SMC
Refrigerated air dryer for high-temperature environments.
[Features]
· Ambient temperature: Up to 45°C.
· Inlet air temperature: Up to 60°C.
· Energy-saving design.
· Uses a corrosion-resistant stainless steel heat exchanger that reduces exhaust heat by up to 25% to prevent the ambient temperature from rising.
· Size: 100F, 125F, 150F.
| Standard Price: | MYR 75,691.71- |
|---|---|
| Days to Ship: | 3 Day(s) or more |

Refrigerated Air Dryer, Refrigerant R407C (HFC), IDF100F/125F/150F Series
SMC
Refrigerated air dryer with energy-saving design that can be used in a high-temperature environment (ambient temperature up to 45°C).
[Features]
·Air-cooled / water-cooled
·Removes moisture from the moist compressed air sent from the compressor to prevent malfunction of pneumatic equipment due to moisture
·Air-cooling specifications and compatible with ambient temperature of 45°C
·Energy saving design: Dryer exhaust heat amount reduced by Max. 25%
·By reducing the amount of exhaust heat, it is possible to reduce the size of the air conditioner and save energy
| Standard Price: | MYR 63,008.89- |
|---|---|
| Days to Ship: | 21 Day(s) or more |

Refrigerated Air Dryer, Refrigerant R407C (HFC) Standard Temperature Air Inlet, IDF□D Series
SMC
Large refrigerated air dryer with energy-saving design.
[Features]
· Refrigerated air dryer that protects pneumatic equipment from moisture.
· Removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment to fail.
· Voltage (IDF190D-3): Three-phase: 200 V AC (50 Hz) / 200/220 V AC (60 Hz).
· Voltage (IDF190D-9): Three-phase different voltage (built-in transformer).
· Power supply voltage: 220 V / 380 V / 400 V / 415 V / 440 V.
| Standard Price: | MYR 90,702.75- |
|---|---|
| Days to Ship: | 21 Day(s) or more |

Refrigerated Air Dryer, Refrigerant R407C (HFC), IDF100FS/125FS/150FS Series
SMC
Refrigerated air dryer for high-temperature environments.
[Features]
· Double energy-saving function series that saves up to 76% energy by using a second re-heater and digital scroll compressor.
· Exhaust heat: Reduced by up to 25%.
· Ambient temperature: Up to 45°C.
· Inlet air temperature: Up to 60°C.
· ECO switch.
· Switch between energy-saving operation mode and normal operation mode depending on the season and operating environment.
· RoHS compliant.
| Standard Price: | MYR 96,237.25- |
|---|---|
| Days to Ship: | 26 Day(s) or more |
| Brand |
|---|
| Product Series |
| CAD |
| Days to Ship |
| Type |
| Method |
| Shape |
| Unit Combination |
| Outlet Flow Rate(l/min) |
| Outlet Open Air Pressure Dew-point(℃) |
| Supply Side, Connection Type |
| Inlet Air Temperature(℃) |
| Inlet Air Pressure(MPa) |
| Supply Side, Plumbing Thread Nominal |
| Supply Side, Connecting Tube Diameter |
| Supply Side, Tube Flange Nominal |
| Control Side, Connection Type |
| Control Side, Plumbing Thread Nominal |
| Control Side, Connecting Tube Diameter |
| Control Side, Tube Flange Nominal |
| Exit Flow Rate [Distinction](l/min) |
| Brand | SMC | SMC | SMC | SMC |
|---|---|---|---|---|
| Product Series | Refrigerated Air Dryer, Refrigerant R407C (HFC), IDF100F/125F/150F Series | Refrigerated Air Dryer, Refrigerant R407C (HFC) Standard Temperature Air Inlet, IDF□D Series | Refrigerated Air Dryer, Refrigerant R407C (HFC), IDF100FS/125FS/150FS Series | |
| CAD |
|
|
|
|
| Days to Ship | 3 Day(s) or more | 21 Day(s) or more | 21 Day(s) or more | 26 Day(s) or more |
| Type | Dryers | Dryers | Dryers | Dryers |
| Method | Freezing Type | Freezing Type | Freezing Type | Freezing Type |
| Shape | Standard | Standard | Standard | Standard |
| Unit Combination | - | - | - | - |
| Outlet Flow Rate(l/min) | 22,333 ~ 25,000 | 20,100 ~ 30,000 | 32,000 ~ 65,000 | 20,100 ~ 27,000 |
| Outlet Open Air Pressure Dew-point(℃) | 3 ~ 10 | 10 | 10 | 10 |
| Supply Side, Connection Type | Tube Flange | Tube Flange | Tube Flange | Tube Flange |
| Inlet Air Temperature(℃) | 35 ~ 40 | 40 | 35 ~ 40 | 40 |
| Inlet Air Pressure(MPa) | 0.7 | 0.7 | 0.7 | 0.7 |
| Supply Side, Plumbing Thread Nominal | - | - | - | - |
| Supply Side, Connecting Tube Diameter | - | - | - | - |
| Supply Side, Tube Flange Nominal | 80 | 65 / 80 | 80 / 100 / 150 | 65 / 80 |
| Control Side, Connection Type | Tube Flange | Tube Flange | Tube Flange | Tube Flange |
| Control Side, Plumbing Thread Nominal | - | - | - | - |
| Control Side, Connecting Tube Diameter | - | - | - | - |
| Control Side, Tube Flange Nominal | 80 | 65 / 80 | 80 / 100 / 150 | 65 / 80 |
| Exit Flow Rate [Distinction](l/min) | More than 5000 | More than 5000 | More than 5000 | More than 5000 |
Loading...
* ~5 represents over 1, and 5 or less.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy