(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

Safety Locking Door Switches (E-MSM2DFG)

Safety Locking Door Switches E-MSM2DFG
  • Economy
  • Volume Discount

TUV Certificate>>Click
ECM SIL2 Certificate>>Click

Product Overview
The E-MSM2 series safety door locks are the most commonly used door interlock technology. They use a key installed at the switch opening to detect the movement of the safety door. With their compact and lightweight design, diverse contact configurations, and locking function, safety door locks are usually the most cost-effective solution. In addition, the use of flexible keys increases their misalignment tolerance, making them suitable for a wide range of applications. The E-MSM2 series safety door locks allow the switch head to be rotated four times at 90° angles, the key can be inserted into the switch in seven different positions, and the solenoid can be set to operate with power on or power off. This provides a variety of options for the switch’s operating modes and installation methods on protective doors. This increases the flexibility of the switch, making it suitable for use on various types of doors.
◆ Built-in multiple contact structure options;
◆ Locking force of 1300N;
◆ IP67 protection rating;
◆ Housing made of PA66 flame-retardant material;
◆ Suitable for general or micro loads.

■ Locking method description
Mechanical locking / electromagnetic releaseAfter the operating key is inserted, the contacts of the safety control circuit close (normally closed contacts), and the operating key is automatically locked by the mechanical locking mechanism and cannot be removed.
After the internal electromagnet is powered, the mechanical locking mechanism is released, allowing the operation key to be removed normally. Once the operation key is removed, the contacts of the safety control circuit open.
Electromagnetic Locking / Mechanical ReleaseAfter the operation key is inserted, it can still be removed normally at this time. Only when the internal electromagnet is powered will the operation key be locked and cannot be removed, and the contacts of the safety control circuit will close (normally closed contacts).
When the internal electromagnet is powered off, the electromagnetic locking mechanism is released, and the operating key can be removed.
Even when the internal electromagnet is powered on, the lock can be released by turning the mechanical lock knob from the LOCK position to the UNLOCK position using a release tool. At this point, the operating key can also be removed normally. After the operating key is removed, the contacts of the safety control circuit are disconnected.
Dimensional Drawing
★ Rear unlock key not provided
Specification Overview
■ Technical Parameters
Compliance standardsIEC61508 SIL2
TUV EN 60947-5-1:2017
MaterialPA66 flame retardant
Mechanical lifeOver 1,000,000 cycles
Electrical lifeOver 150,000 cycles
(240 V AC 3 A, resistive load)
Type of useAC-15DC-13
Rated operational voltage (Ue)240V24V
Rated operational current (Ie)3A2A
Electromagnetic coil
Rated operational voltageDC24V
Power4.8W
Rated currentApprox. 200 mA
InsulationClass B (130°C)
LED indicator
Rated operational voltageDC24V
Rated currentApprox. 2 mA
Emitting color (LED)Green
Environment
Operating ambient temperature-10°C to +55°C, no freezing
Operating ambient humidity95% RH or less
 
Electrical
Contact resistance200 mΩ or less
Rated open thermal current (Ith)10A
Rated insulation voltage (Ui)300V
Electric shock protection classClass II (double insulation)
Impulse withstand voltage
(EN60947-5-1)
2.5 kV
Insulation resistance100 MΩ or more
Short-circuit protection deviceRequires a quick-blow fuse, 10 A, 250 V
Vibration resistance10-55Hz, double amplitude 1.5 mm
Shock resistanceDurability 1000 m/s2
Conditional short-circuit current100A
Contact gap2 x 2 mm or more
Operating characteristics
Pre-travel for positive opening10 mm or more
Operating speed0.1 m to 0.5 m/s
Permissible operating frequencyMaximum 30 operations per minute
Pull-out strength when locked1300N
 
Specification Table
Including operating key modelSafety door lock modelOperating key modelContact TypeLocking MethodMaterialDoor lock holding forceRated Operating Voltage/CurrentSafety Level
E-MSM2AFG-K1E-MSM2AFG 1NC/1NO+1NC/1NO24 V DC Electromagnetic Locking/Mechanical ReleaseSafety Door Lock
Material: PA66

Operating Key
1300N24 V DC, 200 mAIEC61508 SIL2
 
TUV 60947-5-1:2017
E-MSM2AFA-K1E-MSM2AFA
T Shape
Specification Overview
E-MSMD2-K1
Mechanical Locking/24 V DC Electromagnetic Release
E-MSM2CFG-K1E-MSM2CFG2NC+1NC/1NO24 V DC Electromagnetic Locking/Mechanical Release
E-MSM2DFG-K1E-MSM2DFG2NC+2NC
E-MSM2DFA-K1E-MSM2DFAMechanical Locking/24 V DC Electromagnetic Release
E-MSM2TFG-K1E-MSM2TFG3NC+1NC24 V DC Electromagnetic Locking/Mechanical Release
E-MSM2OFG-K1E-MSM2OFG1NC+3NC
E-MSM2AFG-K2E-MSM2AFG 1NC/1NO+1NC/1NO24 V DC Electromagnetic Locking/Mechanical Release
E-MSM2AFA-K2E-MSM2AFA
L Shape

Specification Overview
E-MSMD2-K2
Mechanical Locking/24 V DC Electromagnetic Release
E-MSM2CFG-K2E-MSM2CFG2NC+1NC/1NO24 V DC Electromagnetic Locking/Mechanical Release
E-MSM2DFG-K2E-MSM2DFG2NC+2NC
E-MSM2DFA-K2E-MSM2DFAMechanical Locking/24 V DC Electromagnetic Release
E-MSM2TFG-K2E-MSM2TFG3NC+1NC24 V DC Electromagnetic Locking/Mechanical Release
E-MSM2OFG-K2E-MSM2OFG1NC+3NCMechanical Locking/24 V DC Electromagnetic Release
Product Features
■ Wiring diagram
Inside the top of the door

Internal Wiring Diagram of Door Lock

Door lock structure

Internal Wiring Diagram of Door Lock

Wiring method

· Do not wire the switch while it is powered on. Otherwise, electric shock may occur.
· When wiring, do not allow small wires or other fine particles to enter the switch body.
· When connecting terminals using an insulating tube or M3.0 crimp terminals, make sure they are not pressed against the housing or cover.
· Applicable wire size: AWG20 to AWG18 (0.5 to 0.75 mm). Use wires of appropriate length for wiring. Otherwise, the cover may bulge or may not be properly secured.
· Do not insert crimp terminals into the gaps of the housing, as this may cause damage or deformation of the housing.
· To prevent the terminal from contacting the inside of the switch housing, use terminals with a thickness of less than 0.5 mm.

 
Contact Structure and Operation
ModelContact TypeContact FormOperation Mode
Door MonitoringLock Monitoring■ Contact ON□ Contact OFF
Contact FormContact FormOperation Mode
E-MSM2AFG1NC/1NO+1NC/1NOContact Form
E-MSM2AFA
E-MSM2CFG2NC+1NC/1NOContact Form
E-MSM2DFA2NC+2NCContact Form
E-MSM2DFG
E-MSM2TFG3NC+1NCContact Form
E-MSM2OFG1NC+3NC
 
Operating characteristics
·Electromagnetic locking, mechanical release
Electromagnetic Locking Mechanical Release
Contact configuration
For example: 2NC+1NC/NO
Factory state
(key not inserted)
Door closed state
(key inserted)
Door closed state
(key inserted and locked)
Door open state
(key removed)
Manual unlocking - perform unlocking
Manual unlock knob status
Contact change statusContact change statusContact change statusContact change statusContact change statusContact change status
Electromagnetic coil statusPower offPower offPower onPower offPower off
Manual unlock knob statusManual unlock knob statusManual unlock knob statusManual unlock knob statusManual unlock knob statusManual unlock knob status
Safety door statusOpenClosedClosedOpenClosed
NoteDoor is open
Equipment cannot operate
Electromagnet is de-energized
Door is closed
Equipment cannot operate
Electromagnet is de-energized
Door is closed
Equipment is operating
Electromagnet is energized
Door is open
Equipment cannot operate
Electromagnet is de-energized
Door is closed
Equipment cannot operate
Do not perform manual unlocking while powered on.
Do not keep the coil energized for a long time when the door is open or in the unlocked position.
Note: When there is a power outage or the electromagnetic coil is de-energized, inserting the operation key will not lock the door. Therefore, the door can be opened for operation. When locked by the energized solenoid coil, the door will not be locked in the event of an emergency or sudden power outage. Therefore, this model is not suitable for situations where hazardous conditions may still exist inside the equipment.
Electromagnetic/mechanical door lock with operation key kit model.

·Mechanical locking, electromagnetic release
Mechanical locking, electromagnetic release
Contact configuration
For example: 2NC+1NC/NO
Factory state
(key not inserted)
Door closed state
(key inserted and locked)
Door unlocked state
(key inserted)
Door open state
(key removed)
Manual unlocking - perform unlocking
Manual unlock knob status
Contact change statusContact change statusContact change statusContact change statusContact change statusContact change status
Electromagnetic coil statusPower offPower offPower onPower offPower off
Manual unlock knob statusManual unlock knob statusManual unlock knob statusManual unlock knob statusManual unlock knob statusManual unlock knob status
Safety door statusOpenClosedClosedOpenClosed
NoteDoor is open
Equipment cannot operate
Electromagnet is de-energized
Door is closed
Equipment is operating
Electromagnet is de-energized
Door is closed and unlocked
Equipment cannot operate
Electromagnet is energized
Door is open
Equipment cannot operate
Electromagnet is de-energized
Door is closed
Equipment cannot operate
Electromagnet is de-energized

Note: When the operation key is inserted, it is locked by the force of the spring. Therefore, it remains locked during a power outage and unlocks when the solenoid coil is energized. In an emergency, manual unlocking is also possible (turn to the UNLOCK position with a Phillips screwdriver).

Usage Method
■ Combined use with safety door latch
(Latch model: E-MSMSKF10-LK)
 
Installation on right-side movable door
1. Use six M6*16 mm screws to secure the latch base
2. Use two M5*16 mm screws to secure the key adapter
3. Use four M4*34 mm countersunk screws to secure the safety door lock
4. Use two M6*16 mm screws to secure the door lock base
5. Use two M4*8 mm fixing screws to secure the door lock key
Installation on left-side movable door
1. Use 6 M6*16 mm screws to secure the latch base
2. Use 2 M5*16 mm screws to secure the key adapter
3. Use 4 M4*34 mm countersunk screws to secure the safety door lock
4. Use 2 M6*16 mm screws to secure the door lock base
5. Use 2 M4*8 mm fixing screws to secure the door lock key

 
■ Installation method for the stopper base
During installation, please be careful not to drop the product from a height. Otherwise, it may cause personal injury.
Do not use the main unit as a stopper. Be sure to install the stopper as shown in the diagram to prevent the flange of the operating key from hitting the head.

Part Number 

CAD Data download and 3D preview are not available because the part number has not yet been determined.

  • *In order to open the CAD Data download and 3D preview screen, the part number must be fixed.
  • Please confirm the part number from "Specification / Dimension"on the left side, and then perform the CAD Data Download / 3D Preview operation.
Loading...
Part Number
E-MSM2DFG
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipMechanical Life
(10,000 times)
Mechanical Operation Frequency
(times/min or Less)
Contact Type Locking Method Operating Key Usage Method Operating Key Material

MYR 316.38

1 Piece(s)Available 6 Day(s) Over 1 million times302NC+2NC24 V DC electromagnetic locking / mechanical release-Electromagnetic / mechanical locking-

Loading...

  1. 1

Basic Information

Rated Operating Voltage(V) DC24V Rated operating current(A) 200 mA Safety Door Lock Conduit Port Size M20 × 1.5 waterproof connector
Safety Door Lock Head Material PA66 Safety Door Lock Body Material PA66 Safety Door Lock Locking Force 1300N

Please check the type/dimensions/specifications of the part E-MSM2DFG in the Safety Locking Door Switches series.

Products like this...

Part Number
E-MSM2AFG
E-MSM2AFG-K1
E-MSM2AFG-K2
E-MSM2DFG-K1
E-MSM2DFG-K2
E-MSM2OFG
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipMechanical Life
(10,000 times)
Mechanical Operation Frequency
(times/min or Less)
Contact Type Locking Method Operating Key Usage Method Operating Key Material

MYR 319.12

1 Piece(s)Available 6 Day(s) Over 1 million times301NC/1NO+1NC/1NO24 V DC electromagnetic locking / mechanical release-Electromagnetic / mechanical locking-

MYR 324.18

1 Piece(s)Available 6 Day(s) --1NC/1NO+1NC/1NO24 V DC electromagnetic locking / mechanical releaseE-MSMD2-K1 (horizontal installation)Electromagnetic / mechanical door lock, operating key kitSUS201

MYR 324.18

1 Piece(s)Available 6 Day(s) --1NC/1NO+1NC/1NO24 V DC electromagnetic locking / mechanical releaseE-MSMD2-K2 (vertical installation)Electromagnetic / mechanical door lock, operating key kitSUS201

MYR 324.18

1 Piece(s)Available 6 Day(s) --2NC+2NC24 V DC electromagnetic locking / mechanical releaseE-MSMD2-K1 (horizontal installation)Electromagnetic / mechanical door lock, operating key kitSUS201

MYR 324.18

1 Piece(s)Available 6 Day(s) --2NC+2NC24 V DC electromagnetic locking / mechanical releaseE-MSMD2-K2 (vertical installation)Electromagnetic / mechanical door lock, operating key kitSUS201

MYR 319.12

1 Piece(s)Available 6 Day(s) Over 1 million times301NC+3NC24 V DC electromagnetic locking / mechanical release-Electromagnetic / mechanical locking-

Additional Products in this Category

Tech Support