Part Number
Configured Part Number is shown.
E-MSM2DFA-K1
| Mechanical locking / electromagnetic release | After the operating key is inserted, the contacts of the safety control circuit close (normally closed contacts), and the operating key is automatically locked by the mechanical locking mechanism and cannot be removed. After the internal electromagnet is powered, the mechanical locking mechanism is released, allowing the operation key to be removed normally. Once the operation key is removed, the contacts of the safety control circuit open. |
| Electromagnetic Locking / Mechanical Release | After the operation key is inserted, it can still be removed normally at this time. Only when the internal electromagnet is powered will the operation key be locked and cannot be removed, and the contacts of the safety control circuit will close (normally closed contacts). When the internal electromagnet is powered off, the electromagnetic locking mechanism is released, and the operating key can be removed. |
| Even when the internal electromagnet is powered on, the lock can be released by turning the mechanical lock knob from the LOCK position to the UNLOCK position using a release tool. At this point, the operating key can also be removed normally. After the operating key is removed, the contacts of the safety control circuit are disconnected. |

| Compliance standards | IEC61508 SIL2 TUV EN 60947-5-1:2017 | |
| Material | PA66 flame retardant | |
| Mechanical life | Over 1,000,000 cycles | |
| Electrical life | Over 150,000 cycles (240 V AC 3 A, resistive load) | |
| Type of use | AC-15 | DC-13 |
| Rated operational voltage (Ue) | 240V | 24V |
| Rated operational current (Ie) | 3A | 2A |
| Electromagnetic coil | ||
| Rated operational voltage | DC24V | |
| Power | 4.8W | |
| Rated current | Approx. 200 mA | |
| Insulation | Class B (130°C) | |
| LED indicator | ||
| Rated operational voltage | DC24V | |
| Rated current | Approx. 2 mA | |
| Emitting color (LED) | Green | |
| Environment | ||
| Operating ambient temperature | -10°C to +55°C, no freezing | |
| Operating ambient humidity | 95% RH or less | |
| Electrical | ||
| Contact resistance | 200 mΩ or less | |
| Rated open thermal current (Ith) | 10A | |
| Rated insulation voltage (Ui) | 300V | |
| Electric shock protection class | Class II (double insulation) | |
| Impulse withstand voltage (EN60947-5-1) | 2.5 kV | |
| Insulation resistance | 100 MΩ or more | |
| Short-circuit protection device | Requires a quick-blow fuse, 10 A, 250 V | |
| Vibration resistance | 10-55Hz, double amplitude 1.5 mm | |
| Shock resistance | Durability 1000 m/s2 | |
| Conditional short-circuit current | 100A | |
| Contact gap | 2 x 2 mm or more | |
| Operating characteristics | ||
| Pre-travel for positive opening | 10 mm or more | |
| Operating speed | 0.1 m to 0.5 m/s | |
| Permissible operating frequency | Maximum 30 operations per minute | |
| Pull-out strength when locked | 1300N | |

| Including operating key model | Safety door lock model | Operating key model | Contact Type | Locking Method | Material | Door lock holding force | Rated Operating Voltage/Current | Safety Level |
| E-MSM2AFG-K1 | E-MSM2AFG | 1NC/1NO+1NC/1NO | 24 V DC Electromagnetic Locking/Mechanical Release | Safety Door Lock Material: PA66 Operating Key | 1300N | 24 V DC, 200 mA | IEC61508 SIL2 TUV 60947-5-1:2017 | |
| E-MSM2AFA-K1 | E-MSM2AFA | T Shape ![]() E-MSMD2-K1 | Mechanical Locking/24 V DC Electromagnetic Release | |||||
| E-MSM2CFG-K1 | E-MSM2CFG | 2NC+1NC/1NO | 24 V DC Electromagnetic Locking/Mechanical Release | |||||
| E-MSM2DFG-K1 | E-MSM2DFG | 2NC+2NC | ||||||
| E-MSM2DFA-K1 | E-MSM2DFA | Mechanical Locking/24 V DC Electromagnetic Release | ||||||
| E-MSM2TFG-K1 | E-MSM2TFG | 3NC+1NC | 24 V DC Electromagnetic Locking/Mechanical Release | |||||
| E-MSM2OFG-K1 | E-MSM2OFG | 1NC+3NC | ||||||
| E-MSM2AFG-K2 | E-MSM2AFG | 1NC/1NO+1NC/1NO | 24 V DC Electromagnetic Locking/Mechanical Release | |||||
| E-MSM2AFA-K2 | E-MSM2AFA | L Shape ![]() E-MSMD2-K2 | Mechanical Locking/24 V DC Electromagnetic Release | |||||
| E-MSM2CFG-K2 | E-MSM2CFG | 2NC+1NC/1NO | 24 V DC Electromagnetic Locking/Mechanical Release | |||||
| E-MSM2DFG-K2 | E-MSM2DFG | 2NC+2NC | ||||||
| E-MSM2DFA-K2 | E-MSM2DFA | Mechanical Locking/24 V DC Electromagnetic Release | ||||||
| E-MSM2TFG-K2 | E-MSM2TFG | 3NC+1NC | 24 V DC Electromagnetic Locking/Mechanical Release | |||||
| E-MSM2OFG-K2 | E-MSM2OFG | 1NC+3NC | Mechanical Locking/24 V DC Electromagnetic Release |


· Do not wire the switch while it is powered on. Otherwise, electric shock may occur.
· When wiring, do not allow small wires or other fine particles to enter the switch body.
· When connecting terminals using an insulating tube or M3.0 crimp terminals, make sure they are not pressed against the housing or cover.
· Applicable wire size: AWG20 to AWG18 (0.5 to 0.75 mm). Use wires of appropriate length for wiring. Otherwise, the cover may bulge or may not be properly secured.
· Do not insert crimp terminals into the gaps of the housing, as this may cause damage or deformation of the housing.
· To prevent the terminal from contacting the inside of the switch housing, use terminals with a thickness of less than 0.5 mm.
| Model | Contact Type | Contact Form | Operation Mode | ||
| Door Monitoring | Lock Monitoring | ■ Contact ON | □ Contact OFF | ||
![]() ![]() | ![]() | ||||
| E-MSM2AFG | 1NC/1NO+1NC/1NO | ![]() | ![]() | ||
| E-MSM2AFA | |||||
| E-MSM2CFG | 2NC+1NC/1NO | ![]() | ![]() | ||
| E-MSM2DFA | 2NC+2NC | ![]() | ![]() | ||
| E-MSM2DFG | |||||
| E-MSM2TFG | 3NC+1NC | ![]() | ![]() | ||
| E-MSM2OFG | 1NC+3NC | ![]() | ![]() | ||

| Contact configuration For example: 2NC+1NC/NO | Factory state (key not inserted) | Door closed state (key inserted) | Door closed state (key inserted and locked) | Door open state (key removed) | Manual unlocking - perform unlocking![]() |
| Contact change status | ![]() | ![]() | ![]() | ![]() | ![]() |
| Electromagnetic coil status | Power off | Power off | Power on | Power off | Power off |
| Manual unlock knob status | ![]() | ![]() | ![]() | ![]() | ![]() |
| Safety door status | Open | Closed | Closed | Open | Closed |
| Note | Door is open Equipment cannot operate Electromagnet is de-energized | Door is closed Equipment cannot operate Electromagnet is de-energized | Door is closed Equipment is operating Electromagnet is energized | Door is open Equipment cannot operate Electromagnet is de-energized | Door is closed Equipment cannot operate Do not perform manual unlocking while powered on. Do not keep the coil energized for a long time when the door is open or in the unlocked position. |

| Contact configuration For example: 2NC+1NC/NO | Factory state (key not inserted) | Door closed state (key inserted and locked) | Door unlocked state (key inserted) | Door open state (key removed) | Manual unlocking - perform unlocking![]() |
| Contact change status | ![]() | ![]() | ![]() | ![]() | ![]() |
| Electromagnetic coil status | Power off | Power off | Power on | Power off | Power off |
| Manual unlock knob status | ![]() | ![]() | ![]() | ![]() | ![]() |
| Safety door status | Open | Closed | Closed | Open | Closed |
| Note | Door is open Equipment cannot operate Electromagnet is de-energized | Door is closed Equipment is operating Electromagnet is de-energized | Door is closed and unlocked Equipment cannot operate Electromagnet is energized | Door is open Equipment cannot operate Electromagnet is de-energized | Door is closed Equipment cannot operate Electromagnet is de-energized |
Note: When the operation key is inserted, it is locked by the force of the spring. Therefore, it remains locked during a power outage and unlocks when the solenoid coil is energized. In an emergency, manual unlocking is also possible (turn to the UNLOCK position with a Phillips screwdriver).



CAD Data download and 3D preview are not available because the part number has not yet been determined.
| Part Number |
|---|
| E-MSM2DFA-K1 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Mechanical Life (10,000 times) | Mechanical Operation Frequency (times/min or Less) | Contact Type | Locking Method | Operating Key | Usage Method | Operating Key Material |
|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 324.18 | 1 Piece(s) | Available | 6 Day(s) | - | - | 2NC+2NC | Mechanical locking / 24 V DC electromagnetic release | E-MSMD2-K1 (horizontal installation) | Electromagnetic / mechanical door lock, operating key kit | SUS201 |
Loading...
| Rated Operating Voltage(V) | DC24V | Rated operating current(A) | 200 mA | Safety Door Lock Conduit Port Size | M20 × 1.5 waterproof connector |
|---|---|---|---|---|---|
| Safety Door Lock Head Material | PA66 | Safety Door Lock Body Material | PA66 | Safety Door Lock Locking Force | 1300N |
Please check the type/dimensions/specifications of the part E-MSM2DFA-K1 in the Safety Locking Door Switches series.
| Part Number |
|---|
| E-MSM2AFG |
| E-MSM2AFG-K1 |
| E-MSM2AFG-K2 |
| E-MSM2DFA-K2 |
| E-MSM2DFG |
| E-MSM2DFG-K1 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Mechanical Life (10,000 times) | Mechanical Operation Frequency (times/min or Less) | Contact Type | Locking Method | Operating Key | Usage Method | Operating Key Material |
|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 319.12 | 1 Piece(s) | Available | 6 Day(s) | Over 1 million times | 30 | 1NC/1NO+1NC/1NO | 24 V DC electromagnetic locking / mechanical release | - | Electromagnetic / mechanical locking | - | |
MYR 324.18 | 1 Piece(s) | Available | 6 Day(s) | - | - | 1NC/1NO+1NC/1NO | 24 V DC electromagnetic locking / mechanical release | E-MSMD2-K1 (horizontal installation) | Electromagnetic / mechanical door lock, operating key kit | SUS201 | |
MYR 324.18 | 1 Piece(s) | Available | 6 Day(s) | - | - | 1NC/1NO+1NC/1NO | 24 V DC electromagnetic locking / mechanical release | E-MSMD2-K2 (vertical installation) | Electromagnetic / mechanical door lock, operating key kit | SUS201 | |
MYR 324.18 | 1 Piece(s) | Available | 6 Day(s) | - | - | 2NC+2NC | Mechanical locking / 24 V DC electromagnetic release | E-MSMD2-K2 (vertical installation) | Electromagnetic / mechanical door lock, operating key kit | SUS201 | |
MYR 316.38 | 1 Piece(s) | Available | 6 Day(s) | Over 1 million times | 30 | 2NC+2NC | 24 V DC electromagnetic locking / mechanical release | - | Electromagnetic / mechanical locking | - | |
MYR 324.18 | 1 Piece(s) | Available | 6 Day(s) | - | - | 2NC+2NC | 24 V DC electromagnetic locking / mechanical release | E-MSMD2-K1 (horizontal installation) | Electromagnetic / mechanical door lock, operating key kit | SUS201 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy