(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

Area Sensor, Plastic Housing Type

Area Sensor, Plastic Housing Type

Click this image to zoom it.

Move the mouse over the image to zoom

  • Volume Discount

This is an economy item, The price is cheaper than the MISUMI standard product.

Product Overview
 
Economy Resin Case Ultra-Thin Area Sensor
Front-emitting, space-saving design, only 13 mm thick. Easy to align with light. Light-resistant, strong electromagnetic interference resistance, low power consumption design for faster response time.
 
Dimensional Drawing
 
■ Product Drawings (Unit: mm)

Floodlight

Economy Plastic Area Sensor

Economy Plastic Area Sensor

Part numberABCD
E-MSM-N6(P6)10013014026
E-MSM-N8(P8)14018019052
E-MSM-N12(P12)22026027084
E-MSM-N16(P16)300340350124
 
 
Specification Overview
 
Part Number-Number of Optical Axes-Output Type
E-MSMN-6-N
 
Part NumberNumber of ShaftsOutput TypeDetection Height H (mm)Total Height L (mm)
Type
E-MSMN6 to 16N(NPN Output) /
P(PNP Output)
100 to 300140 to 350
 
TypeNumber of Optical AxesOutput TypeDetection Height (mm)Total height (mm)
HL
E-MSMN6NPN: N
PNP: P
100140
8140190
12220270
16300350
 
 
■ Specifications and Performance
ItemTypesShaft Spacing (20 mm)
Part numberNPN OutputE-MSMN6-NE-MSMN8-NE-MSMN12-NE-MSMN16-N
PNP OutputE-MSMN6-PE-MSMN8-PE-MSMN12-PE-MSMN16-P
Output ActionAll beams ON when light passes through (OFF when one or more beams are blocked) Normally Closed
Number of Shafts6-Axis8-Axis12 Axes16 Axes
Detection Height100 mm140 mm220 mm300 mm
Detection Distance4 m
Shaft Spacing20 m
Object DetectionOpaque objects with a diameter of 30 mm or more (completely light-blocking objects)
Operating Voltage12 to 24 V DC ±10% Ripple P-P less than 10%
Control Output
<NPN Output Type>
NPN Open Collector Transistor
● Maximum Input Current: 100 mA
● Applied Voltage: 30 V DC or less (between output and 0 V)
● Residual Voltage: 1 V or less (at input current 100 mA)
  0.4 V or less (at input current 16 mA)
<PNP Output Type>
PNP Open Collector Transistor
● Maximum Input Current:
● Applied voltage: 30 V DC or less (between output and +V)
●Residual voltage: 1 V or less (at 100 mA input current)
  0.4 V or less (at 16 mA input current)
Circuit protectionSurge protection circuit, short-circuit protection, reverse polarity protection
Response TimeBelow 10 ms (below 12 ms when using anti-interference function)
Indicator LampFloodlightEmission Indicator Light: Green LED ×2 (Lights up during emission; 1 LED lights up when frequency A is set, 2 LEDs light up when frequency B is set)
Operation Indicator Light: Red LED (When using the operation indicator input, it lights up, blinks, or turns off; the lighting mode is selected by the operation mode switch)
ReceiverOperating Status Indicator: Red LED (lights up when one or more optical axes are interrupted)
Stable Light Received Indicator: Green LED (lights up when all optical axes are stably received)
Operation Indicator: Red LED (lights up, flashes, or turns off when the operation indicator input is used; the lighting mode is selected by the operation mode switch)
*When the output current is excessive, both the stable light indicator and the operation status indicator on the receiver will flash simultaneously due to the operation of the short-circuit protection circuit.
Practical FunctionsEquipped with anti-interference function and emission stop function
Operating environment temperature-10 to +55°C (no freezing, no condensation), storage: -10 to +60°C
Operating environment humidity35 to 85%RH, storage: 35 to 85%RH
Operating environment illuminanceIncandescent lamp: Illuminance on the receiving surface is below 3000LX
Maximum Voltage1000 V AC 1 minute Between all power connection terminals and the enclosure
Insulation ResistanceOver 20MΩ (500 V DC megohmmeter) between charging section and enclosure
Vibration (Durability)10 to 55 Hz, 1.5 mm double amplitude, 2h in X, Y, and Z directions
Impact (Durability)500 m/s2 double amplitude, 3 times in each of the X, Y, and Z directions
Light Emitting ElementInfrared LED (Peak Emission Wavelength: 870 nm, Modulated Type)
MaterialHousing: Heat-resistant ABS, Front Cover: Polyester, Display Cover: Acrylic
Cable0.2 mm2 4-core rubber cable, length 3 m
Connection MethodLead Wire Type

■ Output Circuit Diagram
NPN Output
NPN Output

 

PNP Output
Floodlight Wire Diameter
Floodlight Wire Diameter
Receiver Cable Diameter 

 

Receiver Cable Diameter
PNP Output 

 

No.Wire ColorTransmitterReceiverWiring
1Brown+24 V+24 VPower Supply+
2Blue0V0VPower Supply-
3OrangeCommunicationCommunicationTransmitter and Receiver Interconnection
4BlackNot ProvidedNormally ClosedPLC Input Terminal
5PinkInput
(Optional)
Not ProvidedNPNPower Supply-
PNPPower Supply+
Note: 1) When the 4th operation mode selector switch on the projector is set to OFF, the input (pink) is for the work indicator lamp; when the switch is set to ON, it is for the projector stop input.
2) To use the work indicator light as a large work status display light, connect the input (pink) on the projector to the output (black) on the receiver.
3) When the projector stop input is set, the work indicator light will not turn on or will flash.
 
 Product Features
 
· Ultra-thin size, overall dimensions are only 39*15 mm
· Short response time, fastest response time <1 ms
· Wide voltage supply DC24±20%
· Strong anti-electromagnetic interference capability, effectively resists various electromagnetic interference from motor equipment
· Uses line synchronization technology, strong resistance to light interference
· Easy installation, simple operation
 
 
■About Installation
Use M4 screws with washers and M4 nuts. The tightening torque should be below 0.5N⋅m.
Do not forcefully bend or twist the sensor during installation.
(Please prepare screws and nuts separately.)
About installation

■User Guide
(1) About Debugging and Usage
(1) Names and Functions of Each Component
Correct Mounting Method

● Work Mode Selector Switch
No.NameOFF SideON Side
1Projection Frequency ConversionFrequency AFrequency B
2Work Indicator Light Mode Selector SwitchLights up when enteringTurns off when input
3Work Indicator Light Mode Selector SwitchContinuous LightingBlink
4Work Indicator Light / Projector Stop SwitchWork Indicator Light InputStop Light Input

(2) Work Indicator Light Operation Selection
● The operation of the work indicator light can be used as a mode selection switch for the work indicator light.

Work Indicator Light Mode Selector SwitchWork Indicator Light Operation
NPN Output TypePNP Output TypeNPN Output TypePNP Output Type
Operation indicator input: LowOperation indicator input: HighOperation indicator input: HighOperation indicator input: Low
Work Indicator Light Operation SelectionLight upWork Indicator Light Operation SelectionOffWork Indicator Light Operation Selection
Work Indicator Light Operation SelectionOffWork Indicator Light Operation SelectionLight upWork Indicator Light Operation Selection
Work Indicator Light Operation SelectionLight upWork Indicator Light Operation SelectionBlinkWork Indicator Light Operation Selection
Work Indicator Light Operation SelectionOffWork Indicator Light Operation SelectionBlinkWork Indicator Light Operation Selection

Work Indicator Light Input Signal Conditions

OutputSignalSignal Conditions
NPN Output TypeLow0 to 2 V
High5 to 30 V or open circuit (If open circuit, please insulate the wire)
PNP Output TypeLow0 to 2 V or open circuit (If open circuit, please insulate the wire)
High8 V~+V

● When using the work indicator light as a large work status indicator
By setting the 4th operation mode switch to the OFF position and connecting the input (pink) on the emitter to the output (black) on the receiver, the work indicator light can be used as a large work status indicator.

Work Indicator Light Operation Mode SwitchWhen Light EntersWhen not illuminated
When using the task indicator light as a large work status indicatorLight upWhen using the task indicator light as a large work status indicatorOffWhen using the task indicator light as a large work status indicator
When using the task indicator light as a large work status indicatorOffWhen using the task indicator light as a large work status indicatorLight upWhen using the task indicator light as a large work status indicator
When using the task indicator light as a large work status indicatorLight upWhen using the task indicator light as a large work status indicatorBlinkWhen using the task indicator light as a large work status indicator
When using the task indicator light as a large work status indicatorOffWhen using the task indicator light as a large work status indicatorBlinkWhen using the task indicator light as a large work status indicator

(Note 1): If you use the operation indicator as a large work status indicator, please make sure to set the 4th operation mode switch to the OFF position. If it is set to ON, the operation indicator will not light up or flash.

● Emission Stop Function
When the 4th operation mode switch is set to ON and the input (pink) on the emitter is High (PNP output type: Low), emission stops. Since the output can be set to ON/OFF when there is no detected object, this function can be used for initial detection. It can be determined as normal when the output tracks the ON/OFF input according to the light projection. If it does not track, it can be determined as a sensor abnormality.

Work Mode Switch Setting

OFFON
Work Mode Switch SettingWork Mode Switch Setting
 

(3) Anti-interference function
Since different emission frequencies are set, two sets of sensors can be installed close to each other as shown below. You can check the projection frequency by the number of LEDs lit on the projector indicator.

Anti-interference Function

 Operating Mode Switch StatusFloodlight Display Lamp
(Floodlight)
Sensor AFrequency AAnti-interference Function    Anti-interference Function1 LED lights up
Sensor B    Anti-interference FunctionFrequency BAnti-interference FunctionTwo LEDs are lit
 

(2) About Optical Axis Adjustment
a) Place the emitter and receiver facing each other in a straight line.
b) After properly connecting the cables, turn on the power.
c) Move the transmitter up, down, left, and right, and use the operation status indicator (red) to determine the light receiving range. Then, set the transmitter at the center of this range.
d) Move the transmitter up, down, left, and right in terms of angle, and adjust in the same way as above.
e) Adjust the receiver angle in the same way.
f) Check if the stable light indicator (green) is on.
g) Block the optical axis with the actual object to be detected and confirm if it is working properly.

About Shaft Adjustment 

Part Number 

CAD Data download and 3D preview are not available because the part number has not yet been determined.

  • *In order to open the CAD Data download and 3D preview screen, the part number must be fixed.
  • Please confirm the part number from "Specification / Dimension"on the left side, and then perform the CAD Data Download / 3D Preview operation.
Loading...
Part Number
E-MSMN6-N
E-MSMN6-P
E-MSMN8-N
E-MSMN8-P
E-MSMN12-N
E-MSMN12-P
E-MSMN16-N
E-MSMN16-P
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOutput Mode Detection Height
(mm)
Total Height
(mm)
Number of Optical Axes

MYR 166.33

1 Piece(s)Available 1 Day(s) NPN1001406

MYR 166.33

1 Piece(s)Available 6 Day(s) PNP1001406

MYR 186.53

1 Piece(s)Available 6 Day(s) NPN1401908

MYR 186.53

1 Piece(s)Available 6 Day(s) PNP1401908

MYR 247.01

1 Piece(s)Available 6 Day(s) NPN22027012

MYR 247.01

1 Piece(s)Available 6 Day(s) PNP22027012

MYR 280.61

1 Piece(s)Available 6 Day(s) NPN30035016

MYR 280.61

1 Piece(s)Available 6 Day(s) PNP30035016

Loading...

  1. 1

Basic Information

Operating Ambient Temperature(°C) :: -10 Operating Ambient Humidity(%) +55:: Detection Distance(mm) 4 m
Light Pitch(mm) 20 Response Speed 10 ms or Less Mounting Thread M4X4

Frequently asked question (FAQ)

Question: Does this product have a safety certification?
Answer: This device must not be used as a safety machine device; doing so may result in death or serious personal injury.
Question: What are the main features of area sensors?
Answer: 1. Non-contact type (no movable or contact parts, long lifespan)
2. Can accurately detect objects
3. Easy installation and maintenance
4. Scanning operation prevents mutual interference, ensuring high reliability
5. Area (surface) detection provides higher detection accuracy compared to single-beam type
6. Versatile, reducing design time
Question: Can area sensors detect the size of a workpiece?
Answer: Can only roughly detect the presence or absence of a workpiece; cannot determine size or specifications

Additional Products in this Category

Tech Support