Control/Instrumentation Cables(Drain Wire:N/A)

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 2 Day(s) or Less
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • 10 Day(s) or Less
  • 11 Day(s) or Less
  • 12 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials
Drain Wire
Wire Standard

    Cable for electronic equipment wiring CM/2464-1061/IIA LF Series (shielded and non-shielded)

    Brand

    TAIYO CABLETEC

    Product Series

    Cable for electronic equipment wiring CM/2464-1061/IIA LF Series (shielded and non-shielded)

    Days to Ship 10 Day(s) or more
    Overall Length(m)1 ~ 100
    Specified Length(m)-
    Conductor Cross Section(mm2)0.0804 ~ 0.204
    AWG size(AWG)24 ~ 28
    Number Of Cores(Core)2 ~ 60
    Logarithm1P ~ 30P
    Finished outer diameter(mm)3.9 ~ 14.3
    Rated Voltage300V
    ShieldAvailable / NA
    PropertiesOil Resistance / Heat-Resistance
    Representative StandardCSA(c-UL) / UL LISTED
    Sheath (outer coating) colorBlack
    Grounding WireNA
    Sheath (outer coating) materialPVC (Polyvinyl Chloride)
    Insulation body materialsPVC (Polyvinyl Chloride)
    Drain WireN/A
    Wire Standard-