Molded Case Circuit Breakers (MCCB) NF-HRV Series

Molded Case Circuit Breakers (MCCB) NF-HRV Series

- MCCB (Molded Case Circuit Breakers) High performance class NF-HRV series from Mitsubishi electric. - Frame size is 50. - No. of pole can be select 2 or 3 poles. - Applicable for both AC/DC. - Rated ambient temperature 40°C. - Rated current can be select up to 50 A. - Rated insulation voltage (Ui) is 690 V - Mechanical duration (On/Off) is up to 25,000 times. - Electrical duration (On/Off) is up to 10,000 times. - Possible to reverse connection.

PDF

Part Number

Configured Part Number is shown.

NF63-HV 3P 10A

MITSUBISHI Circuit Breakers Specifications of MCCB

MITSUBISHI Circuit Breakers Specifications of NF63-HV

Type Name Circuit BreakersNF63-HV Circuit Breakers
Rated current In A
Standard ambient temperature 40°C (45°C for marine)
10 15 20 30 40 50
Number of Positions234
Rated Insulation Voltage Ui V690
Rated short circuit breaking capacity kAJIS C 8201-2-1
Ann.1
JIS C 8201-2-1
Ann.2
IEC 60947-2
EN 60947-2
(Icu/Ics)
AC690 V2.5/2.5
500 V7.5/7.5
440 V10/8
415 V10/8
400 V10/8
380 V10/8
230 V25/19
DC250 V (*1)7.5/7.5
GB 14048.2
(Icu/Ics)
AC415 V10/8
400 V10/8
380 V10/8
230 V25/19
DC250 V7.5/7.5
NK
(Icu/Ics)
AC450 V10/8-
240 V25/19-
DC250 V7.5/7.5-

*: Circuit Breakers For 3-position and 4-position products, use 2 positions.

Internal equipment of NF63-HV

Internal equipment of NF63-HV

Temperature correction curve of NF63-HV

Temperature correction curve of NF63-HV

MITSUBISHI Circuit Breakers NF63-HRV/NF125-HV Specifications

Type Name Circuit BreakersNF63-HRV Circuit BreakersNF125-HV Circuit Breakers
Rated current In A
Standard ambient temperature 40°C (45°C for marine)
15 20 30 40 5015 20 30 40 50
Number of Positions23234
Rated Insulation Voltage Ui V690690
Rated short circuit breaking capacity kAJIS C 8201-2-1
Ann.1
JIS C 8201-2-1
Ann.2
IEC 60947-2
EN 60947-2
(Icu/Ics)
AC690 V2.5/110/8
500 V20/1030/23
440 V30/1550/38
415 V30/1550/38
400 V30/1550/38
380 V30/1550/38
230 V85/43100/75
DC250 V (*1)40/20-
GB 14048.2
(Icu/Ics)
AC415 V-50/38
400 V-50/38
380 V-50/38
230 V-100/75
DC250 V--
NK
(Icu/Ics)
AC450 V30/1550/38-
240 V85/43100/75-
DC250 V40/20--
Parts included as standard
(Surface type)
Mounting screw M4 × 0.7 × 55 (2, 3-position 2 pcs., 4-position 4 pcs.)
(*2) Insulation barrier (2-position 1 pc., 3-position 2 pcs., 4-position 3 pcs.)

*1: Circuit Breakers For 3-position and 4-position products, use 2 positions. In that case, do not use the neutral pole of the 4-position product. Also, if you connect as shown in the figure, you can use up to 400 V DC for3-position products and 500 V DC for 4-position products. Please refer to the catalog for more details.
*2: It is attached to NF63-HRV and NF125-HV.

Internal equipment of NF63-HRV/NF125-HV

Internal equipment of NF63-HRV/NF125-HV

* Circuit Breakers For 2-position products of NF63-HRV and NF125-HV, refer to the number of mounting of 3-position products.

Temperature correction curve of NF63-HRV/NF125-HV

Temperature correction curve of NF63-HRV/NF125-HV

MITSUBISHI Circuit Breakers NF125-HEV Specifications

Type Name Circuit BreakersNF125-HEV Circuit Breakers
Rated current In A
Standard ambient temperature 40°C
50
Number of Positions34
Rated Insulation Voltage Ui V690
Rated short circuit breaking capacity kAJIS C 8201-2-1
Ann.1
JIS C 8201-2-1
Ann.2
IEC 60947-2
EN 60947-2
(Icu/Ics)
AC690 V10/8
500 V50/38
440 V65/65
415 V70/70
400 V75/75
380 V75/75
230 V100/100
DC250 V-
GB 14048.2
(Icu/Ics)
AC415 V70/70
400 V75/75
380 V75/75
230 V100/100
DC250 V-
NK
(Icu/Ics)
AC450 V-
240 V-
DC250 V-
Parts included as standard
(Surface type)
Circuit Breakers, Mounting screw M4 × 0.7 × 55 (3-position 2 pcs., 4-position 4 pcs.)
Insulation barrier (3-position 4 pcs., 4-position 6 pcs.)
Internal equipment of NF125-HEV

Internal equipment of NF125-HEV

(*) SLT is included from the standard. A control power supply (100 to 240 V AC/DC) is required.

 

Current reduction curve of NF125-HEV

*Please refer to the catalog for any information not listed above.

Part Number
NF63-HV 3P 10A
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHS

MYR 575.18

1 Piece(s) 9 Day(s) or more 6

Loading...

  1. 1
 

Basic Information

Ampere frame 50AF Rated block capacity AC 200 V(kA) 25 Rated block capacity AC 400 V(kA) 10
Rated Braking Capacity at Rated Voltage of VDC 250(kA) 7.5 Number of Poles 3 Rated Current(A) 10
Mounting Method DIN/Screw retention Connection Method Surface type Representative Standard PSE / CE / CCC
Dimension height(mm) 130 Dimension width(mm) 75 Dimension depth(mm) 90
Format High Performance Products

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)