(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
| Days to Ship |
|
|---|

Oil Mist Filter (Modular-Type Standard) M*000 Series
CKD
Modular design. Removes oils and oil mist effectively.
| Days to Ship: | 14 Day(s) or more |
|---|

Oil Mist Filter M1000/2000/3000/4000/6000/8000-W-FP1 Series
CKD
It supports food manufacturing.
Food-grade lubricant (NSF H1) is used for the flow path and sliding parts.
SELEX FRL is a full-fledged module series that pursues high performance in all, such as functionality, operability, maintainability and safety by the modular design in which the main dimensions (width and depth) of each device such as filter (F), regulator (R) and lubricator (L) are unified.
[Features]
・ Compact and modular type with unified main dimensions for filter regulators, lubricators, etc.
・ Uses aluminum body and resin cover
・ A lightweight type that also has strength
・ Clean air, oilless air, etc., can be supplied according to the application and purpose
・ It is possible to combine according to the application
・ Significant elimination of clogging due to unique chemical fiber structure
・ A neat design that does not require useless space on the front
| Days to Ship: | 17 Day(s) or more |
|---|

Air Filter F1000/2000/3000/4000/6000/8000-W-FP1 Series
CKD
It supports food manufacturing.
Food-grade lubricant (NSF H1) is used for the flow path and sliding parts.
[Features]
· Modular design
・ Long lifespan with dual element structure
・ O-ring fall prevention
・ Filter element with integrated single-action connection and disconnection
・ Series of 5-μm element for dust removal, and 0.3-μm element for tar removal
・ (Excluding F1000 series)
・ Connection Port Diameter: 1/8 to 1
| Days to Ship: | 17 Day(s) or more |
|---|

Air Filter (Modular Type, Standard) F*000 Series
CKD
Modular design. Long life with a double element structure. O-ring drop prevention. Filter element with integrated one-touch connection and disconnection
| Days to Ship: | 13 Day(s) or more |
|---|

CKD
It supports food manufacturing.
Food-grade lubricant (NSF H1) is used for the flow path and sliding parts.
Modular design.
High performance and 10 times the oil removal ability.
Long life and low pressure loss.
Secondary oil concentration 0.001 mg/m^3
Ideal for optical devices such as optical positioning devices and laser machines.
| Days to Ship: | 17 Day(s) or more |
|---|

CKD
[Features]· Reliable "antimicrobial" and "disinfectant" powers· Sterilization active value of 3 and bacteria trapping performance of LRV8 or higher.· Uses material compliant with the Food Sanitation Act of Japan· NSF H1 grease for food products used· Antibacterial materials used for the exterior.
| Standard Price: | MYR 3,179.17 |
|---|---|
| Days to Ship: | 11 Day(s) or more |

CKD
[Features]· Reliable "antimicrobial" and "disinfectant" powers· Sterilization active value of 3 and bacteria trapping performance of LRV8 or higher.· Uses material compliant with the Food Sanitation Act of Japan· NSF H1 grease for food products used· Antibacterial materials used for the exterior.
| Standard Price: | MYR 2,364.56 |
|---|---|
| Days to Ship: | 21 Day(s) or more |

CKD
[Features]· Reliable "antimicrobial" and "disinfectant" powers· Sterilization active value of 3 and bacteria trapping performance of LRV8 or higher.· Uses material compliant with the Food Sanitation Act of Japan· NSF H1 grease for food products used· Antibacterial materials used for the exterior.
| Standard Price: | MYR 1,412.50 |
|---|---|
| Days to Ship: | 27 Day(s) or more |
| Brand |
|---|
| Product Series |
| CAD |
| Days to Ship |
| Filtration Level |
| Plumbing Thread Nominal |
| Compressed Air Quality |
| Type |
| Connection Type |
| Treatment Air Flow Rate(l/min) |
| Operating Environment |
| Drain Cock |
| Bowl Material |
| Bowl Guard |
| Microbial Removal Performance |
| Brand | CKD | CKD | CKD | CKD | CKD | CKD | CKD | CKD |
|---|---|---|---|---|---|---|---|---|
| Product Series | ||||||||
| CAD |
|
|
|
|
| |||
| Days to Ship | 14 Day(s) or more | 17 Day(s) or more | 17 Day(s) or more | 13 Day(s) or more | 17 Day(s) or more | 11 Day(s) or more | 21 Day(s) or more | 27 Day(s) or more |
| Filtration Level | 0.01µm / 0.3µm | - | - | 0.3µm / 5µm | 0.01µm | 0.01µm | 0.01µm | 0.01µm |
| Plumbing Thread Nominal | 1/4 / 3/8 | - | - | 1/4 / 3/8 | - | 1/4 / 3/8 | 1/4 / 3/8 | 3/8 |
| Compressed Air Quality | General Quality Dry Air / Oil Containing Air | General Quality Dry Air / Oil Containing Air | General Quality Dry Air | General Quality Dry Air | General Quality Dry Air / Oil Containing Air | Particle / Mold Containing | Particle / Mold Containing | Particle / Mold Containing |
| Type | Standard | Standard | Standard | Standard | Standard | Standard | Standard | Standard |
| Connection Type | Rc (R) / NPT / G | - | - | Rc (R) / NPT / G | - | - | - | - |
| Treatment Air Flow Rate(l/min) | - | - | - | - | - | 300 | 360 | 300 |
| Operating Environment | - | - | - | - | - | - | - | - |
| Drain Cock | Manual Type / Auto Float Type | - | - | Manual Type / Auto Float Type | - | Not Provided | Not Provided | Not Provided |
| Bowl Material | Plastic / Metal | - | - | Plastic / Metal | - | Plastic | Plastic | Plastic |
| Bowl Guard | Provided | Provided | Provided | Provided | Provided | Provided | Provided | Provided |
| Microbial Removal Performance | - | - | - | - | - | LRV≧8 | LRV≧8 | LRV≧8 |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy