(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
This is an economy item, The price is cheaper than the MISUMI standard product.
Part Number
Configured Part Number is shown.
E-MSMN16-N
Floodlight


| Part number | A | B | C | D |
| E-MSM-N6(P6) | 100 | 130 | 140 | 26 |
| E-MSM-N8(P8) | 140 | 180 | 190 | 52 |
| E-MSM-N12(P12) | 220 | 260 | 270 | 84 |
| E-MSM-N16(P16) | 300 | 340 | 350 | 124 |
| Part Number | - | Number of Optical Axes | - | Output Type |
| E-MSMN | - | 6 | - | N |
| Part Number | Number of Shafts | Output Type | Detection Height H (mm) | Total Height L (mm) | |
Type | |||||
| E-MSMN | 6 to 16 | N(NPN Output) / P(PNP Output) | 100 to 300 | 140 to 350 | |
| Type | Number of Optical Axes | Output Type | Detection Height (mm) | Total height (mm) |
| H | L | |||
| E-MSMN | 6 | NPN: N PNP: P | 100 | 140 |
| 8 | 140 | 190 | ||
| 12 | 220 | 270 | ||
| 16 | 300 | 350 |
| Item | Types | Shaft Spacing (20 mm) | ||||
| Part number | NPN Output | E-MSMN6-N | E-MSMN8-N | E-MSMN12-N | E-MSMN16-N | |
| PNP Output | E-MSMN6-P | E-MSMN8-P | E-MSMN12-P | E-MSMN16-P | ||
| Output Action | All beams ON when light passes through (OFF when one or more beams are blocked) Normally Closed | |||||
| Number of Shafts | 6-Axis | 8-Axis | 12 Axes | 16 Axes | ||
| Detection Height | 100 mm | 140 mm | 220 mm | 300 mm | ||
| Detection Distance | 4 m | |||||
| Shaft Spacing | 20 m | |||||
| Object Detection | Opaque objects with a diameter of 30 mm or more (completely light-blocking objects) | |||||
| Operating Voltage | 12 to 24 V DC ±10% Ripple P-P less than 10% | |||||
| Control Output | <NPN Output Type> NPN Open Collector Transistor ● Maximum Input Current: 100 mA ● Applied Voltage: 30 V DC or less (between output and 0 V) ● Residual Voltage: 1 V or less (at input current 100 mA) 0.4 V or less (at input current 16 mA) <PNP Output Type> PNP Open Collector Transistor ● Maximum Input Current: ● Applied voltage: 30 V DC or less (between output and +V) ●Residual voltage: 1 V or less (at 100 mA input current) 0.4 V or less (at 16 mA input current) | |||||
| Circuit protection | Surge protection circuit, short-circuit protection, reverse polarity protection | |||||
| Response Time | Below 10 ms (below 12 ms when using anti-interference function) | |||||
| Indicator Lamp | Floodlight | Emission Indicator Light: Green LED ×2 (Lights up during emission; 1 LED lights up when frequency A is set, 2 LEDs light up when frequency B is set) Operation Indicator Light: Red LED (When using the operation indicator input, it lights up, blinks, or turns off; the lighting mode is selected by the operation mode switch) | ||||
| Receiver | Operating Status Indicator: Red LED (lights up when one or more optical axes are interrupted) Stable Light Received Indicator: Green LED (lights up when all optical axes are stably received) Operation Indicator: Red LED (lights up, flashes, or turns off when the operation indicator input is used; the lighting mode is selected by the operation mode switch) *When the output current is excessive, both the stable light indicator and the operation status indicator on the receiver will flash simultaneously due to the operation of the short-circuit protection circuit. | |||||
| Practical Functions | Equipped with anti-interference function and emission stop function | |||||
| Operating environment temperature | -10 to +55°C (no freezing, no condensation), storage: -10 to +60°C | |||||
| Operating environment humidity | 35 to 85%RH, storage: 35 to 85%RH | |||||
| Operating environment illuminance | Incandescent lamp: Illuminance on the receiving surface is below 3000LX | |||||
| Maximum Voltage | 1000 V AC 1 minute Between all power connection terminals and the enclosure | |||||
| Insulation Resistance | Over 20MΩ (500 V DC megohmmeter) between charging section and enclosure | |||||
| Vibration (Durability) | 10 to 55 Hz, 1.5 mm double amplitude, 2h in X, Y, and Z directions | |||||
| Impact (Durability) | 500 m/s2 double amplitude, 3 times in each of the X, Y, and Z directions | |||||
| Light Emitting Element | Infrared LED (Peak Emission Wavelength: 870 nm, Modulated Type) | |||||
| Material | Housing: Heat-resistant ABS, Front Cover: Polyester, Display Cover: Acrylic | |||||
| Cable | 0.2 mm2 4-core rubber cable, length 3 m | |||||
| Connection Method | Lead Wire Type | |||||


| No. | Name | OFF Side | ON Side |
| 1 | Projection Frequency Conversion | Frequency A | Frequency B |
| 2 | Work Indicator Light Mode Selector Switch | Lights up when entering | Turns off when input |
| 3 | Work Indicator Light Mode Selector Switch | Continuous Lighting | Blink |
| 4 | Work Indicator Light / Projector Stop Switch | Work Indicator Light Input | Stop Light Input |
(2) Work Indicator Light Operation Selection
● The operation of the work indicator light can be used as a mode selection switch for the work indicator light.
| Work Indicator Light Mode Selector Switch | Work Indicator Light Operation | |||
| NPN Output Type | PNP Output Type | NPN Output Type | PNP Output Type | |
| Operation indicator input: Low | Operation indicator input: High | Operation indicator input: High | Operation indicator input: Low | |
![]() | Light up![]() | Off![]() | ||
![]() | Off![]() | Light up![]() | ||
![]() | Light up![]() | Blink![]() | ||
![]() | Off![]() | Blink![]() | ||
Work Indicator Light Input Signal Conditions
| Output | Signal | Signal Conditions |
| NPN Output Type | Low | 0 to 2 V |
| High | 5 to 30 V or open circuit (If open circuit, please insulate the wire) | |
| PNP Output Type | Low | 0 to 2 V or open circuit (If open circuit, please insulate the wire) |
| High | 8 V~+V |
● When using the work indicator light as a large work status indicator
By setting the 4th operation mode switch to the OFF position and connecting the input (pink) on the emitter to the output (black) on the receiver, the work indicator light can be used as a large work status indicator.
| Work Indicator Light Operation Mode Switch | When Light Enters | When not illuminated |
![]() | Light up![]() | Off![]() |
![]() | Off![]() | Light up![]() |
![]() | Light up![]() | Blink![]() |
![]() | Off![]() | Blink![]() |
(Note 1): If you use the operation indicator as a large work status indicator, please make sure to set the 4th operation mode switch to the OFF position. If it is set to ON, the operation indicator will not light up or flash.
● Emission Stop Function
When the 4th operation mode switch is set to ON and the input (pink) on the emitter is High (PNP output type: Low), emission stops. Since the output can be set to ON/OFF when there is no detected object, this function can be used for initial detection. It can be determined as normal when the output tracks the ON/OFF input according to the light projection. If it does not track, it can be determined as a sensor abnormality.
Work Mode Switch Setting
| OFF | ON |
![]() | ![]() |
(3) Anti-interference function
Since different emission frequencies are set, two sets of sensors can be installed close to each other as shown below. You can check the projection frequency by the number of LEDs lit on the projector indicator.

| Operating Mode Switch Status | Floodlight Display Lamp (Floodlight) | |
| Sensor A | Frequency A | 1 LED lights up |
| Sensor B | Frequency B | Two LEDs are lit |
(2) About Optical Axis Adjustment
a) Place the emitter and receiver facing each other in a straight line.
b) After properly connecting the cables, turn on the power.
c) Move the transmitter up, down, left, and right, and use the operation status indicator (red) to determine the light receiving range. Then, set the transmitter at the center of this range.
d) Move the transmitter up, down, left, and right in terms of angle, and adjust in the same way as above.
e) Adjust the receiver angle in the same way.
f) Check if the stable light indicator (green) is on.
g) Block the optical axis with the actual object to be detected and confirm if it is working properly.
CAD Data download and 3D preview are not available because the part number has not yet been determined.
| Operating Ambient Temperature(°C) | :: -10 | Operating Ambient Humidity(%) | +55:: | Detection Distance(mm) | 4 m |
|---|---|---|---|---|---|
| Light Pitch(mm) | 20 | Response Speed | 10 ms or Less | Mounting Thread | M4X4 |
Please check the type/dimensions/specifications of the part E-MSMN16-N in the Area Sensor, Plastic Housing Type series.
| Part Number |
|---|
| E-MSMN12-N |
| E-MSMN12-P |
| E-MSMN16-P |
| E-MSMN6-N |
| E-MSMN6-P |
| E-MSMN8-N |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Output Mode | Detection Height (mm) | Total Height (mm) | Number of Optical Axes |
|---|---|---|---|---|---|---|---|---|
MYR 247.01 | 1 Piece(s) | Available | 6 Day(s) | NPN | 220 | 270 | 12 | |
MYR 247.01 | 1 Piece(s) | Available | 6 Day(s) | PNP | 220 | 270 | 12 | |
MYR 280.61 | 1 Piece(s) | Available | 6 Day(s) | PNP | 300 | 350 | 16 | |
MYR 166.33 | 1 Piece(s) | Available | 1 Day(s) | NPN | 100 | 140 | 6 | |
MYR 166.33 | 1 Piece(s) | Available | 6 Day(s) | PNP | 100 | 140 | 6 | |
MYR 186.53 | 1 Piece(s) | Available | 6 Day(s) | NPN | 140 | 190 | 8 |
How can we improve?