(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

Molded Case Circuit Breakers (MCCB) NF-CV/SV (NF63-CV 3P 20A)

Molded Case Circuit Breakers (MCCB) NF-CV/SV NF63-CV 3P 20A

· Molded Case Circuit Breakers (MCCB) NF-CV/SV series from MITSUBISHI.
· Rated Current Range: 3.4A to 63A (varies by model)
· Number of Poles: 2, 3, or 4 (model-dependent)
· Rated Insulation Voltage: 500V or 600V (model-dependent)
· Rated Short-Circuit Breaking Capacity: AC voltages: 230V to 690V, DC voltage: 250V (for some models)
· Short-Circuit Breaking Capacity Range: 2.5/2.5 kA to 75/75 kA (varies by voltage and model)
· Standard Attached Parts: Terminal screw: M5×14, Mounting screw: M4×0.7×55 and Insulation barrier

PDF

Part Number

Configured Part Number is shown.

NF63-CV 3P 20A

NF-MB Type MCCB for MITSUBISHI Circuit Breakers Protection: Specification Table

Frame A303250100
Circuit Breakers ModelNF32-SVNF63-CVNF63-SVNF-125-SV
Number of Poles33333
Rated Insulation Voltage Ui (V)500500500500500
Rated
Short
Circuit
Breaking
Capacity
(kA)


JIS C 8201-2-1 Ann.1
JIS C 8201-2-1 Ann.2
IEC 60947-2
EN 60947-2
(Icu/Ics)
AC440 V2.5/2.52.5/2.52.5/2.57.5/7.525/25
415 V2.5/2.52.5/2.52.5/2.57.5/7.530/30
400 V5/55/55/57.5/7.530/30
380 V5/55/55/57.5/7.530/30
230 V7.5/7.57.5/7.57.5/7.515/1550/50
GB 14048.2
(Icu/Ics)
AC415 V2.5/2.52.5/2.52.5/2.57.5/7.530/30
400 V5/55/55/57.5/7.530/30
380 V5/55/55/57.5/7.530/30
230 V7.5/7.57.5/7.57.5/7.515/1550/50
NK
(Icu/Ics)
AC450 V2.5/2.52.5/2.52.5/2.57.5/7.525/25
240 V7.5/7.57.5/7.57.5/7.515/1550/50
Rated Impulse Withstand Voltage Uimp (kV)88888
Circuit Breakers Current TypeACACACACAC
Isolation CompatibilityCompatibleCompatibleCompatibleCompatibleCompatible
Reverse ConnectionPossiblePossiblePossiblePossiblePossible
Open-close Lifespan (Cycles)Mechanical10,00010,00010,00015,00025,000
Electrical (440 V AC)6,0006,0006,0008,00010,000
Selectability Type (Usage Category)AAAAA
Degree of Contamination33333
EMC Environmental Conditions (Environment A or Environment B)N/AN/AN/AN/AN/A
External
Dimensions
(mm)

a7575757590
b130130130130130
c6868686868
ca9090909090
Product Weight of Front Surface Type (kg)0.650.650.650.71.0
Electrical Appliance and Material Safety ActCompatibleCompatibleCompatibleCompatibleCompatible
CE MarkSelf-declaredSelf-declaredSelf-declaredSelf-declaredSelf-declared
CCC CertificationCertifiedCertifiedCertifiedCertifiedCertified
Classification Society Certification (✓ = Acquired) (NK, LR, ABS, DNV/GL)
Overcurrent Tripping MethodThermal - electromagneticThermal - electromagneticThermal - electromagneticThermal - electromagneticThermal - electromagnetic
Trip Button

Note 1: The rated capacity applicable to the motor is not stated on the Circuit Breakers. It should be selected according to the full-load current of the motor.
Note 2: Please specify "FP-LT" for flush type with lead terminal block.
Note 3: Please specify "P-LT" for plug-in type with lead terminal block.

External Dimensions of Circuit Breakers

External dimensions

Rated Capacity for MITSUBISHI Circuit Breakers

Circuit Breakers NF32-SV (Frame A: 30)

A200/220 V400/440 V
kWkW
255.511
163.77.5
12-5.5
102.2-
8-3.7
7.11.5-
5-2.2
40.751.5

Circuit Breakers NF63-CV

A200/220 V400/440 V
kWkW
451122
40-18.5
327.515
255.511
163.77.5
12-5.5
102.2-
8-3.7

Circuit Breakers NF32-SV (Frame A: 32)

A200/220 V400/440 V
kWkW
327.515

Circuit Breakers NF63-SV

A200/220 V400/440 V
kWkW
7.11.5-
5-2.2
40.751.5

Circuit Breakers NF125-SV

A200/220 V400/440 V
kWkW
100-55
902245
7118.537
631530
451122
(40)-19
327.515
(25)5.511
(16)3.77.5
(12.5)-5.5

Rated current: A
Rated capacity for Circuit Breakers: kW
Standard ambient temperature: 40°C (45°C for ships)

Part Number
NF63-CV 3P 20A
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSAmpere frame Rated block capacity AC 200 V
(kA)
Rated block capacity AC 400 V
(kA)
Rated Braking Capacity at Rated Voltage of VDC 250
(kA)
Number of Poles Rated Current
(A)
Representative Standard Dimension height
(mm)
Dimension width
(mm)
Format

-

1 Piece(s) Quote 650AF-52.5320PSE / CE / CCC13075Economical Products

Loading...

  1. 1
 

Basic Information

Mounting Method DIN/Screw retention Connection Method Surface type Dimension depth(mm) 90

Please check the type/dimensions/specifications of the part NF63-CV 3P 20A in the Molded Case Circuit Breakers (MCCB) NF-CV/SV series.

Products like this...

Part Number
NF32-SV 3P 32A MB
NF32-SV 3P 5A MB
NF63-CV 2P 10A
NF63-CV 3P 30A
NF63-CV 3P 40A
NF63-CV 3P 50A
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSAmpere frame Rated block capacity AC 200 V
(kA)
Rated block capacity AC 400 V
(kA)
Rated Braking Capacity at Rated Voltage of VDC 250
(kA)
Number of Poles Rated Current
(A)
Representative Standard Dimension height
(mm)
Dimension width
(mm)
Format

-

1 Piece(s) Quote 632AF-5-332CE / PSE / CCC13075General-Purpose Product

-

1 Piece(s) Quote 630AF-5-35CE / PSE / CCC13075General-Purpose Product

-

1 Piece(s) Quote 650AF-52.5210CE / PSE / CCC13050Economical Products

-

1 Piece(s) Quote 650AF-52.5330CE / PSE / CCC13075Economical Products

-

1 Piece(s) Quote 650AF-52.5340CE / PSE / CCC13075Economical Products

MYR 317.42

1 Piece(s) Quote 650AF-52.5350CE / PSE / CCC13075Economical Products

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)