(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

Insulation Cap for CW Series (Part Numbers)

Insulation Cap  for CW Series

Insulation cap for CW-type low voltage current transformers.
[Features]
· Can be attached with the crimp terminal attached.
· To ensure that the entire terminals are insulated, there is no exposed charging section.
· Features a dedicated insulation cap that matches the shape of the product so that there is almost no change in product height after attaching them.
· Semi-transparent, thus the insulation attachment can be checked while attached.
[Applications]
· Low voltage current transformer cap.

(i)Caution

  • Some products are scheduled to be discontinued from October 2021. Depend on stock status, the end time will be changed. Please check the quotation and order screen for details.

Part Number

Configured Part Number is shown.

Features of Insulation Cap For CW-type Low Voltage Current Transformers

Can be attached with the crimp terminal attached.
To ensure that the entire terminals are insulated, there is no exposed charging section.
Features a dedicated insulation cap that matches the shape of the product so that there is almost no change in product height after attaching them.
Semi-transparent, thus the insulation attachment can be checked while attached.

Type Name

Type NameCompatible Models
CW-M1CW-L, LP, LM, LS, LMS type CT secondary terminals of 2,000 A or less
CW-M2CW-LP, LS type primary CT terminals
CW-M3CW-40LM, 15LMS 2,500 to 4,000 A secondary terminals

Compatible Model List

CT Type NameRatedInsulation CapNotes
CW-M1CW-M2CW-M3
CW-5L
60 to 750 A
2--Secondary terminals
CW-15L
100 to 750 A
2--"
CW-40L
150 to 750 A
2--"
CW-5LP
1 to 50 A
22-Use for primary and secondary terminals
CW-15LP
1 to 50 A
22-"
CW-40LP
1 to 50 A
22-"
CW-15LM
150 to 750 A
2--Secondary terminals
CW-40LM, 15LMS
200 to 2,000 A
2--"
CW-40LM, 15LMS
2,500 to 4,000 A
--2"
CW-15LM
1,500 to 4,000 A
--2"
CW-15LS
5 to 30 A
22-Use for primary and secondary terminals
CW-15LS40 to 750 A2--Secondary terminals

External Dimensional Diagram For Insulation Cap For CW-Type Low Voltage Current Transformers

CW-M1

CW-M1

CW-M2

CW-M2

CW-M3

CW-M3

Part Number
CW-M1
CW-M2
CW-M3
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSQuantity of units ordered
(Piece)
Applicable current transformer Note

MYR 8.28

100 Piece(s) 3 Day(s) or more 6100CW-40L / CW-40LM / CW-40LP / CW-15L / CW-15LM / CW-15LMS / CW-15LP / CW-15LS / CW-5L / CW-5LPSecondary terminal of CW-L, LP, LM, LS, LMS type CT 2000 A or less, unit ordered: 100

MYR 11.04

100 Piece(s) 31 Day(s) or more 6100CW-40LP / CW-15LP / CW-15LS / CW-5LPPrimary terminal of CW-LP, LS type CT, units ordered: 100

-

1 Piece(s) Quote 6-CW-40LM / CW-15LM / CW-15LMSSecondary terminal of CW-40LM, 15LMS 2500 to 4000 A, unit ordered: 100

Loading...

  1. 1

Basic Information

Specifications Semi-Transparent

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)