 Segment 5 Digits 2 Levels |
| Measurement Application Circuit (Power Logger) | Single-phase Two-wire/Single-phase three-wire/Three-phase Three-wire/Three-phase Four-wire | Function | Current Value/Instantaneous Power/Integral Power Energy | Material | ABS |
| Protective Structure | IP30 | Note | AC adapter included |
Please check the type/dimensions/specifications of the part ZN-CTX21 in the Simple Power Logger ZN-CTX/CTS/CTM series.

OMRON
Standard Price : MYR 252.38-
Days to Ship : 2 Day(s) or more


OMRON
Standard Price : MYR 1,321.37
Days to Ship : 7 Day(s) or more

OMRON
Standard Price : MYR 155.55
Days to Ship : 5 Day(s) or more


How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy