(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
| Days to Ship |
|
|---|

ATEX Directive 5-Port Solenoid Valve 52-SY Series ATEX Category 2
SMC
[What is ATEX Directive?]
Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.
■CE mark and ATEX
The ATEX Directive is now part of the CE mark, which incorporates the traditional European explosion-proof standard.
■Purpose of ATEX Directive
The main purposes of ATEX are:
・ Prevention of electrostatic charge
・ Ignition prevention of sparks caused by friction, impact, and abrasion
・ Ignition prevention due to temperature rise due to the same as above
・ The responsibility lies with the manufacturer
・ Certification by zone/category
■Zone/Category
In ATEX, the objects to be applied are classified into categories for each dangerous place (zone).
・ Zone 0: Category 1
Possibility of explosive atmosphere (Zone): Continuous or long time > 1,000 hours/year
・ Zone 1: Category 2
Possibility of explosive atmosphere (Zone): occasionally 10 to 1,000 hours/year
・ Zone 2: Category 3
Possibility of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
| Days to Ship: | 3 Day(s) or more |
|---|

3-port solenoid valve, pilot type, elastic seal, clean series 10-SYJ500 series
SMC
[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom
| Days to Ship: | 21 Day(s) or more |
|---|

3-port solenoid valve, pilot type, elastic seal, clean series 10-SYJ700 series
SMC
[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom
| Days to Ship: | Quote |
|---|

5-Port Solenoid Valve, Base Mounted, Clean, 10-SY3000/5000/7000/9000
SMC
[10-Series, Clean Series]
· Suitable for clean environment
· It prevents dust generation in the cleanroom
| Standard Price: | MYR 407.01- |
|---|---|
| Days to Ship: | 27 Day(s) or more |

3-Port Solenoid Valve, Direct-Acting, Elastic Body Seal, Clean Series 10-SY100 Series
SMC
[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom
| Days to Ship: | 11 Day(s) or more |
|---|

3-Port Solenoid Valve, Direct Acting Type, Elastic Material Seal, Clean, Large Flow Rate Type
SMC
[10-Series, Clean Series]
・ Suitable for clean environment
· It prevents dust generation in the cleanroom
| Days to Ship: | Quote |
|---|

SMC
Can only be used in Japan as an intrinsically safe explosion-proof structure certified product
・ Exia II BT4 (TIIS certified product)
This product has been certified as an intrinsically safe explosion-proof system that combines an electromagnet for solenoid valves and a safety cage in the explosion-proof structure electromechanical equipment type certification of the Industrial Safety Technology Association of Japan (TIIS).
* Due to the system display and the selection of the attached barrier, the B (Zener type) barrier has been discontinued (December, 2017). Select A (Zener type) or F (Insulated type).
| Days to Ship: | 21 Day(s) or more |
|---|

5-Port Solenoid Valve, Base Mounted Type, Clean, 10-S0700
SMC
[10-Series, Clean Series]
Suitable for clean environment
Prevents dust generation in the cleanroom
| Days to Ship: | Quote |
|---|

5-Port Solenoid Valve, Plug-in Type, Clean Series, 10-SZ3000 Series
SMC
[10-Series, Clean Series]
Suitable for clean environment
Prevents dust generation in the cleanroom
| Days to Ship: | Quote |
|---|

Guide integrated cylinder with valve Valve for MVGQ series (For ø25 to ø63)
SMC
Guide integrated cylinder with valve MVGQ series, valve for ø25 to ø63.
| Days to Ship: | Quote |
|---|

Guide integrated cylinder with valve Valve for MVGQ series (For ø12 to ø20)
SMC
Guide integrated cylinder with valve MVGQ series, valve for ø12 to ø20.
| Days to Ship: | Quote |
|---|
| Brand |
|---|
| Product Series |
| CAD |
| Days to Ship |
| Number of Ports |
| Application |
| Switching Type |
| Voltage |
| Number of Solenoids |
| Mounting Orientation |
| Pipe Port Type |
| Specifications |
| Status at Power Off |
| Plumbing Thread Nominal |
| Plumbing |
| Applicable Cylinder Dia.(Ø) |
| Type |
| Driving Type |
| Connecting Tube Diameter |
| Pressure Rating(MPa) |
| Seal Type |
| CV Value |
| Pilot Air Supply |
| Brand | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Product Series | ATEX Directive 5-Port Solenoid Valve 52-SY Series ATEX Category 2 | 3-port solenoid valve, pilot type, elastic seal, clean series 10-SYJ500 series | 3-port solenoid valve, pilot type, elastic seal, clean series 10-SYJ700 series | 5-Port Solenoid Valve, Base Mounted, Clean, 10-SY3000/5000/7000/9000 | 3-Port Solenoid Valve, Direct-Acting, Elastic Body Seal, Clean Series 10-SY100 Series | 3-Port Solenoid Valve, Direct Acting Type, Elastic Material Seal, Clean, Large Flow Rate Type | 5-Port Solenoid Valve, Plug-in Type, Clean Series, 10-SZ3000 Series | Guide integrated cylinder with valve Valve for MVGQ series (For ø25 to ø63) | Guide integrated cylinder with valve Valve for MVGQ series (For ø12 to ø20) | ||
| CAD | |||||||||||
| Days to Ship | 3 Day(s) or more | 21 Day(s) or more | Quote | 27 Day(s) or more | 11 Day(s) or more | Quote | 21 Day(s) or more | Quote | Quote | Quote | Quote |
| Number of Ports | 5-Port Valve | 3-Port Valve | 3-Port Valve | 5-Port Valve | 3-Port Valve | 3-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 5-Port Valve | 4-Port Valve |
| Application | Single Use / Unit for Manifold Mounting | Single Use | Single Use | Single Use / Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Single Use / Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting | Unit for Manifold Mounting |
| Switching Type | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center | 2-Position Normally Open / 2-Position Normally Closed | 2-Position Normally Open / 2-Position Normally Closed | 2-Position Exhaust / 3-Position Closed Center | 2-Position Normally Open / 2-Position Normally Closed | 2-Position Normally Open / 2-Position Normally Closed | 2-Position Exhaust / 3-Position Closed Center / 3-Position Exhaust Center / 3-Position Pressure Center | 2-Position Exhaust | 2-Position Exhaust / 3-Position Closed Center / Others | 2-Position Exhaust | 2-Position Normally Closed |
| Voltage | DC12V | DC12V | DC12V | DC12V | DC12V | DC12V | DC12V | DC12V | DC12V | DC12V | DC12V |
| Number of Solenoids | Single / Double | Single | Single | Single / Double | Single | Single | Single / Double | Double | Single / Double | Single | Single / Double |
| Mounting Orientation | Direct / Manifold Base | Direct | Direct | Direct / Manifold Base | Direct / Manifold Base | Direct / Manifold Base | Direct / Manifold Base | Manifold Base | Manifold Base | Manifold Base | Manifold Base |
| Pipe Port Type | Rc (R) / NPT / NPTF / G / One-Touch Plumbing | M / Rc (R) | Rc (R) / G | Rc (R) | M | M | Rc (R) / NPT / NPTF / G | - | One-Touch Plumbing | - | - |
| Specifications | Standard | Lubrication Free / Cleanroom | Lubrication Free / Cleanroom | Lubrication Free / Cleanroom | Lubrication Free / Cleanroom | Lubrication Free / Cleanroom | Lubrication Free | Standard / Lubrication Free | Lubrication Free | Lubrication Free | Lubrication Free |
| Status at Power Off | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Recovery (Spring Return) | Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Recovery (Spring Return) | Self-Recovery (Spring Return) | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Retaining | Self-Retaining / Self-Recovery (Spring Return) / Self-Recovery (Pressure Differential Return) | Self-Recovery (Spring Return) | Self-Recovery (Pressure Differential Return) |
| Plumbing Thread Nominal | 1/2 ~ 3/8 | 1/8 ~ M5 | 1/4 ~ 1/8 | 1/4 ~ 3/8 | M3 | M3 | 1/2 ~ 3/8 | - | - | - | - |
| Plumbing | Direct Plumbing / Sub-Base Plumbing | Direct Plumbing / Sub-Base Plumbing | Direct Plumbing / Sub-Base Plumbing | Sub-Base Plumbing | Direct Plumbing / Sub-Base Plumbing | Direct Plumbing / Sub-Base Plumbing | Sub-Base Plumbing | Sub-Base Plumbing | Direct Plumbing | Sub-Base Plumbing | Sub-Base Plumbing |
| Applicable Cylinder Dia.(Ø) | 80 or Less ~ 125 or less | - | - | 63 or less ~ 80 or Less | - | - | - | - | - | 40 or less ~ 50 or Less | 20 or Less |
| Type | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves | Solenoid Valves |
| Driving Type | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool | Pilot Type Spool |
| Connecting Tube Diameter | Ø4 / Ø6 / Ø8 / Ø10 / Ø12 / Ø1/4 / Ø3/8 | - | - | - | - | - | - | - | Ø4 / Ø6 | - | - |
| Pressure Rating(MPa) | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 / -0.1 to 0.7 | 0.15 to 0.7 | 0.15 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 / -0.1 to 0.7 | 0 to 0.7 | 0 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 / -0.1 to 0.7 | 0.2 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 / 0.2 to 0.7 | 0.15 to 0.7 | 0.15 to 0.7 / 0.1 to 0.7 |
| Seal Type | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Soft Seal | Standard | Soft Seal | Soft Seal |
| CV Value | 0.19 ~ 2.2 | 0.14 ~ 0.32 | 0.7 ~ 0.77 | 0.18 ~ 1.2 | 0.008 | 0.012 | 0.44 ~ 2.2 | 0.11 | 0.14 ~ 0.18 | - | - |
| Pilot Air Supply | Internal / External | Internal | Internal | Internal / External | Internal | Internal | Internal / External | Internal | Internal | Internal | Internal |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy