(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
· Molded Case Circuit Breakers (MCCB) NF-CV/SV series from MITSUBISHI.
· Rated Current Range: 3.4A to 63A (varies by model)
· Number of Poles: 2, 3, or 4 (model-dependent)
· Rated Insulation Voltage: 500V or 600V (model-dependent)
· Rated Short-Circuit Breaking Capacity: AC voltages: 230V to 690V, DC voltage: 250V (for some models)
· Short-Circuit Breaking Capacity Range: 2.5/2.5 kA to 75/75 kA (varies by voltage and model)
· Standard Attached Parts: Terminal screw: M5×14, Mounting screw: M4×0.7×55 and Insulation barrier
Part Number
Configured Part Number is shown.
NF32-SV 3P 32A MB
| Frame A | 30 | 32 | 50 | 100 | ||||
|---|---|---|---|---|---|---|---|---|
| Circuit Breakers Model | NF32-SV | NF63-CV | NF63-SV | NF-125-SV | ||||
| Number of Poles | 3 | 3 | 3 | 3 | 3 | |||
| Rated Insulation Voltage Ui (V) | 500 | 500 | 500 | 500 | 500 | |||
| Rated Short Circuit Breaking Capacity (kA) | JIS C 8201-2-1 Ann.1 JIS C 8201-2-1 Ann.2 IEC 60947-2 EN 60947-2 (Icu/Ics) | AC | 440 V | 2.5/2.5 | 2.5/2.5 | 2.5/2.5 | 7.5/7.5 | 25/25 |
| 415 V | 2.5/2.5 | 2.5/2.5 | 2.5/2.5 | 7.5/7.5 | 30/30 | |||
| 400 V | 5/5 | 5/5 | 5/5 | 7.5/7.5 | 30/30 | |||
| 380 V | 5/5 | 5/5 | 5/5 | 7.5/7.5 | 30/30 | |||
| 230 V | 7.5/7.5 | 7.5/7.5 | 7.5/7.5 | 15/15 | 50/50 | |||
| GB 14048.2 (Icu/Ics) | AC | 415 V | 2.5/2.5 | 2.5/2.5 | 2.5/2.5 | 7.5/7.5 | 30/30 | |
| 400 V | 5/5 | 5/5 | 5/5 | 7.5/7.5 | 30/30 | |||
| 380 V | 5/5 | 5/5 | 5/5 | 7.5/7.5 | 30/30 | |||
| 230 V | 7.5/7.5 | 7.5/7.5 | 7.5/7.5 | 15/15 | 50/50 | |||
| NK (Icu/Ics) | AC | 450 V | 2.5/2.5 | 2.5/2.5 | 2.5/2.5 | 7.5/7.5 | 25/25 | |
| 240 V | 7.5/7.5 | 7.5/7.5 | 7.5/7.5 | 15/15 | 50/50 | |||
| Rated Impulse Withstand Voltage Uimp (kV) | 8 | 8 | 8 | 8 | 8 | |||
| Circuit Breakers Current Type | AC | AC | AC | AC | AC | |||
| Isolation Compatibility | Compatible | Compatible | Compatible | Compatible | Compatible | |||
| Reverse Connection | Possible | Possible | Possible | Possible | Possible | |||
| Open-close Lifespan (Cycles) | Mechanical | 10,000 | 10,000 | 10,000 | 15,000 | 25,000 | ||
| Electrical (440 V AC) | 6,000 | 6,000 | 6,000 | 8,000 | 10,000 | |||
| Selectability Type (Usage Category) | A | A | A | A | A | |||
| Degree of Contamination | 3 | 3 | 3 | 3 | 3 | |||
| EMC Environmental Conditions (Environment A or Environment B) | N/A | N/A | N/A | N/A | N/A | |||
| External Dimensions (mm) | a | 75 | 75 | 75 | 75 | 90 | ||
| b | 130 | 130 | 130 | 130 | 130 | |||
| c | 68 | 68 | 68 | 68 | 68 | |||
| ca | 90 | 90 | 90 | 90 | 90 | |||
| Product Weight of Front Surface Type (kg) | 0.65 | 0.65 | 0.65 | 0.7 | 1.0 | |||
| Electrical Appliance and Material Safety Act | Compatible | Compatible | Compatible | Compatible | Compatible | |||
| CE Mark | Self-declared | Self-declared | Self-declared | Self-declared | Self-declared | |||
| CCC Certification | Certified | Certified | Certified | Certified | Certified | |||
| Classification Society Certification (✓ = Acquired) (NK, LR, ABS, DNV/GL) | ✓ | ✓ | ✓ | ✓ | ✓ | |||
| Overcurrent Tripping Method | Thermal - electromagnetic | Thermal - electromagnetic | Thermal - electromagnetic | Thermal - electromagnetic | Thermal - electromagnetic | |||
| Trip Button | ✓ | ✓ | ✓ | ✓ | ✓ | |||
Note 1: The rated capacity applicable to the motor is not stated on the Circuit Breakers. It should be selected according to the full-load current of the motor.
Note 2: Please specify "FP-LT" for flush type with lead terminal block.
Note 3: Please specify "P-LT" for plug-in type with lead terminal block.

| A | 200/220 V | 400/440 V |
|---|---|---|
| kW | kW | |
| 25 | 5.5 | 11 |
| 16 | 3.7 | 7.5 |
| 12 | - | 5.5 |
| 10 | 2.2 | - |
| 8 | - | 3.7 |
| 7.1 | 1.5 | - |
| 5 | - | 2.2 |
| 4 | 0.75 | 1.5 |
| A | 200/220 V | 400/440 V |
|---|---|---|
| kW | kW | |
| 45 | 11 | 22 |
| 40 | - | 18.5 |
| 32 | 7.5 | 15 |
| 25 | 5.5 | 11 |
| 16 | 3.7 | 7.5 |
| 12 | - | 5.5 |
| 10 | 2.2 | - |
| 8 | - | 3.7 |
| A | 200/220 V | 400/440 V |
|---|---|---|
| kW | kW | |
| 32 | 7.5 | 15 |
| A | 200/220 V | 400/440 V |
|---|---|---|
| kW | kW | |
| 7.1 | 1.5 | - |
| 5 | - | 2.2 |
| 4 | 0.75 | 1.5 |
| A | 200/220 V | 400/440 V |
|---|---|---|
| kW | kW | |
| 100 | - | 55 |
| 90 | 22 | 45 |
| 71 | 18.5 | 37 |
| 63 | 15 | 30 |
| 45 | 11 | 22 |
| (40) | - | 19 |
| 32 | 7.5 | 15 |
| (25) | 5.5 | 11 |
| (16) | 3.7 | 7.5 |
| (12.5) | - | 5.5 |
Rated current: A
Rated capacity for Circuit Breakers: kW
Standard ambient temperature: 40°C (45°C for ships)
| Part Number |
|---|
| NF32-SV 3P 32A MB |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Ampere frame | Rated block capacity AC 200 V (kA) | Rated block capacity AC 400 V (kA) | Rated Braking Capacity at Rated Voltage of VDC 250 (kA) | Number of Poles | Rated Current (A) | Representative Standard | Dimension height (mm) | Dimension width (mm) | Format |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 6 | 32AF | - | 5 | - | 3 | 32 | PSE / CE / CCC | 130 | 75 | General-Purpose Product |
Loading...
| Mounting Method | DIN/Screw retention | Connection Method | Surface type | Dimension depth(mm) | 90 |
|---|
Please check the type/dimensions/specifications of the part NF32-SV 3P 32A MB in the Molded Case Circuit Breakers (MCCB) NF-CV/SV series.
| Part Number |
|---|
| NF125-CV 3P 50A |
| NF32-SV 3P 10A MB |
| NF32-SV 3P 25A MB |
| NF32-SV 3P 5A MB |
| NF63-CV 2P 10A |
| NF63-CV 2P 15A |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Ampere frame | Rated block capacity AC 200 V (kA) | Rated block capacity AC 400 V (kA) | Rated Braking Capacity at Rated Voltage of VDC 250 (kA) | Number of Poles | Rated Current (A) | Representative Standard | Dimension height (mm) | Dimension width (mm) | Format |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 6 | [100AF to 199AF] 100AF | 30 | 10 | 7.5 | 3 | 50 | PSE / CCC | 130 | 90 | Economical Products | ||
- | 1 Piece(s) | Quote | 6 | 30AF | - | 5 | - | 3 | 10 | CE / PSE / CCC | 130 | 75 | General-Purpose Product | ||
- | 1 Piece(s) | Quote | 6 | 30AF | - | 5 | - | 3 | 25 | CE / PSE / CCC | 130 | 75 | General-Purpose Product | ||
- | 1 Piece(s) | Quote | 6 | 30AF | - | 5 | - | 3 | 5 | CE / PSE / CCC | 130 | 75 | General-Purpose Product | ||
- | 1 Piece(s) | Quote | 6 | 50AF | - | 5 | 2.5 | 2 | 10 | CE / PSE / CCC | 130 | 50 | Economical Products | ||
- | 1 Piece(s) | Quote | 6 | 50AF | - | 5 | 2.5 | 2 | 15 | CE / PSE / CCC | 130 | 50 | Economical Products |



MITSUBISHI
Days to Ship : 16 Day(s) or more





MITSUBISHI
Days to Ship : Quote


MITSUBISHI
Standard Price : MYR 575.18
Days to Ship : 9 Day(s) or more
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy