| Valve function | 3/2 | 5/2 | 5/3 | |||||
|---|---|---|---|---|---|---|---|---|
| Normal position | G | O | - | - | G | B | E | |
| Stable position | Monostable | Bistable | Monostable | |||||
| Reset method: pneumatic spring | Yes | - | No | |||||
| Reset method: mechanical spring | No | - | Yes | |||||
| Design | Piston spool | |||||||
| Sealing principle | Soft | |||||||
| Lap | Overlap | |||||||
| Type of actuation | Electrical | |||||||
| Type of control | Pilot | |||||||
| Pilot air supply | Internal or external | |||||||
| Flow direction | - | Reversible with external pilot air supply | ||||||
| Exhaust air function | - | With flow control | ||||||
| Manual override | Non-detenting, detenting via accessory | |||||||
| Type of mounting | Via through-holes | |||||||
| Mounting position | Any | |||||||
| Pneumatic connection | 1, 2, 4 | Threaded connection: M5, M7; QS connection: ุ 4 or ุ 6 mm | ||||||
| 3, 5 | Threaded connection: M7 | |||||||
| 12, 14 | Threaded connection: M3; QS connection: ุ 3 mm | |||||||
| 82, 84 | Threaded connection: M3 | |||||||
| Nominal width [mm] | 4 | |||||||
| Standard nominal flow rate [l/min] | M5 | 190 | 180 | |||||
| M7 | 400 | 350 | 300 | 250 | ||||
| QS4 | 190 | 180 | ||||||
| QS6 | 300 | 350 | 320 | 300 | 250 | |||
| Switching time [ms] | On/off | 14/14 | 16/20 | - | 16/20 | |||
| Changeover | - | 8 | - | |||||
| Duty cycle [%] | 100 | |||||||
| Width [mm] | 10 | |||||||
| Corrosion resistance class CRC | 2 | |||||||
| Part Number |
|---|
| CPE10-M1BH-3GL-QS-6 |
| CPE10-M1BH-3OLS-M7 |
| CPE10-M1BH-5J-QS-6 |
| CPE10-M1BH-5L-M7 |
| CPE10-M1BH-5L-QS-4 |
| CPE10-M1BH-5L-QS-6 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Pneumatic connection 1 | Pneumatic connection 2 | Pneumatic connection 4 | Pneumatic connection 5 | Pneumatic working port | Pilot exhaust air port 84 | Pilot air port 14 | Valve function | Standard nominal flow rate (l/min) | Pilot air supply port | Changeover time (ms) | Reset method | Switching time off (ms) | Switching time on (ms) | Min. Operating pressure (bar) | Max. Operating pressure (bar) | Min. Pilot pressure (bar) | Max. Pilot pressure (bar) | Pilot medium | Manufacturer part # | Weight (g) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 1,610.25 | 1 Piece(s) | Quote | QS-6 | QS-6 | - | - | QS-6 | - | - | 3/2, closed, monostable | 300 | Internal | - | Pneumatic spring | 14 | 14 | 2.5 | 8 | - | - | - | 196847 | - | ||
MYR 1,571.67 | 1 Piece(s) | Quote | M7 | M7 | - | - | M7 | - | - | 3/2, open, monostable | 400 | External | - | Pneumatic spring | 14 | 14 | -0.9 | 10 | 2.5 | 8 | Compressed air as per ISO 8573-1:2010 [7:4:4] | 196918 | 40 | ||
MYR 2,338.05 | 1 Piece(s) | Quote | QS-6 | QS-6 | QS-6 | M7 | QS-6 | M3 | M3 | 5/2, bistable | 320 | Internal | 8 | - | - | - | 2.5 | 8 | - | - | - | 196877 | - | ||
MYR 1,609.45 | 1 Piece(s) | Quote | M7 | M7 | M7 | M7 | M7 | M3 | M3 | 5/2, monostable | 350 | Internal | - | Pneumatic spring | 20 | 16 | 3 | 8 | - | - | - | 196927 | 56 | ||
MYR 1,728.58 | 1 Piece(s) | Quote | QS-4 | QS-4 | QS-4 | M7 | QS-4 | M3 | M3 | 5/2, monostable | 180 | Internal | - | Pneumatic spring | 20 | 16 | 3 | 8 | - | - | - | 196882 | - | ||
MYR 1,742.11 | 1 Piece(s) | Quote | QS-6 | QS-6 | QS-6 | M7 | QS-6 | M3 | M3 | 5/2, monostable | 320 | Internal | - | Pneumatic spring | 20 | 16 | 3 | 8 | - | - | - | 196883 | - |
Loading...
| Housing material | Die-cast aluminum | Seals material | NBR | Pneumatic connection 3 | M7 |
|---|---|---|---|---|---|
| Pilot exhaust air port 82 | M3 | Pilot air port 12 | M3 | Degree of protection | IP65 |
| Lap | Overlap | Width(mm) | 10 | Nominal width(mm) | 4 |
| Flow direction | Non-reversible | Operating voltage(V) | 24 DC | Min. Temperature of medium(°C) | -5 |
| Max. Temperature of medium(°C) | 50 | Min. Ambient temperature(°C) | -5 | Max. Ambient temperature(°C) | 50 |
| Max. positive test pulse with 0 signal(µs) | 1200 | Max. negative test pulse on 1 signal(µs) | 900 | Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] |
| Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy