(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
| Days to Ship |
|
|---|

5-Port Solenoid Valve, Plug Lead Type, Compatible With Rechargeable Batteries 25A-SQ2000 Series
SMC
[Rechargeable battery compatible series]
Copper (Cu) and zinc (Zn) materials are not used to reduce product defects in the rechargeable battery manufacturing process.
Some aluminum alloys and die-cast aluminum materials contain small amounts of copper (Cu) and zinc (Zn) as additive elements.
Electrolytic nickel plating with copper base and zinc plating are not used. (Electroless nickel plating is used. )
It uses low dew point compatible grease, -70°C compatible, improved performance in low dew point environment.
| Days to Ship: | Quote |
|---|

5-Port Solenoid Valve, Body Ported, Plug Lead Unit, Rechargeable Battery Compatible, 25A-VQZ1000
SMC
[Rechargeable battery compatible series]
Copper (Cu) and zinc (Zn) materials are not used to reduce product defects in the rechargeable battery manufacturing process.
Some aluminum alloys and die-cast aluminum materials contain small amounts of copper (Cu) and zinc (Zn) as additive elements.
Electrolytic nickel plating with copper base and zinc plating are not used. (Electroless nickel plating is used. )
It uses low dew point compatible grease, -70°C compatible, improved performance in low dew point environment.
| Days to Ship: | Quote |
|---|

ATEX Directive 5-Port Solenoid Valve 52-SY Series ATEX Category 2
SMC
[What is ATEX Directive?]
Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.
■CE mark and ATEX
The ATEX Directive is now part of the CE mark, which incorporates the traditional European explosion-proof standard.
■Purpose of ATEX Directive
The main purposes of ATEX are:
・ Prevention of electrostatic charge
・ Ignition prevention of sparks caused by friction, impact, and abrasion
・ Ignition prevention due to temperature rise due to the same as above
・ The responsibility lies with the manufacturer
・ Certification by zone/category
■Zone/Category
In ATEX, the objects to be applied are classified into categories for each dangerous place (zone).
・ Zone 0: Category 1
Possibility of explosive atmosphere (Zone): Continuous or long time > 1,000 hours/year
・ Zone 1: Category 2
Possibility of explosive atmosphere (Zone): occasionally 10 to 1,000 hours/year
・ Zone 2: Category 3
Possibility of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
| Days to Ship: | Quote |
|---|

5 Port Solenoid Valve, Elastic Seal, Clean Series 10-SYJ7000 Series
SMC
[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom
| Standard Price: | MYR 551.02- |
|---|---|
| Days to Ship: | 27 Day(s) or more |

5-Port Solenoid Valve, Body Ported, Clean, 10-SY3000/5000/7000, Type 60
SMC
[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom
| Days to Ship: | Quote |
|---|

SMC
[Features]UL standard compatible, 3 port solenoid valve, Direct piping type.
| Days to Ship: | Quote |
|---|

5-Port Solenoid Valve, Plug-in Type, Clean Series, 10-SZ3000 Series
SMC
[10-Series, Clean Series]
Suitable for clean environment
Prevents dust generation in the cleanroom
| Days to Ship: | Quote |
|---|

5-Port Solenoid Valve Non-Plug-in Type Clean Series 10-SZ3000 Series
SMC
[10-Series, Clean Series]
Suitable for clean environment
Prevents dust generation in the cleanroom
| Days to Ship: | Quote |
|---|
5-Port Solenoid Valve, Plug-in SY5000/7000 Series Valve With Pressure Sensor
SMC
[Features]
・ Output pressure detection of 4 (A) and 2 (B) ports is possible
・ Detects abnormalities such as switching failure, response delay, back pressure interference, and pressure drop
・ Identification of abnormal parts such as actuators and solenoid valves
・ By mounting the pressure switch directly on the solenoid valve, space can be saved and installation man-hours can be reduced
| Days to Ship: | Quote |
|---|
| Days to Ship: | Quote |
|---|
| Brand |
|---|
| Product Series |
| CAD |
| Days to Ship |
| Number of Ports |
| Application |
| Switching Type |
| Voltage |
| Number of Solenoids |
| Mounting Orientation |
| Pipe Port Type |
| Specifications |
| Status at Power Off |
| Plumbing Thread Nominal |
| Plumbing |
| Applicable Cylinder Dia.(Ø) |
| Type |
| Driving Type |
| Connecting Tube Diameter |
| Pressure Rating(MPa) |
| Seal Type |
| CV Value |
| Pilot Air Supply |
| Brand | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC |
|---|---|---|---|---|---|---|---|---|---|---|
| Product Series | 5-Port Solenoid Valve, Plug Lead Type, Compatible With Rechargeable Batteries 25A-SQ2000 Series | 5-Port Solenoid Valve, Body Ported, Plug Lead Unit, Rechargeable Battery Compatible, 25A-VQZ1000 | ATEX Directive 5-Port Solenoid Valve 52-SY Series ATEX Category 2 | 5 Port Solenoid Valve, Elastic Seal, Clean Series 10-SYJ7000 Series | 5-Port Solenoid Valve, Body Ported, Clean, 10-SY3000/5000/7000, Type 60 | 5-Port Solenoid Valve, Plug-in Type, Clean Series, 10-SZ3000 Series | 5-Port Solenoid Valve Non-Plug-in Type Clean Series 10-SZ3000 Series | 5-Port Solenoid Valve, Plug-in SY5000/7000 Series Valve With Pressure Sensor | ||
| CAD |
| |||||||||
| Days to Ship | Quote | Quote | Quote | 27 Day(s) or more | Quote | Quote | Quote | Quote | Quote | Quote |
| Number of Ports | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 3-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve / Dual 3-Port Valve |
| Application | Unit for Manifold Mounting | Single Use | Single Use | Single Use | Unit for Manifold Mounting | Single Use | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting |
| Switching Type | 2-Position Exhaust | 2-Position Normally Closed / 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center | 2-Position Exhaust | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center | 2-Position Normally Open / 2-Position Normally Closed | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Exhaust / 3-Position Closed Center / Others | 2-Position Exhaust / 3-Position Closed Center | 2-Position Exhaust / 3-Position Exhaust Center / Others |
| Voltage | DC24V | DC24V / AC100V | DC12V | DC24V | DC24V / AC100V | DC24V | DC12V / DC24V | DC24V | DC24V | DC24V |
| Number of Solenoids | Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double |
| Mounting Orientation | Manifold Base | Direct | Direct | Direct | Manifold Base | Direct | Manifold Base | Manifold Base | Manifold Base | Manifold Base |
| Pipe Port Type | One-Touch Plumbing | One-Touch Plumbing | One-Touch Plumbing | One-Touch Plumbing | One-Touch Plumbing | One-Touch Plumbing | One-Touch Plumbing | One-Touch Plumbing | One-Touch Plumbing | One-Touch Plumbing |
| Specifications | Lubrication Free | Lubrication Free | Standard | Lubrication Free / Cleanroom | Lubrication Free / Cleanroom | Lubrication Free | Lubrication Free | Standard | Lubrication Free | Lubrication Free / Low Current |
| Status at Power Off | Self-Retaining | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) |
| Plumbing Thread Nominal | - | - | - | - | - | - | - | - | - | - |
| Plumbing | Direct Plumbing | Direct Plumbing | Direct Plumbing | Direct Plumbing | Direct Plumbing | Direct Plumbing | Direct Plumbing | Direct Plumbing | Direct Plumbing | Direct Plumbing |
| Applicable Cylinder Dia.(Ø) | 40 or less | 63 or less | - | - | - | - | - | - | 125 or less | - |
| Type | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves |
| Driving Type | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool |
| Connecting Tube Diameter | Ø6 | Ø6 | Ø6 | Ø6 | Ø6 | Ø6 | Ø6 | Ø6 | Ø6 | Ø6 |
| Pressure Rating(MPa) | 0.1 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 | 0.25 to 0.7 / 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | - | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.25 to 0.7 / 0.15 to 0.7 / 0.2 to 0.7 |
| Seal Type | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Standard | Standard | Standard / Soft Seal | Soft Seal |
| CV Value | 0.51 | 0.23 ~ 0.26 | 0.33 ~ 0.42 | 0.4 | - | - | 0.18 | 0.18 | - | 0.12 |
| Pilot Air Supply | Internal | Internal | Internal | Internal | Internal | Internal | Internal / External | Internal / External | Internal | Internal / External |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy