| Days to Ship |
|
|---|

Refrigerated Air Dryer Standard Temperature Air Inlet, IDF□E Series
SMC
Refrigerated air dryer with improved corrosion resistance due to the use of a stainless-steel heat exchanger.
[Features]
· Protects pneumatic equipment from moisture.
· Removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment to fail.
· Air flow capacity increased up to 40%.
· Power consumption reduced up to 40%.
· Energy-saving design.
· Exhaust heat reduced by 25%, controlling increases in ambient temperature (air-cooled specification) and reducing heat discharging water amount (water-cooled specification).
· Inlet air temperature: 35°C (22E, 37E) / 40°C (55E, 75E).
· Outlet air pressure dew point: 10°C.
| Days to Ship: | 21 Day(s) or more |
|---|
| Brand |
|---|
| Product Series |
| CAD |
| Days to Ship |
| Type |
| Method |
| Shape |
| Unit Combination |
| Outlet Flow Rate(l/min) |
| Outlet Open Air Pressure Dew-point(℃) |
| Supply Side, Connection Type |
| Inlet Air Temperature(℃) |
| Inlet Air Pressure(MPa) |
| Supply Side, Plumbing Thread Nominal |
| Supply Side, Connecting Tube Diameter |
| Supply Side, Tube Flange Nominal |
| Control Side, Connection Type |
| Control Side, Plumbing Thread Nominal |
| Control Side, Connecting Tube Diameter |
| Control Side, Tube Flange Nominal |
| Exit Flow Rate [Distinction](l/min) |
| Brand | SMC |
|---|---|
| Product Series | Refrigerated Air Dryer Standard Temperature Air Inlet, IDF□E Series |
| CAD |
|
| Days to Ship | 21 Day(s) or more |
| Type | Dryers |
| Method | Freezing Type |
| Shape | Standard |
| Unit Combination | - |
| Outlet Flow Rate(l/min) | 11,000 ~ 12,400 |
| Outlet Open Air Pressure Dew-point(℃) | 10 |
| Supply Side, Connection Type | Rc(R) |
| Inlet Air Temperature(℃) | 40 |
| Inlet Air Pressure(MPa) | 0.7 |
| Supply Side, Plumbing Thread Nominal | 2 |
| Supply Side, Connecting Tube Diameter | - |
| Supply Side, Tube Flange Nominal | - |
| Control Side, Connection Type | Rc(R) |
| Control Side, Plumbing Thread Nominal | 2 |
| Control Side, Connecting Tube Diameter | - |
| Control Side, Tube Flange Nominal | - |
| Exit Flow Rate [Distinction](l/min) | More than 5000 |
Loading...
* ~5 represents over 1, and 5 or less.
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy