(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
| Days to Ship |
|
|---|

PARKERKURODA
This is a hi-rotor with flexible mount type that can be mounted in any direction freely, using the mounting holes located on the body.
| Standard Price: | MYR 1,648.08- |
|---|---|
| Days to Ship: | 7 Day(s) or more |

Rotary Actuator, Vane Type, CRB2 Series
SMC
Can be combined freely with many kinds of unit.
[Features]
· Piping port parts are located on the flat section.
· Many variations of shaft-end shape (6 types).
· Works with the compact auto switch D-M9□ type.
| Standard Price: | MYR 1,011.67- |
|---|---|
| Days to Ship: | 3 Day(s) or more |

Small High Rotor / Standard Type, PRNA Series (Single Vane / Double Vane)
PARKERKURODA
Prevents air leakage, improves the minimum operating pressure from 0.2MPa to 0.1MPa, and doubles the maximum oscillation time, thereby increasing the scope of possible applications. 2MPato 0.1MPa and extends the longest oscillating time to 2 times more than traditional. Controls ejection phenomenon to obtain smooth operation.
| Standard Price: | MYR 1,199.73- |
|---|---|
| Days to Ship: | 7 Day(s) or more |

Free Mount Type Rotary Actuator, Vane Type, CRBU2 Series
SMC
Can be combined freely with many kinds of unit.
[Features]
· Boasts a 12% weight reduction.
· Multiple mounting variations.
· Works with the compact auto switch D-M9□ type.
· Possible to move the plate mounting position as desired.
· Mounting pitch compatible with existing models.
· Rotation angles of 90°, 180° and 270°; all of the series can rotate up to 270°.
| Days to Ship: | 3 Day(s) or more |
|---|

Rotary Actuator With Angle Adjuster, Vane Type, CRB2□WU Series
SMC
Can be combined freely with many kinds of unit.
[Features]
With angle adjuster.
· Piping port parts are located on the flat section.
· Many variations of shaft-end shape (6 types).
· Works with the compact auto switch D-M9□ type.
| Standard Price: | MYR 1,346.33- |
|---|---|
| Days to Ship: | 3 Day(s) or more |

Large Therex Rotary Vane Type, Standard
CKD
100N/m (single) 200N/m (double) are added to the series of proven rotary vane types.
| Days to Ship: | 17 Day(s) or more |
|---|

Free Mount Type Rotary Actuator With Angle Adjuster, Vane Type, CRBU2WU Series
SMC
Can be combined freely with many kinds of unit.
[Features]
With angle adjuster.
· · Boasts a 12% weight reduction.
· Multiple mounting variations.
· Works with the compact auto switch D-M9□ type.
· Possible to move the plate mounting position as desired.
· Mounting pitch compatible with existing models.
· Rotation angles of 90°, 180° and 270°; all of the series can rotate up to 270°.
| Standard Price: | MYR 1,334.13- |
|---|---|
| Days to Ship: | 27 Day(s) or more |

Rotary Actuator, Vane Type, CRB1 Series
SMC
[Features]
· Works with the model D-M9□ compact auto switch.
· Highly reliable.
· Supports thrust and radial loads and uses bearings.
· The body can be mounted directly.
· 2 types of port location; side ported or axial ported.
| Standard Price: | MYR 1,033.74- |
|---|---|
| Days to Ship: | 3 Day(s) or more |

Basic Rotary Table, Vane Type, MSUB Series
SMC
A rotary actuator with a lightweight and compact table, suitable for robot hands.
[Features]
· Free mount type.
· Can be mounted in 3 directions; axial, lateral, vertical.
· Single vane and double vane types now standard.
· The double vane type has the same dimensions as the single vane type.
| Standard Price: | MYR 1,946.03- |
|---|---|
| Days to Ship: | 14 Day(s) or more |

ATEX Directive, Rotary Actuator, Vane Type 56-CRB1 Series, ATEX Category 3
SMC
[What is the ATEX directive?]
Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.
■CE mark and ATEX
The ATEX Directive is now part of the CE mark, which incorporates the conventional European explosion-proof standard.
■Purpose of ATEX Directive
The main purposes of ATEX are:
・ Prevention of static charge
・ Ignition prevention of sparks caused by friction, impact, and wear
・ Ignition prevention due to temperature rise due to the same as above
・ The responsibility lies with the manufacturer
・ Certification by zone/category
■Zone / category division
In ATEX, the objects to be applied are classified into categories according to the category of dangerous places (zone).
・ Zone 0: Category 1
Probability of explosive atmosphere (Zone): Continuous or long time, > 1,000 hours/year
・ Zone 1: Category 2
Probability of explosive atmosphere (Zone): Occasionally, 10 to 1,000 hours/year
・ Zone 2: Category 3
Probability of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
| Days to Ship: | Quote |
|---|

Rotary Actuator With Solenoid Valve, Vane Type, CVRB1 Series
SMC
Rotary actuator with solenoid valve.
[Features]
·2 types of port positions, body side and axial direction
·Mounting method: Direct mounting / foot type mounting
·Auto switch: None (no symbol), with auto switch (D)
·Size: 50, 63, 80, 100
·Vane type: Single vane, double vane
·Rotating angle: 90°, 100°, 180°, 190°, 270°, 280°, 45°, 135°
| Days to Ship: | 27 Day(s) or more |
|---|

Rotary Table, Vane Type Rechargeable Battery Compatible 25A-MSUB Series
SMC
[Rechargeable battery compatible series]
Copper (Cu) and zinc (Zn) materials are not used to reduce product defects in the rechargeable battery manufacturing process.
Some aluminum alloys and die-cast aluminum materials contain small amounts of copper (Cu) and zinc (Zn) as additive elements.
Electrolytic nickel plating and zinc plating with copper base are not used. (Electrolytic nickel plating is used. )
This product uses low dew point compatible grease, can be used at -70°C, improved performance in low dew point environment.
| Days to Ship: | 27 Day(s) or more |
|---|

Rotary Actuator, Vane Type, Clean and Low Dust Generation 10-/21-CRB1 Series
SMC
[10-Series Clean Series]
・ This product can be used in a clean environment
・ Prevents dust generation in the cleanroom
[21-Series, Copper-Free/ Fluorine-Free/ Silicone Type-Free + Low Dust Generation]
・ This product can be used in environments with restrictions on copper-based, fluorine-based, and silicone-based materials
・ The structure is the same as the Clean Series (Grease and packaging are different from the Clean Series)
| Days to Ship: | 27 Day(s) or more |
|---|

ATEX Directive, Rotary Actuator, Vane Type 55-CRB1 Series, ATEX Category 2
SMC
[What is the ATEX directive?]
Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.
■CE mark and ATEX
The ATEX Directive is now part of the CE mark, which incorporates the conventional European explosion-proof standard.
■Purpose of ATEX Directive
The main purposes of ATEX are:
・ Prevention of static charge
・ Ignition prevention of sparks caused by friction, impact, and wear
・ Ignition prevention due to temperature rise due to the same as above
・ The responsibility lies with the manufacturer
・ Certification by zone/category
■Zone / category division
In ATEX, the objects to be applied are classified into categories according to the category of dangerous places (zone).
・ Zone 0: Category 1
Probability of explosive atmosphere (Zone): Continuous or long time > 1,000 hours/year
・ Zone 1: Category 2
Probability of explosive atmosphere (Zone): Occasionally 10 to 1,000 hours/year
・ Zone 2: Category 3
Probability of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
| Days to Ship: | Quote |
|---|

ATEX Directive, Rotary Actuator, Vane Type 55-CRB2 Series, ATEX Category 2
SMC
[What is the ATEX directive?]
Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.
■CE mark and ATEX
The ATEX Directive is now part of the CE mark, which incorporates the conventional European explosion-proof standard.
■Purpose of ATEX Directive
The main purposes of ATEX are:
・ Prevention of static charge
・ Ignition prevention of sparks caused by friction, impact, and wear
・ Ignition prevention due to temperature rise due to the same as above
・ The responsibility lies with the manufacturer
・ Certification by zone/category
■Zone / category division
In ATEX, the objects to be applied are classified into categories according to the category of dangerous places (zone).
・ Zone 0: Category 1
Probability of explosive atmosphere (Zone): Continuous or long time, > 1,000 hours/year
・ Zone 1: Category 2
Probability of explosive atmosphere (Zone): Occasionally, 10 to 1,000 hours/year
・ Zone 2: Category 3
Probability of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
| Days to Ship: | Quote |
|---|

ATEX Directive, Rotary Actuator, Vane Type 56-CRB2 Series, ATEX Category 3
SMC
[What is the ATEX directive?]
Since July 1, 2003, it has been mandatory within the EU to comply with the ATEX Directive for equipment used in potentially explosive atmospheres.
■CE mark and ATEX
The ATEX Directive is now part of the CE mark, which incorporates the conventional European explosion-proof standard.
■Purpose of ATEX Directive
The main purposes of ATEX are:
・ Prevention of static charge
・ Ignition prevention of sparks caused by friction, impact, and wear
・ Ignition prevention due to temperature rise due to the same as above
・ The responsibility lies with the manufacturer
・ Certification by zone/category
■Zone / category division
In ATEX, the objects to be applied are classified into categories according to the category of dangerous places (zone).
・ Zone 0: Category 1
Probability of explosive atmosphere (Zone): Continuous or long time > 1,000 hours/year
・ Zone 1: Category 2
Probability of explosive atmosphere (Zone): Occasionally 10 to 1,000 hours/year
・ Zone 2: Category 3
Probability of explosive atmosphere (Zone): Less likely, short time < 10 hours/year
| Days to Ship: | Quote |
|---|
| Brand |
|---|
| Product Series |
| CAD |
| Days to Ship |
| Type |
| Main Body Shape |
| Oscillation Angle A |
| Torque(N・m) |
| Operation Method |
| Environment, Applications |
| Rigidity, Accuracy |
| Tube Nominal Dia. |
| Valves |
| Allowable Kinetic Energy(J) |
| Brand | PARKERKURODA | SMC | PARKERKURODA | SMC | SMC | CKD | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC | SMC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Product Series | Small High Rotor / Standard Type, PRNA Series (Single Vane / Double Vane) | Rotary Actuator With Angle Adjuster, Vane Type, CRB2□WU Series | Free Mount Type Rotary Actuator With Angle Adjuster, Vane Type, CRBU2WU Series | ATEX Directive, Rotary Actuator, Vane Type 56-CRB1 Series, ATEX Category 3 | Rotary Actuator With Solenoid Valve, Vane Type, CVRB1 Series | Rotary Table, Vane Type Rechargeable Battery Compatible 25A-MSUB Series | Rotary Actuator, Vane Type, Clean and Low Dust Generation 10-/21-CRB1 Series | ATEX Directive, Rotary Actuator, Vane Type 55-CRB1 Series, ATEX Category 2 | ATEX Directive, Rotary Actuator, Vane Type 55-CRB2 Series, ATEX Category 2 | ATEX Directive, Rotary Actuator, Vane Type 56-CRB2 Series, ATEX Category 3 | ||||||
| CAD |
|
|
|
|
|
|
|
|
| |||||||
| Days to Ship | 7 Day(s) or more | 3 Day(s) or more | 7 Day(s) or more | 3 Day(s) or more | 3 Day(s) or more | 17 Day(s) or more | 27 Day(s) or more | 3 Day(s) or more | 14 Day(s) or more | Quote | 27 Day(s) or more | 27 Day(s) or more | 27 Day(s) or more | Quote | Quote | Quote |
| Type | Rotary Actuator One Side Shaft Output | Rotary Actuator One Side Shaft Output / Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator One Side Shaft Output | Rotary Actuator One Side Shaft Output / Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator One Side Shaft Output / Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator One Side Shaft Output / Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator One Side Shaft Output / Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator One Side Shaft Output / Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator One Side Shaft Output | Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator One Side Shaft Output / Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator One Side Shaft Output | Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator Both Sides Shaft Outputs | Rotary Actuator Both Sides Shaft Outputs |
| Main Body Shape | Round Shape | Round Shape | Round Shape | Round Shape Block Mount | Round Shape | Round Shape | Round Shape Block Mount | Round Shape / Block Shape | Round Shape | Round Shape | Block Shape | Round Shape | Round Shape | Round Shape | Round Shape | Round Shape |
| Oscillation Angle A | 90° / 100° | 90° / 100° | 90° | 90° / 100° | 90° / 100° | - | 90° / 100° | 90° / 100° | 90° | 90° / 100° | 90° / 100° | 90° | 90° / 100° | 90° / 100° | 90° | 90° |
| Torque(N・m) | 3 ~ Less than 6 / 6 to Less Than 10 / 10 ~ Less than 20 / 20 to Less Than 50 / 50 to Less Than 100 / 100 ~ | Less than 1 / 1 to Less Than 3 / 3 ~ Less than 6 / 6 to Less Than 10 / 10 ~ Less than 20 | Less than 1 / 1 to Less Than 3 / 3 ~ Less than 6 / 6 to Less Than 10 / 10 ~ Less than 20 | Less than 1 / 1 to Less Than 3 / 3 ~ Less than 6 / 6 to Less Than 10 / 10 ~ Less than 20 | Less than 1 / 1 to Less Than 3 / 3 ~ Less than 6 / 6 to Less Than 10 / 10 ~ Less than 20 | 10 ~ Less than 20 / 20 to Less Than 50 / 50 to Less Than 100 / 100 ~ | Less than 1 / 1 to Less Than 3 / 3 ~ Less than 6 / 6 to Less Than 10 / 10 ~ Less than 20 | Less than 1 / 1 to Less Than 3 / 3 ~ Less than 6 / 6 to Less Than 10 / 10 ~ Less than 20 / 20 to Less Than 50 / 50 to Less Than 100 / 100 ~ | Less than 1 / 1 to Less Than 3 / 3 ~ Less than 6 / 6 to Less Than 10 / 20 to Less Than 50 | 50 to Less Than 100 | 3 ~ Less than 6 / 6 to Less Than 10 / 10 ~ Less than 20 / 20 to Less Than 50 / 50 to Less Than 100 / 100 ~ | 1 to Less Than 3 / 3 ~ Less than 6 / 6 to Less Than 10 / 20 to Less Than 50 | Less than 1 / 1 to Less Than 3 / 3 ~ Less than 6 / 6 to Less Than 10 / 10 ~ Less than 20 / 20 to Less Than 50 | 20 to Less Than 50 / 100 ~ | 10 ~ Less than 20 | 1 to Less Than 3 |
| Operation Method | Double Vane | Double Vane | Double Vane | Double Vane | Double Vane | Double Vane | Double Vane | Double Vane | Double Vane | Double Vane | Double Vane | Double Vane | Double Vane | Double Vane | Double Vane | Double Vane |
| Environment, Applications | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Copper-Based / fluoropolymer-Based Material Not Used (Partially Platting Supported) / Cleanroom | Standard | Standard | Standard |
| Rigidity, Accuracy | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard |
| Tube Nominal Dia. | - | 10 ~ 40 | - | 10 ~ 40 | 10 ~ 40 | 90 ~ 100 | 10 ~ 40 | 50 ~ 100 | 9 ~ 16 | - | 50 ~ 100 | - | - | - | - | - |
| Valves | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A / Provided | N/A | N/A | N/A | N/A | N/A |
| Allowable Kinetic Energy(J) | 0.01 to Less Than 0.1 / 0.1 to Less Than 1 / 1 ~ Less than 50 | Less than 0.005 / 0.01 to Less Than 0.1 | Less than 0.005 / 0.01 to Less Than 0.1 | Less than 0.005 / 0.01 to Less Than 0.1 | Less than 0.005 / 0.01 to Less Than 0.1 | - | Less than 0.005 / 0.01 to Less Than 0.1 | 0.1 to Less Than 1 | 0.005 to Less Than 0.01 / 0.01 to Less Than 0.1 | 0.1 to Less Than 1 | 0.1 to Less Than 1 | - | Less than 0.005 / 0.005 to Less Than 0.01 / 0.1 to Less Than 1 | 0.1 to Less Than 1 | 0.01 to Less Than 0.1 | Less than 0.005 |
Loading...
There might be logical torque values. Please refer to technical data of each manufacturer for details
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy