(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
| Days to Ship |
|
|---|

Air Combination, Air Filter + Regulator, AC10B-A to AC40B-A
SMC
SMC modular-type F.R.L. combination unit.
[Features]
· Uses a transparent bowl guard.
· A transparent bowl guard with improved environmental resistance that provides all-round protection.
· The manufacturer has removed the window from the bowl guard and instead covered the entire internal bowl with a polycarbonate transparent bowl guard.
· Now, even if the environment changes and the bowl is exposed to corrosive chemicals or oil, the foreign matter will not stick directly to the pressurized bowl. This can help reduce the risk of the bowl breaking.
· Superior visibility: 360°
· The use of the transparent bowl guard allows you to check the status of the drain inside the filter bowl and to check the amount of residual oil in the lubricator from any angle.
· Weight reduction: reduced by up to 90 g
· Without corrosion. The use of a resin body ensures there is no rusting.
| Days to Ship: | 3 Day(s) or more |
|---|

FR Combination (Modular Type Standard) C*020 / C2520 Series
CKD
Boost your system with modularization. Dual element construction provides long life. Note: CAD data of this series is being revised. Please wait till the corrections are done.
[Features]
· Design for each F.R.I device focused on making it more compact. Assembled dimensions are accurately calculated with a simple calculation.
· Maintained strength from previous models and decreased weight by 50% (compared to C4000) by using a combination of materials (body is aluminum die cast, cover is resin).
· The elements are constructed from a unique fiber structure that is rough on the surface and becomes finer the further inward it goes (PAT.PEND). Greatly reduced clogs and greatly improved product life. No rust concerns.
· Past models had a pressure meter that stuck out of the front surface, wasting space or being at risk of striking the employees. This embedded design is both clean and an improvement to safety.
· Prevents oil drips when reverse pressure is applied such as when residual exhaust valves release pressure.
· Taking safety into further consideration, this device is equipped with a corrosive resistant plastic bowl.
· Gauge plug is sealed even here a pipe plug is not installed.
| Days to Ship: | 13 Day(s) or more |
|---|

F.R.L. Large Flow Series, F.R.L. Combination CN/CY/CZ Series
KOGANEI
A series of line-end equipment ideal for treatment performed at large flow rates. A modular type that can be selected for various applications.
| Standard Price: | MYR 714.47- |
|---|---|
| Days to Ship: | 17 Day(s) or more |

Air Combination, Air Filter + Regulator AC20B-B to AC60B-B Series
SMC
FRL unit with improved workability
[Features]
・ Improved visibility & environmental resistance
· The transparent case guard covers the entire circumference of the case.
・ 360° visual confirmation is possible.
・ Protects the case from the external environment and improves safety
・ Improved workability
・ By integrating the element and the case, the element can be replaced at hand.
· The amount of space required for maintenance has been reduced.
[20-Series Copper/Fluorine-Free Specifications]
・ Suitable for use in environments that dislike copper and fluorine materials.
・ External dimensions are the same as standard products.
| Days to Ship: | 21 Day(s) or more |
|---|

Service Units/Regulator/Filter
MISUMI
An air conditioning equipment set (FR) with an air filter and a pressure regulating valve.
| Standard Price: | MYR 525.90 |
|---|---|
| Days to Ship: | 2 Day(s) |

Air Combination, Air Filter + Regulator, ACG20B, ACG30B, ACG40B
SMC
FRL unit with improved visibility of the pressure gauge at various mounting locations.
[Features]
· Single-action installation and removal of the pressure gauge cover.·
· The mounting angle of the pressure gauge can be selected according to the piping direction.
Pressure gauge anti-revolving mechanism.
Panel-cut for pressure gauge not necessary.
· Fluid: air.
| Days to Ship: | 27 Day(s) or more |
|---|
| Brand |
|---|
| Product Series |
| CAD |
| Days to Ship |
| Regulator Unit Combination |
| Connection Dia. |
| Filter, Filtration Level |
| Compressed Air Quality |
| Max. Operating Pressure(MPa) |
| Relief Mechanism |
| Flow Direction |
| Condensate Drain |
| Pressure Gauge |
| Brand | SMC | CKD | KOGANEI | SMC | MISUMI | SMC |
|---|---|---|---|---|---|---|
| Product Series | F.R.L. Large Flow Series, F.R.L. Combination CN/CY/CZ Series | Air Combination, Air Filter + Regulator AC20B-B to AC60B-B Series | Air Combination, Air Filter + Regulator, ACG20B, ACG30B, ACG40B | |||
| CAD |
|
|
|
|
| |
| Days to Ship | 3 Day(s) or more | 13 Day(s) or more | 17 Day(s) or more | 21 Day(s) or more | 2 Day(s) | 27 Day(s) or more |
| Regulator Unit Combination | Filter + Regulator | Filter + Regulator | Filter + Regulator | Filter + Regulator | Filter + Regulator | Filter + Regulator |
| Connection Dia. | Rc1/8 / Rc1/4 / Rc3/8 / Rc1/2 / Rc3/4 / NPT1/4 / NPT3/8 / G1/4 / G3/8 / NPT1/2 / NPT3/4 / NPT1/8 / G1/8 / G1/2 / G3/4 / M5 | Rc1/8 / Rc1/4 / Rc3/8 / NPT1/4 / NPT3/8 / G1/4 / G3/8 / NPT1/8 / G1/8 | Rc3/4 / Rc1 | Rc1/8 / Rc1/4 / Rc3/8 / Rc1/2 / Rc3/4 / Rc1 / NPT1/4 / NPT3/8 / G1/4 / G3/8 / NPT1/2 / NPT3/4 / NPT1/8 / NPT1 / G1/8 / G1/2 / G3/4 / G1 | Rc1/4 | Rc1/8 / Rc1/4 / Rc3/8 / Rc1/2 / NPT1/4 / NPT3/8 / G1/4 / NPT1/2 / NPT1/8 / G1/8 / G1/2 |
| Filter, Filtration Level | 5µm | 0.3µm / 5µm | 5µm | 5µm | 5µm | 5µm |
| Compressed Air Quality | General Quality Dry Air | General Quality Dry Air | General Quality Dry Air / Clean Dry Air / Odorless Air | General Quality Dry Air | General Quality Dry Air | General Quality Dry Air |
| Max. Operating Pressure(MPa) | 1 ~ 1.0$1 | 1 | 0.97 | 1 ~ 1.0$1 | 1 | 1 |
| Relief Mechanism | Non-Relief / Relief | Non-Relief / Relief | Non-Relief | Non-Relief / Relief | Relief | Non-Relief / Relief |
| Flow Direction | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Standard Flow (Left to Right) | Standard Flow (Left to Right) / Reverse Flow (Right to Left) | Standard Flow (Left to Right) | Standard Flow (Left to Right) / Reverse Flow (Right to Left) |
| Condensate Drain | Manual / Auto/Manual / Not Provided | Manual / Automatic | Manual | Manual / Auto/Manual / Not Provided | Auto/Manual | Manual / Auto/Manual / Not Provided |
| Pressure Gauge | None (Pressure Port Plug not available) / With Standard Pressure Gauge | None (Pressure Port Plug available) / None (Pressure Port Plug not available) / With Standard Pressure Gauge / With Pressure Switch / With Pressure Sensor | None (Pressure Port Plug not available) / With Standard Pressure Gauge | None (Pressure Port Plug available) / With Standard Pressure Gauge / With Pressure Switch | With Standard Pressure Gauge | With Standard Pressure Gauge |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy