· Ethernet connectivity: Both modules enable easy connection of FX3 series PLCs to Ethernet networks for enhanced communication and control.
· FX3U-ENET-L allows the read/write of sequence programs from/to FX3U/FX3UC PLCs via Ethernet.
· FX3U-ENET-ADP provides remote monitoring and the ability to change programs, improving maintenance efficiency.
· Buffer memory (FX3U-ENET-L): Facilitates communication with other PLCs or devices using fixed buffers.
· E-mail functionality (FX3U-ENET-L): Allows sending e-mails directly from the PLC.
· Easy setup: Both modules offer simple Ethernet configuration via dedicated PC tools.
· Compatibility: FX3U-ENET-ADP works with a wide range of FX3 series modules.
Part Number
Configured Part Number is shown.

FX3U-ENET-ADP Image
| Transmission Specifications | Data Transmission Speed | 100 Mbps or 10 Mbps |
|---|---|---|
| Communication Mode | Full-duplex / half-duplex | |
| Transmission Method | Baseband | |
| Maximum Segment Length | 100 m | |
| Maximum Number of Nodes/Connections | 10BASE-T: Up to 4 cascade connection levels 100BASE-TX: Up to 2 cascade connection levels The above is the number of connectable levels when using a repeater hub. For the number of connectable levels when using a switching hub, check with the manufacturer of the switching hub to be used. | |
| Applicable Connector | RJ45 | |
| Function | · MELSOFT connection · Communication using MC protocol · Direct connection with MELSOFT (easy connection) · Connected CPU search function · Time setting function *Time setting function (SNTP client) can be executed only after the trigger condition is met · Diagnostic function from MELSOFT · Data monitoring function | |
| Number of Connections | MELSOFT connection + MC protocol + data monitoring ≤ 4 connections | |
| Number of Connectable Unit to Base Unit | One Ethernet adapter occupies one communication channel (CH), as n communication function expansion board or other special communication adapters do. | |
| Applicable Sequencers | FX3S, FX3G (V2.00 or later), FX3U (V3.10 or later), FX3GC (V2.00 or later), FX3UC (V3.10 or later): FX3S-CNV-ADP is required to connect to the FX3S. FX3G-CNV-ADP is required to connect to the FX3G. A function expansion board is required to connect to an FX3U or FX3UC-32MT-LT (-2). | |
| Weight | 0.1 kg | |
| Power Supply Specifications | ||
| Power Supply | 30 mA / 5 V DC (Energized internally from the 5 V DC power supply of the base unit) | |
| Allowable Momentary Power Outage Duration | Same as the connected sequencer | |
| Ambient Temperature | 0 to 55°C: When operating, -25 to 75°C: When stored | ||
|---|---|---|---|
| Relative Humidity | 5 to 95% RH (non-condensing): When operating | ||
| Vibration Resistance | When Mounting to DIN Rail | Frequency: 10 to 57 Hz | Single amplitude: 0.035 mm, 10 times in each direction of X, Y and Z (total of 80 minutes each) |
| Frequency: 57 to 150 Hz | Acceleration: 4.9 m/s2 10 times in each direction of X, Y and Z (total of 80 minutes each) | ||
| When Mounting Directly | Frequency: 10 to 57 Hz | Single amplitude: 0.075 mm 10 times in each direction of X, Y and Z (total of 80 minutes each) | |
| Frequency: 57 to 150 Hz | Acceleration: 9.8 m/s2 10 times in each direction of X, Y and Z (total of 80 minutes each) | ||
| Impact Resistant | 147 m/s2, for a duration of 11 ms, 3 times in each direction of X, Y and Z with a half-sine pulse | ||
| Noise Resistance | Achieved through a noise simulator with a noise voltage of 1,000 Vp-p, noise width of 1 μs, the rise time of 1 ns and frequency of 30 to 100 Hz | ||
| Withstand Voltage | Between all terminals batch and earth terminal: 500 V AC for 1 minute | ||
| Insulation Resistance | Between all terminals batch and earth terminal: 5 MΩ or more with 500 V DC ohmmeter | ||
| Operating Atmosphere | There shall be no corrosion gas or flammable gas and not much conductive dust | ||
| Altitude of Use | 2,000 m or less Cannot be used in environments pressurized above atmospheric pressure. This may cause failure. | ||
| Part Number |
|---|
| FX3U-ENET-ADP |
| FX3U-ENET-L |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Connection Terminal | Representative Standard | Applicable sequencer | Type of unit | Communication Speed (kbps) | Transmission Speed |
|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 1,005.40 | 1 Piece(s) | 91 Day(s) | - | Connector | CE / UL / CUL | - | Ethernet interface block | 100M/10 Mbps | - | ||
MYR 2,737.87 | 1 Piece(s) | 20 Day(s) | 6 | - | CE / UL | FX3U / FX3UC | Ethernet Connection Interface | - | 10Mbps / 100Mbps |
Loading...
| Communication Interface (Transmission Standard) | Ethernet |
|---|

MITSUBISHI
Standard Price : MYR 2,278.33-
Days to Ship : 65 Day(s) or more

MITSUBISHI
Standard Price : MYR 6,421.67-
Days to Ship : 4 Day(s) or more

MITSUBISHI
Standard Price : MYR 628.33-
Days to Ship : 97 Day(s)

OMRON
Standard Price : MYR 5,748.00-
Days to Ship : 5 Day(s) or more

How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy