| Days to Ship |
|
|---|

5-Port Solenoid Valve, Plug-In Unit, Base Mounted, VQ1000 Series Valve
SMC
SMC Solenoid Valve.
[Features]
· Space-saving, reduced volume
· A screwless, one-clamp structure for easy valve replacement
· Built-in one-touch fitting makes piping work easy
· Slide-locking manual type available
| Days to Ship: | 3 Day(s) or more |
|---|

3-Port Solenoid Valve, Pilot Type, Rubber Seal SYJ700 Series
SMC
- 3-Port Solenoid Valve, Pilot Type, Rubber Seal SYJ700 Series from SMC.
- Innovative combination of space efficiency and performance superiority.
- Provides real value to the design solution.
- Small profile increases design flexibility and minimizes space requirements.
- Utilizes a low-power (0.5 watts standard) pilot solenoid design.
- Dramatically reduces thermal heat generation.
- Improves performance and decreases operating costs.
- Allows for direct control by PLC output relays.
- All electrical connections are available with lights and surge suppression.
| Days to Ship: | 3 Day(s) or more |
|---|

5-Port Solenoid Valve, Pilot Operated, VZS2000
SMC
SMC Solenoid Valve.
[Features]
· One-touch connection D-sub connector (MIL standard-compliant) for reduced wiring cost
· Excellent flow rate characteristics in a compact size (width: 15 mm)
· Easy to increase and decrease the number of manifold stations
· High operational frequency and a long product life (30,000,000 cycles or more), oil-free and can be used for dry-air operations
· Multiple wiring variations
· Low power consumption at just 1.8 W DC and supports serial transmission systems
| Days to Ship: | 21 Day(s) or more |
|---|

Vacuum Release Valve w/Restrictor SY3000, SY5000 (24 V DC)
SMC
An air pressure solenoid valve that allows vacuum suction with a single valve.
[Features]
· Control vacuum suction/release with one valve.
· Adjustable release air flow rate.
· Prevents workpieces from blowing away.
· Pilot specification: External pilot.
· Rated voltage: 24 V DC, 12 V DC.
| Days to Ship: | 21 Day(s) or more |
|---|

Vacuum Release Valve With Throttle Valve SJ3A6 Series
SMC
[Features]
・ 2 built-in spool valves.
· Control vacuum suction/release with one valve.
・ 10 mm width. (Same size as SJ3000 series)
・ With a throttle valve that can adjust the flow rate of break air.
・ Built-in replaceable filters on both vacuum side and break side.
・ It can be mixed with 4 port solenoid valve SJ2000/3000. (Made-to-order)
| Standard Price: | MYR 528.03- |
|---|---|
| Days to Ship: | 11 Day(s) or more |

Modular Connection Type, Residual Pressure Relief 3-Port Solenoid Valve VP500/700 Series
SMC
[Features]
・ Connect to F.R.L. combination
・ Space saving and reduction of piping labor-hours are possible
・ Power consumption: 0.35 W (Without light)
| Standard Price: | MYR 473.02- |
|---|---|
| Days to Ship: | 3 Day(s) or more |

5-Port Solenoid Valve, Starter Unit, Base Mounted, Rechargeable Battery Compatible, 25A-VQ4000
SMC
[Rechargeable battery compatible series]
Copper (Cu) and zinc (Zn) materials are not used in the rechargeable battery manufacturing process to reduce product defects.
Some aluminum alloys and die-cast aluminum materials contain small amounts of copper (Cu) and zinc (Zn) as additive elements.
Electrolytic nickel plating and zinc plating with copper base are not used. (Electroless nickel plating is used.)
It uses low dew point compatible grease, -70°C compatible, improved performance in low dew point environment.
| Standard Price: | MYR 576.68- |
|---|---|
| Days to Ship: | 27 Day(s) or more |

5-Port Solenoid Valve, Elastic Seal, Clean Series 10-SYJ5000 Series
SMC
[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom
| Days to Ship: | 14 Day(s) or more |
|---|

3-port solenoid valve, Pilot type elastic seal, clean series 10-SYJ300 series
SMC
[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom
| Days to Ship: | 3 Day(s) or more |
|---|

5-Port Solenoid Valve, Clean Series 10-SV1000/2000/3000/4000 Series
SMC
[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom
[Please click here for the catalog]
P.184 EX500 Distributed serial wiring support
P.265 Single unit / sub plate type [IP67 compliant]
| Standard Price: | MYR 452.32- |
|---|---|
| Days to Ship: | 27 Day(s) or more |

5-Port Solenoid Valve, Body Ported, Clean, 10-SY3000/5000/7000/9000
SMC
[10-Series, Clean Series]
· Suitable for clean environment
· It prevents dust generation in the cleanroom
| Standard Price: | MYR 398.07- |
|---|---|
| Days to Ship: | 3 Day(s) or more |
ATEX Directive 5-Port Solenoid Valve, 56-VQC1000 Series, ATEX Category 3
SMC
[What is ATEX Directive?]
Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.
■CE mark and ATEX
The ATEX Directive is now part of the CE mark, which incorporates the traditional European explosion-proof standard.
■Purpose of ATEX Directive
The main purposes of ATEX are:
・ Prevention of electrostatic charge
・ Ignition prevention of sparks caused by friction, impact, and abrasion
・ Ignition prevention due to temperature rise due to the same as above
・ The responsibility lies with the manufacturer
・ Certification by zone/category
■Zone/Category
In ATEX, the objects to be applied are classified into categories for each dangerous place (zone).
・ Zone 0: Category 1
Possibility of explosive atmosphere (Zone): Continuous or long time > 1,000 hours/year
・ Zone 1: Category 2
Possibility of explosive atmosphere (Zone): occasionally 10 to 1,000 hours/year
・ Zone 2: Category 3
Possibility of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
| Days to Ship: | 21 Day(s) or more |
|---|
ATEX Directive 5-Port Solenoid Valve, 56-VQC2000 Series, ATEX Category 3
SMC
[What is ATEX Directive?]
Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.
■CE mark and ATEX
The ATEX Directive is now part of the CE mark, which incorporates the traditional European explosion-proof standard.
■Purpose of ATEX Directive
The main purposes of ATEX are:
・ Prevention of electrostatic charge
・ Ignition prevention of sparks caused by friction, impact, and abrasion
・ Ignition prevention due to temperature rise due to the same as above
・ The responsibility lies with the manufacturer
・ Certification by zone/category
■Zone/Category
In ATEX, the objects to be applied are classified into categories for each dangerous place (zone).
・ Zone 0: Category 1
Possibility of explosive atmosphere (Zone): Continuous or long time > 1,000 hours/year
・ Zone 1: Category 2
Possibility of explosive atmosphere (Zone): occasionally 10 to 1,000 hours/year
・ Zone 2: Category 3
Possibility of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
| Days to Ship: | 21 Day(s) or more |
|---|
| Standard Price: | MYR 614.95 |
|---|---|
| Days to Ship: | 3 Day(s) |

Single Valve, Pilot-Operated 5-Port Valve, Selex Valve 4F0/1/2/3 Series
CKD
Possible to use hard and without lubrication. Excellent total performance, which can fit into a wide variety of fields with our selection. Note: CAD data of this series is being revised. Please wait till the corrections are done.
| Days to Ship: | 20 Day(s) or more |
|---|

Single Valve, Pilot-Operated 5-Port Valve, Selex Valve 4F4/5/6/7 Series
CKD
Possible to use hard and without lubrication. Excellent total performance, which can fit into a wide variety of fields with our selection. Note: CAD data of this series is being revised. Please wait till the corrections are done.
| Days to Ship: | 8 Day(s) or more |
|---|

DIN Terminal Box Type Pilot 5-Port Valve, ISO Compliant PV5G-6 Series
CKD
A valve conforming to the ISO standards which target international unification of valve mounting dimensions.
| Days to Ship: | 13 Day(s) or more |
|---|

Pilot-Operated 5-Port Valve Picozole 4SA/B0 Series
CKD
Ultra compact valve. This space-saving device contributes to weight reduction. Note: CAD data of this series is being revised. Please wait till the corrections are done.
| Days to Ship: | 9 Day(s) or more |
|---|

Individual Wiring Manifold M4KB1/2/3/4 Series Solenoid Valve Single Unit
CKD
Compact valve with a wide lineup. Note: CAD data of this series is being revised. Please wait till the corrections are done.
| Days to Ship: | 13 Day(s) or more |
|---|

4F2·4F3 series outdoor type option
CKD
Outdoor specs with improved waterproof functionality with a round terminal box. Note: CAD data of this series is being revised. Please wait till the corrections are done.
[Features]
· Suitable for outdoors use.
· Accelerated weather resistance (sunshine weather meter) test: 1, 000h clear.
· (Salt/wet/dry) combined cyclic corrosion test: 960h cleared.
· IP65 compatible (Applicable standards: IEC/EN 60529).
· A more robust seal structure is used for the lid of the terminal box.
· Uses a stainless steel screw.
| Days to Ship: | 12 Day(s) or more |
|---|

4-Way Solenoid Valve Pilot 4 Port Valve BN-760 Series
NIHON SEIKI
Robust type with large effective cross section.
| Standard Price: | MYR 1,763.66 |
|---|---|
| Days to Ship: | 8 Day(s) |

Base Pipe 3GB1: 2R Series, 4GB1: 2/3R Series, Single Valve
CKD
The new 3GB1/2R, 4GB1/2/3R series have inherited the legacy 3G/4G series concept and evolved it further.
[Environmental Performance]
· Continuous power OK (single solenoid type). Uses a new coil actuator.
· Reduced power consumption.
[Safety]
· Manual misoperation prevention (manual device has a protective cover).
· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).
· Foreign matter problem prevention
[Reliability]
· Low sliding · Realizes long life
· Improved leave response
[Ease of use]
· Wiring connector horizontal sharing
· Uses rotary connector
| Days to Ship: | 12 Day(s) or more |
|---|

Master valve 3GA1, 2, 3-R/4GA1, 2, 3-R series unit
CKD
The new 3GA1/2/3-R, 4GA1/2/3-R series have inherited the legacy 3G/4G series concept and evolved it further.
[Environmental Performance]
· Continuous power OK (single solenoid type). Uses a new coil actuator.
· Reduced power consumption.
[Safety]
· Manual misoperation prevention (manual device has a protective cover).
· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).
· Foreign matter problem prevention
[Reliability]
· Low sliding · Realizes long life
· Improved leave response
[Ease of use]
· Wiring connector horizontal sharing
· Uses rotary connector
| Days to Ship: | 12 Day(s) or more |
|---|

Individual Wiring Block Manifold, MN4GB1, 2R Series Valve Components
CKD
The new MN4GB1/2R series have inherited the legacy 3G/4G series concept and evolved it further.
[Environmental Performance]
· Continuous power OK (single solenoid type). Uses a new coil actuator.
· Reduced power consumption.
[Safety]
· Manual misoperation prevention (manual device has a protective cover).
· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).
· Foreign matter problem prevention
[Reliability]
· Low sliding · Realizes long life
· Improved leave response
[Ease of use]
· Wiring connector horizontal sharing
· Uses rotary connector
| Days to Ship: | 13 Day(s) or more |
|---|

Direct Piping3GD1/3GD2/3GD3R/4GD1/4GD2/4GD3R Series Unit Valve
CKD
The new 3GD1/2/3R, 4GD1/2/3R series have inherited the legacy 3G/4G series concept and evolved it further.
[Environmental Performance]
· Continuous power OK (single solenoid type). Uses a new coil actuator.
· Reduced power consumption.
[Safety]
· Manual misoperation prevention (manual device has a protective cover).
· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).
· Foreign matter problem prevention
[Reliability]
· Low sliding · Realizes long life
· Improved leave response
[Ease of use]
· Wiring connector horizontal sharing
· Uses rotary connector
| Days to Ship: | 12 Day(s) or more |
|---|

Base Pipe 3GE1・2R/4GE1・2・3R Series Unit Valve
CKD
The new 3GE1/2R, 4GE1/2/3R series have inherited the legacy 3G/4G series concept and evolved it further.
[Environmental Performance]
· Continuous power OK (single solenoid type). Uses a new coil actuator.
· Reduced power consumption.
[Safety]
· Manual misoperation prevention (manual device has a protective cover).
· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).
· Foreign matter problem prevention
[Reliability]
· Low sliding · Realizes long life
· Improved leave response
[Ease of use]
· Wiring connector horizontal sharing
· Uses rotary connector
| Days to Ship: | 12 Day(s) or more |
|---|

Individual Wiring Manifold, M3, 4GD1, 2, 3R-(D) Series, Unit
CKD
The new M3/4GD1/2/3R-(D) series have inherited the legacy 3G/4G series concept and evolved it further.
[Environmental Performance]
· Continuous power OK (single solenoid type). Uses a new coil actuator.
· Reduced power consumption.
[Safety]
· Manual misoperation prevention (manual device has a protective cover).
· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).
· Foreign matter problem prevention
[Reliability]
· Low sliding · Realizes long life
· Improved leave response
[Ease of use]
· Wiring connector horizontal sharing
· Uses rotary connector
| Days to Ship: | 12 Day(s) or more |
|---|

Individual Wiring Manifold, M3GE1, 2/M4GE1-3R-(D) Series, Unit
CKD
The new M3GE1/2/M4GE1 to 3R-(D) series have inherited the legacy 3G/4G series concept and evolved it further.
[Environmental Performance]
· Continuous power OK (single solenoid type). Uses a new coil actuator.
· Reduced power consumption.
[Safety]
· Manual misoperation prevention (manual device has a protective cover).
· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).
· Foreign matter problem prevention
[Reliability]
· Low sliding · Realizes long life
· Improved leave response
[Ease of use]
· Wiring connector horizontal sharing
· Uses rotary connector
| Days to Ship: | 12 Day(s) or more |
|---|

Wire-Saving Manifold, M3/4GE1–3R-T*(D) Series, Unit
CKD
The new M3/4GE1 to 3R-T*(D) series have inherited the legacy 3G/4G series concept and evolved it further.
[Environmental Performance]
· Continuous power OK (single solenoid type). Uses a new coil actuator.
· Reduced power consumption.
[Safety]
· Manual misoperation prevention (manual device has a protective cover).
· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).
· Foreign matter problem prevention
[Reliability]
· Low sliding · Realizes long life
· Improved leave response
[Ease of use]
· Wiring connector horizontal sharing
· Uses rotary connector
| Days to Ship: | 13 Day(s) or more |
|---|

Individual Wiring Block Manifold, MN4GE1, 2R Series Valve Components
CKD
The new MN4GD1/2R series have inherited the legacy 3G/4G series concept and evolved it further.
[Environmental Performance]
· Continuous power OK (single solenoid type). Uses a new coil actuator.
· Reduced power consumption.
[Safety]
· Manual misoperation prevention (manual device has a protective cover).
· Suppresses malfunctioning problems (metal base, exhaust malfunction prevention valve regardless of resin block come as standard).
· Foreign matter problem prevention
[Reliability]
· Low sliding · Realizes long life
· Improved leave response
[Ease of use]
· Wiring connector horizontal sharing
· Uses rotary connector
| Days to Ship: | 13 Day(s) or more |
|---|

5-Port Solenoid Valve, Plug-In Unit, Sub-Plate Single Unit VQ2000 Series
SMC
An easy-to-use, terminal block type sub-plate single unit.
[Features]
· Protective enclosure conforms to IP65 standard.
· Compatible with VQ2000 only.
· -Q: CE compliant (CE-compliant products are DC specification only.)
· Thread type: Rc. NPT, NPTF, G.
· Port diameter: 1/4.
· Protective structure: Dust-proof (No mark) · IP65 (Dust-proof, blow-proof) (-W).
*Valves specified as "-W" have IP65 protection.
*Standard valve (dust-proof) specifications do not support 200 V, 220 V AC.
| Standard Price: | MYR 634.41- |
|---|---|
| Days to Ship: | 3 Day(s) or more |

5-Port Solenoid Valve, Plug-In Cassette Type, SQ1000 Series Valve
SMC
SMC Solenoid Valve.
[Features]
· Clip type one-touch fittings for easy replacement of fittings
· The connector entry direction can be changed with a single push
· 4 position, dual 3-port valve
· Built-in back pressure check valve
| Days to Ship: | 3 Day(s) or more |
|---|

5-Port Solenoid Valve, Plug-In Cassette Type, SQ2000 Series Valve
SMC
SMC Solenoid Valve.
[Features]
· Clip type one-touch fittings for easy replacement of fittings
· The connector entry direction can be changed with a single push
· 4 position, dual 3-port valve
· Built-in back pressure check valve
| Days to Ship: | 3 Day(s) or more |
|---|

5-Port Solenoid Valve, Plug Lead Type, SQ1000 Series, Valve
SMC
SMC Solenoid Valve.
[Features]
· Clip type one-touch fittings for easy replacement of fittings
· The connector entry direction can be changed with a single push
· 4 position, dual 3-port valve
· Built-in back pressure check valve
| Days to Ship: | 3 Day(s) or more |
|---|

5-Port Solenoid Valve, Pilot Operated, Elastic Material Seal, VFR3000
SMC
A solenoid valve whose main valve structure is an elastic body seal.
[Features]
・ VFR3000 Series
・ Abundant size variations
・ For driving medium and large cylinders
・ Manifold model: VV5FR2, VV5FR3, VV5FR4, VV5FR5
| Days to Ship: | 3 Day(s) or more |
|---|

3-Port 3-Position Valve VEX3 Series (Air Operated / Pilot Solenoid)
SMC
An SMC 3-position valve with 3 manual operating methods added.
[Features]
· Intermediate stopping of cylinders with a maximum ø125 (diameter 125 mm) is possible.
· Power consumption: 1 W.
· Body ported type.
· Body type: Air-operated type S / pilot solenoid type.
· Thread type: Rc, G, NPT.
· Operating method: External pilot solenoid type / Internal pilot solenoid type.
| Standard Price: | MYR 662.24- |
|---|---|
| Days to Ship: | 17 Day(s) or more |

5-Port Solenoid Valve, Plug Lead Type S0700 Series
SMC
4-position, dual 3-port valve solenoid valve.
[Features]
· Features direct manual override.
· RoHS-compliant.·
· Voltage: 24 V DC, 12 V DC.
· Function: Standard type, external pilot (*dual 3-port cannot be supported.)
| Days to Ship: | 3 Day(s) or more |
|---|

5-Port Solenoid Valve, Body Ported, Single Unit (SX3000/SX5000/SX700 Series)
SMC
Pilot valves are concentrated on one side, enabling wiring to be bundled and giving the solenoid valve a streamlined appearance.
[Features]
· Low power consumption of 0.6 W. High reliability and long service life of 50 million cycles or more.
· Indicator light and manual override have been consolidated. Compact design with large flow.
· Quick response of 10 ms.
· Improved drainage resistance. Suitable for use in copper-free and fluorine-free applications.
· Attractive design with bright color tones.
· No exhaust mist or exhaust noise from pilot valve.
· Same manifold base as SY Series.
· The cylinder port sizes can be changed.
| Days to Ship: | Quote |
|---|

5-Port Solenoid Valve, Base Mounted, Single Unit SX3000/5000/7000 Series
SMC
SMC Solenoid Valve.
[Features]
· The pilot valve is concentrated on one side with its wiring gathered as one, giving it a neat and tidy appearance
· Low power consumption at just 0.6 W
· High reliability and long service life of 50 million cycles or more
· Compact and with a large flow capacity
· High speed response of 10 ms
· Improved drain resistance adaptability
· Suitable for use in copper and fluorine-free applications
· Attractive design with bright color tones
· Consolidation of indicator lights and manual
· Removal of pilot valve exhaust mist and sound
· Uses a common base with the SY Series
· The cylinder port size can be changed
| Standard Price: | MYR 525.47- |
|---|---|
| Days to Ship: | 3 Day(s) or more |

4-Port Solenoid Valve, Body Ported, VZ1000 Series
SMC
SMC Solenoid Valve.
[Features]
· Suitable for cylinder actuation (up to ø16)
· Compact size with a width of just 15 mm
· Low power consumption: 1.8 W DC
| Days to Ship: | 3 Day(s) or more |
|---|

5-Port Solenoid Valve, Pilot Operated, VZS3000
SMC
SMC Solenoid Valve.
[Features]
· One-touch connection D-sub connector (MIL standard-compliant) for reduced wiring cost
· Excellent flow rate characteristics in a compact size (width: 18 mm)
· Easy to increase and decrease the number of manifold stations
· High operational frequency and a long product life (30,000,000 cycles or more), oil-free and can be used for dry-air operations
· Multiple wiring variations
· Low power consumption at just 1.8 W DC and supports serial transmission systems
| Days to Ship: | 21 Day(s) or more |
|---|

NAMUR Standard Compliant 5-Port Solenoid Valve VFN2000N Series
SMC
[Features]
· Interface surface is compliant with NAMUR standard.
· Can be installed directly on NAMUR standard-compliant industrial valve actuators.
| Standard Price: | MYR 571.27- |
|---|---|
| Days to Ship: | 3 Day(s) or more |

5 Port Solenoid Valve, Plug-in Unit Clean Series 10-SQ1000 Series
SMC
[10-Series Clean Series]
・ This product can be used in a clean environment.
・ Prevents dust generation in the cleanroom.
| Days to Ship: | 17 Day(s) or more |
|---|

5-Port Solenoid Valve, Plug-in Type, Clean Series 10-SQ2000 Series
SMC
[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom
| Standard Price: | MYR 450.71- |
|---|---|
| Days to Ship: | 27 Day(s) or more |

5 Port Solenoid Valve, Plug Lead Type SQ2000 Series
SMC
[Features]
・ Power saving, power consumption: 0.4 W 。 (Standard)
・ Easy to increase and decrease valves.
・ Maintenance labor hours are reduced by installing one screw.
・ Quick-connect fitting replacement is easy with the clip type.
・ The connector entry direction can be changed with one push.
・ 4-position dual 3-port valve.
・ Built-in back pressure check valve. (Option)
| Days to Ship: | 14 Day(s) or more |
|---|
| Brand |
|---|
| Product Series |
| CAD |
| Days to Ship |
| Number of Ports |
| Application |
| Switching Type |
| Voltage |
| Number of Solenoids |
| Mounting Orientation |
| Pipe Port Type |
| Specifications |
| Status at Power Off |
| Plumbing Thread Nominal |
| Plumbing |
| Applicable Cylinder Dia.(Ø) |
| Type |
| Driving Type |
| Connecting Tube Diameter |
| Pressure Rating(MPa) |
| Seal Type |
| CV Value |
| Pilot Air Supply |
| |||||||||||||||||||||||||||||||||||||||||||||
| Brand | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | CKD | CKD | CKD | CKD | CKD | CKD | NIHON SEIKI | CKD | CKD | CKD | CKD | CKD | CKD | CKD | CKD | CKD | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC |
| Product Series | 5-Port Solenoid Valve, Plug-In Unit, Base Mounted, VQ1000 Series Valve | 3-Port Solenoid Valve, Pilot Type, Rubber Seal SYJ700 Series | Modular Connection Type, Residual Pressure Relief 3-Port Solenoid Valve VP500/700 Series | 5-Port Solenoid Valve, Starter Unit, Base Mounted, Rechargeable Battery Compatible, 25A-VQ4000 | 5-Port Solenoid Valve, Elastic Seal, Clean Series 10-SYJ5000 Series | 3-port solenoid valve, Pilot type elastic seal, clean series 10-SYJ300 series | 5-Port Solenoid Valve, Clean Series 10-SV1000/2000/3000/4000 Series | 5-Port Solenoid Valve, Body Ported, Clean, 10-SY3000/5000/7000/9000 | ATEX Directive 5-Port Solenoid Valve, 56-VQC1000 Series, ATEX Category 3 | ATEX Directive 5-Port Solenoid Valve, 56-VQC2000 Series, ATEX Category 3 | 3-Port Solenoid, Residual Pressure Relief, Modular Connection, VP500 / 700 Series | Single Valve, Pilot-Operated 5-Port Valve, Selex Valve 4F0/1/2/3 Series | Single Valve, Pilot-Operated 5-Port Valve, Selex Valve 4F4/5/6/7 Series | DIN Terminal Box Type Pilot 5-Port Valve, ISO Compliant PV5G-6 Series | Individual Wiring Manifold M4KB1/2/3/4 Series Solenoid Valve Single Unit | Individual Wiring Block Manifold, MN4GB1, 2R Series Valve Components | Direct Piping3GD1/3GD2/3GD3R/4GD1/4GD2/4GD3R Series Unit Valve | Individual Wiring Manifold, M3, 4GD1, 2, 3R-(D) Series, Unit | Individual Wiring Manifold, M3GE1, 2/M4GE1-3R-(D) Series, Unit | Individual Wiring Block Manifold, MN4GE1, 2R Series Valve Components | 5-Port Solenoid Valve, Plug-In Unit, Sub-Plate Single Unit VQ2000 Series | 5-Port Solenoid Valve, Plug-In Cassette Type, SQ1000 Series Valve | 5-Port Solenoid Valve, Plug-In Cassette Type, SQ2000 Series Valve | 5-Port Solenoid Valve, Pilot Operated, Elastic Material Seal, VFR3000 | 3-Port 3-Position Valve VEX3 Series (Air Operated / Pilot Solenoid) | 5-Port Solenoid Valve, Body Ported, Single Unit (SX3000/SX5000/SX700 Series) | 5-Port Solenoid Valve, Base Mounted, Single Unit SX3000/5000/7000 Series | NAMUR Standard Compliant 5-Port Solenoid Valve VFN2000N Series | 5 Port Solenoid Valve, Plug-in Unit Clean Series 10-SQ1000 Series | 5-Port Solenoid Valve, Plug-in Type, Clean Series 10-SQ2000 Series | |||||||||||||||
| CAD |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||||
| Days to Ship | 3 Day(s) or more | 3 Day(s) or more | 21 Day(s) or more | 21 Day(s) or more | 11 Day(s) or more | 3 Day(s) or more | 27 Day(s) or more | 14 Day(s) or more | 3 Day(s) or more | 27 Day(s) or more | 3 Day(s) or more | 21 Day(s) or more | 21 Day(s) or more | 3 Day(s) | 20 Day(s) or more | 8 Day(s) or more | 13 Day(s) or more | 9 Day(s) or more | 13 Day(s) or more | 12 Day(s) or more | 8 Day(s) | 12 Day(s) or more | 12 Day(s) or more | 13 Day(s) or more | 12 Day(s) or more | 12 Day(s) or more | 12 Day(s) or more | 12 Day(s) or more | 13 Day(s) or more | 13 Day(s) or more | 3 Day(s) or more | 3 Day(s) or more | 3 Day(s) or more | 3 Day(s) or more | 3 Day(s) or more | 17 Day(s) or more | 3 Day(s) or more | Quote | 3 Day(s) or more | 3 Day(s) or more | 21 Day(s) or more | 3 Day(s) or more | 17 Day(s) or more | 27 Day(s) or more | 14 Day(s) or more |
| Number of Ports | 5-Port Valve / Dual 3-Port Valve | 3-Port Valve | 5-Port Valve | 3-Port Valve | 3-Port Valve | 3-Port Valve | 5-Port Valve | 5-Port Valve | 3-Port Valve | 5-Port Valve / Dual 3-Port Valve | 5-Port Valve | 5-Port Valve / Dual 3-Port Valve | 5-Port Valve / Dual 3-Port Valve | 3-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 4-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve / Dual 3-Port Valve | 5-Port Valve / Dual 3-Port Valve | 5-Port Valve / Dual 3-Port Valve | 5-Port Valve / Dual 3-Port Valve | 5-Port Valve | 3-Port Valve | 5-Port Valve / Dual 3-Port Valve | 5-Port Valve | 5-Port Valve | 4-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve / Dual 3-Port Valve |
| Application | Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Single Use | Single Use / Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Single Use | Unit for Manifold Mounting | Unit for Manifold Mounting | Single Use | Single Use | Single Use | Single Use | Single Use | Unit for Manifold Mounting | Single Use | Single Use | Single Use | Single Use | Unit for Manifold Mounting | Single Use | Single Use | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Single Use | Single Use / Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Single Use | Single Use / Manifolds / Unit for Manifold Mounting | Single Use | Unit for Manifold Mounting | Single Use | Single Use / Unit for Manifold Mounting | Single Use | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting |
| Switching Type | 2-Position Normally Open / 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Normally Open / 2-Position Normally Closed | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | Others | Others | 2-Position Normally Closed | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center | 2-Position Normally Open / 2-Position Normally Closed | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Normally Closed | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center | 2-Position Exhaust | 2-Position Exhaust / 3-Position Closed Center | 2-Position Exhaust | 2-Position Exhaust | 2-Position Pressure | 2-Position Exhaust / 3-Position Closed Center / 3-Position Pressure Center | 3-Position Closed Center | 2-Position Exhaust | 2-Position Exhaust | 2-Position Exhaust | 2-Position Exhaust / 3-Position Closed Center | 2-Position Exhaust / 3-Position Closed Center | 2-Position Exhaust | 2-Position Exhaust | 2-Position Normally Open / 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center | 2-Position Normally Closed / 3-Position Closed Center | 2-Position Exhaust / 2-Position Pressure / 3-Position Closed Center / Others | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center | 2-Position Exhaust | 2-Position Exhaust | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others | 2-Position Exhaust | 2-Position Exhaust / 3-Position Closed Center | 2-Position Exhaust / 3-Position Closed Center / 3-Position Pressure Center | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center / Others |
| Voltage | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V / DC5V / DC6V / DC3V | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V | DC12V / DC24V | DC12V / DC24V | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V | DC24V / AC100V / AC110V / AC200V / AC220V | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V / DC5V | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V / DC5V | DC24V | DC24V / AC100V / AC200V / AC220V / DC5V | DC24V | DC24V | DC24V | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V | DC12V / DC24V / AC100V / AC110V | DC12V / DC24V / DC5V / DC6V | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V | AC200V | DC12V / DC24V / AC100V / AC200V / DC5V / DC3V | - | - | - | - | - | - | - | - | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V | DC12V / DC24V | DC12V / DC24V | DC12V / DC24V | DC12V / DC24V / AC100V / AC200V / AC220V / 110/120 V AC / AC240V | DC12V / DC24V / AC100V / AC200V / AC220V | DC12V / DC24V | DC12V / DC24V | DC24V | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V | DC12V / DC24V / AC100V / AC110V / AC200V / AC220V | DC12V / DC24V / AC100V / AC200V / AC220V / 110/120 V AC / AC240V | DC24V | DC24V | DC12V / DC24V |
| Number of Solenoids | Single / Double | Single | Single / Double | Single | Double | Single | Single / Double | Single / Double | Single | Single / Double | Single / Double | Single / Double | Single / Double | Single | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Double | Single | Single / Double | Double | Single | Single / Double | Single | Single / Double | Single / Double | Single / Double | Single | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double | Double | Single / Double | Single / Double | Single / Double | Single | Single / Double | Single / Double | Single / Double | Single / Double | Single / Double |
| Mounting Orientation | Manifold Base | Direct / Manifold Base | Direct / Manifold Base | Manifold Base | Manifold Base | Direct | Direct / Manifold Base | Direct / Manifold Base | Direct / Manifold Base | Direct / Manifold Base | Direct | Manifold Base | Manifold Base | Direct | Direct | Manifold Base | Manifold Base | Direct / Manifold Base | Manifold Base | Direct | Direct | Manifold Base | Direct | Manifold Base | Direct | Manifold Base | Manifold Base | Manifold Base | Manifold Base | Manifold Base | Direct | Direct / Manifold Base | Direct / Manifold Base | Direct / Manifold Base | Direct / Manifold Base | Direct | Direct / Manifold Base | Direct | Manifold Base | Direct | Direct / Manifold Base | Direct | Manifold Base | Manifold Base | Manifold Base |
| Pipe Port Type | - | Rc (R) / NPT / NPTF / G | Rc (R) / NPT / NPTF / G | One-Touch Plumbing | M | G | Rc (R) / NPT | M / Rc (R) / NPT / NPTF / One-Touch Plumbing | M | Rc (R) / NPT / NPTF / G | M / Rc (R) / G / One-Touch Plumbing | - | - | G | M / Rp | Rc (R) | Rc (R) | M / Barbed Couplers | - | Rp | Rc (R) | Rc (R) / NPT / G | Rc (R) / One-Touch Plumbing | - | - | - | One-Touch Plumbing | Others | Others | - | Rc (R) / NPT / NPTF / G | M / One-Touch Plumbing | One-Touch Plumbing | M / One-Touch Plumbing | Rc (R) / NPT / NPTF / G | Rc (R) / NPT / G | M / One-Touch Plumbing | M / Rc (R) / NPT / G / One-Touch Plumbing | - | M | Rc (R) / NPT / G | Rc (R) / NPT / G | One-Touch Plumbing | One-Touch Plumbing | One-Touch Plumbing |
| Specifications | Standard | Standard / Lubrication Free | Standard / High Frequency / Lubrication Free / Low Current | Standard | Lubrication Free | Lubrication Free | Drip-Proof / Lubrication Free | Lubrication Free / Cleanroom | Lubrication Free / Cleanroom | Lubrication Free / Cleanroom | Lubrication Free / Cleanroom | Drip-Proof / Lubrication Free | Drip-Proof / Lubrication Free | Lubrication Free | Standard / Lubrication Free / No Copper, fluoropolymer Type Material | Standard / Lubrication Free / No Copper, fluoropolymer Type Material | Standard / Drip-Proof / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free / No Copper, fluoropolymer Type Material | Standard / Lubrication Free | Standard | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Drip-Proof / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free | Standard / Lubrication Free / Low Current | Standard / Lubrication Free / No Copper, fluoropolymer Type Material / Low Current | Standard / Lubrication Free / No Copper, fluoropolymer Type Material / Low Current | Standard / Low Current | Standard / High Frequency / Lubrication Free / Low Current | Standard | Lubrication Free / Low Current | Lubrication Free | Lubrication Free |
| Status at Power Off | Self-Retaining / Self-Recovery (Spring Return) | Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Recovery (Pressure Differential Return) | Self-Recovery (Pressure Differential Return) | Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining | Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Recovery (Spring Return) | Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Pressure Differential Return) | Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Pressure Differential Return) | Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Pressure Differential Return) | Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining / Self-Recovery (Spring Return) |
| Plumbing Thread Nominal | - | 1/4 ~ 1/8 | 1/8 | - | M5 | 1/2 ~ 3/8 | 1/4 ~ 3/8 | 1/8 ~ M5 | M3 ~ M5 | 1/2 ~ 3/8 | 1/4 ~ M5 | - | - | 3/8 | 1/4 ~ M5 | 1 ~ 3/8 | 1/4 ~ 3/8 | M3 ~ M5 | - | 1/4 | 1/4 | 1/4 ~ 3/8 | 1/4 | - | - | - | - | - | - | - | 1/4 | M5 | - | M5 | 1/4 ~ 3/8 | 1/2 ~ 3/8 | M5 | 1/4 ~ M5 | - | M5 | 1/4 ~ 1/8 | 1/4 | - | - | - |
| Plumbing | Sub-Base Plumbing | Direct Plumbing / Sub-Base Plumbing | Sub-Base Plumbing | Direct Plumbing / Sub-Base Plumbing | Direct Plumbing | Direct Plumbing | Sub-Base Plumbing | Direct Plumbing / Sub-Base Plumbing | Direct Plumbing / Sub-Base Plumbing | Sub-Base Plumbing | Direct Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Direct Plumbing | Direct Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Direct Plumbing / Sub-Base Plumbing | Sub-Base Plumbing | Direct Plumbing | Direct Plumbing | Sub-Base Plumbing | Direct Plumbing | Sub-Base Plumbing | Direct Plumbing | Sub-Base Plumbing | Direct Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Direct Plumbing | Direct Plumbing | Direct Plumbing | Sub-Base Plumbing | Direct Plumbing | Direct Plumbing / Sub-Base Plumbing | Direct Plumbing | Sub-Base Plumbing | Direct Plumbing | Sub-Base Plumbing | Direct Plumbing | Direct Plumbing | Direct Plumbing | Direct Plumbing |
| Applicable Cylinder Dia.(Ø) | 80 or Less | - | 63 or less | 80 or Less ~ 125 or less | - | - | 200 or less | - | - | - | 63 or less ~ 160 or Less | 80 or Less | 100 or Less | - | 16 to 20 ~ 63 to 100 | 63 to 100 ~ 180 to 250 | 100 or Less | 6 to 25 | 20 to 40 | - | - | 20 to 40 ~ 63 to 100 | 63 to 100 | 40 to 80 | 20 to 40 ~ 63 to 100 | 20 to 40 | 20 to 40 ~ 63 to 100 | 20 to 40 ~ 63 to 100 | 40 to 80 | 20 to 40 | 100 or Less | 40 or less | 40 or less | 40 or less | 40 to 140 ~ 40 to 200 | 20 to 100 ~ 50 to 200 | 6 to 25 ~ 50 or Less | 63 or less ~ 100 or Less | - | 16 or less | 80 or Less | - | 40 or less | 40 or less | 40 or less |
| Type | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Master Valve | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves |
| Driving Type | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool |
| Connecting Tube Diameter | - | - | - | Ø4 / Ø6 / Ø8 | - | - | - | Ø4 / Ø6 | - | - | Ø4 / Ø6 / Ø8 / Ø10 / Ø12 | - | - | - | - | - | - | Ø4 | - | - | - | - | Ø6 / Ø8 / Ø10 | - | - | - | - | - | - | - | - | Ø3.2 / Ø4 / Ø6 / Ø1/8 / Ø5/32 / Ø1/4 | Ø4 / Ø6 / Ø8 | Ø3.2 / Ø4 / Ø6 / Ø5/32 / Ø1/4 | - | - | Ø4 / Ø1/8 / Ø5/32 / ø2 | Ø4 / Ø6 / Ø8 / Ø10 | - | - | - | - | Ø4 / Ø6 | Ø4 / Ø6 / Ø8 | Ø4 / Ø6 / Ø8 / Ø1/4 |
| Pressure Rating(MPa) | 1.0 | 0.15 to 0.7 / -0.1 to 0.7 | 0.1 to 1.0 | -0.1 to 0.7 | -0.1 to 0.7 | 0.2 to 0.7 / 0.2 to 1 | 0.15 to 1 / 0.2 to 1 | 0.15 to 0.7 / 0.1 to 0.7 | 0.15 to 0.7 | 0.25 to 0.7 / 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.2 to 0.7 | - | - | - | - | - | - | 0.15 to 0.8 | - | - | - | - | - | - | - | - | - | 1.0 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 / 0.1 to 1.0 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 / 0.1 to 1.0 | 02 to 0.9 / 0.1 ~ 0.9 | 0.2 to 0.7 / -0.1 to 1 | 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 | 0.15 to 0.7 | 0.1 to 1.0 | 0.15 to 0.9 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 |
| Seal Type | Standard / Soft Seal | Soft Seal | Standard | Soft Seal | Soft Seal | Standard | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Standard / Soft Seal | Standard / Soft Seal | Standard | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Standard | Standard | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Standard / Soft Seal | Standard / Soft Seal | Standard / Soft Seal | Standard / Soft Seal | Soft Seal | Standard | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Standard | Soft Seal | Soft Seal | Soft Seal | Standard / Soft Seal |
| CV Value | - | 0.68 ~ 0.77 | 0.21 ~ 0.28 | - | 0.05 | 2 ~ 2.9 | 1.9 ~ 2.1 | - | 0.086 ~ 0.089 | 0.24 ~ 2.2 | 0.13 ~ 1.9 | 0.16 ~ 0.21 | 0.46 ~ 0.8 | 2 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 0.46 ~ 0.8 | 0.14 ~ 0.19 | 0.4 ~ 0.56 | 0.14 ~ 0.19 | 0.69 ~ 2.2 | - | 0.07 ~ 0.18 | 0.11 ~ 0.93 | - | 0.05 | 0.56 ~ 0.6 | 0.85 | 0.15 ~ 0.19 | 0.46 ~ 0.56 | 0.4 ~ 0.56 |
| Pilot Air Supply | Internal / External | Internal / External | Internal / External | External | External | Internal | Internal / External | Internal | Internal | Internal / External | Internal | Internal / External | Internal / External | Internal | Internal | - | - | - | - | Internal | Internal | - | - | - | - | - | - | - | - | - | Internal / External | Internal / External | Internal / External | Internal / External | Internal / External | Internal / External | Internal / External | Internal | Internal | Internal | Internal / External | Internal | Internal | Internal | Internal / External |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy