UL Listed Unshielded Instrumentation Cable
TACHIDENSEN
UL compliant unshielded instrumentation cable U-TKVV series
[Features]
· A UL listing (ULPLCC), UL recognized (ULAWM), cUL (CSAAWM) multi-standard cable.
· Cable compatible with NFPA79.
· Superior heat resistance, oil resistance, and flexibility.
· A wide range of products are available, distinguished by different conductor sizes (AWG 24-AWG 16), number of center strands, and presence or absence of braided shield.
· Because a twister pair type is set at a different pitch than adjacent pairs, crosstalk noise can be reduced.
· Braid shielded type cable has a drain wire of the same size as the conductor.
· Shield connection is easy.
· Conductor size and number of core wires (pairs) are printed on cable surface.
· Makes cable identification easy.
| Standard Price: | MYR 22.92- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
300 V cable for fixed signals, CL3/ULAWM2464 standard compliant. A sheath with excellent oil resistance and flexibility is used.
| Standard Price: | MYR 14.16- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NASE Series Wire Core ID for Sensor
MISUMI
ULAWM standard compliant cable for UL standard control equipment sensors, with excellent oil resistance and heat resistance. Three types are available: for fixed general wiring, for sputtering, and for movable use.
| Standard Price: | MYR 9.31- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
300 V cable for fixed signals, ULAWM2517 standard compliant, with excellent oil resistance.
| Standard Price: | MYR 9.45- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

Twisted Pair Instrumentation Cable
TACHIDENSEN
Twisted pair Instrumentation cable TKVVBS series
[Features]
· Superior heat resistance, oil resistance, and flexibility.
· Twisted layer types and twisted pair types are available.
· Because a twisted pair type is set at a different pitch to adjacent pairs, crosstalk noise can be reduced.
· A braided shield is provided as a noise countermeasure.
· Shield wiring work can be performed easily thanks to a drain wire of the same size as the conductor.
| Standard Price: | MYR 27.05- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)
BANDO DENSEN
Suitable for wiring of electrical and electronic equipment subject to UL (AWM)/cUL (CSA)/NFPA (70/79) standards (unshielded type).
[Features]
· Uses UL (AWM), cUL (CSA), and NFPA (70/79) standards.
· Flame retardancy is UL: VW-1, CL2, CL3, cUL (CSA): FT1/FT2..
· High-density braid shielding.
| Standard Price: | MYR 11.23- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
150 V Cable for UL-AWM Standard Signals
| Standard Price: | MYR 533.55- |
|---|---|
| Days to Ship: | 2 Day(s) |

TAIYO CABLETEC
UL VW-1 and cUL FT1 compliant flame retardant cable
[Features]
· UL VW-1 and cUL FT1 (category QPTZ, AVLV2, AVLV7) compliant flame retardancy.
▪ Passed UL vertical tray flame retardancy test.
· Uses an oil, heat, and flame resistant flexible vinyl sheath material.
· Also usable as tray cable.
· RS485, RS422, and RS232C compatible cable.
· Certified to listing standard CL2 and suitable for NFPA70.
| Standard Price: | MYR 31.31- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

VVC Highly Flame-Retardant NEC Standard Cable (Unshielded)
BANDO DENSEN
Suitable for wiring of electrical and electronic equipment subject to the UL (AWM), NFPA (70, 79) standards (unshielded type).
[Features]
▪ Approved by UL (AWM), NFPA (70, 79) standards.
· Flame retardancy UL: VW-1, CL2, CL3.
· High-density braid shielding.
| Standard Price: | MYR 10.81- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

BIOS Highly Flame Retardant NEC Standard Cable (Shielded)
BANDO DENSEN
High density braid shielding suitable for wiring of electrical and electronic equipment subject to UL (AWM)/cUL (CSA)/NFPA (70/79) standards.
[Features]
· Uses UL (AWM), cUL (CSA), and NFPA (70/79) standards.
· Flame retardancy is UL: VW-1, CL2, CL3, cUL (CSA): FT1/FT2..
· High-density braid shielding.
| Standard Price: | MYR 27.29- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NA20276H Cross-Linked Polyethylene UL-Supported
MISUMI
30 V cable that can be purchased at a lower price than similar products., ULAWM20276 standard compliant. Cross-linked polyethylene, which is ideal for signal transmission of measuring instrument with excellent oil resistance, is used for insulation.
| Standard Price: | MYR 857.18- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NA3VCSB UL Standard with Shield
MISUMI
300 V oil-resistant shielded cable for fixed signals, ULAWM2517 standard compliant.
| Standard Price: | MYR 17.96- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
ULAWM standard compliant shielded composite cable for servo encoders/stepping that can be used for fixed and movable applications.
| Days to Ship: | 4 Day(s) or more |
|---|

KURAMO ELECTRIC
Suitable for wiring of control circuit for machine tools
[Features]
· UL/cUL standard cable.
· Noise resistance.
· Flexibility.
· Oil resistance.
| Standard Price: | MYR 31.31- |
|---|---|
| Days to Ship: | 4 Day(s) or more |
| Standard Price: | MYR 41.51- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NAVCSB UL Standard with Shield
MISUMI
150 V fixed signal shielded cable for small diameter, ULAWM2576/ULAWM2095 standard compliant, with excellent oil resistance.
| Standard Price: | MYR 17.84- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NASWS UL Each Pair Triple-Shielded Aluminum Foil Tape
MISUMI
300 V cable, ULAWM2464 standard compliant, with excellent noise resistance. The triple shielded cable consists of aluminum foil tape, braided shield, and each pair of shields, to provide excellent noise prevention. Each pair is shielded (drain wire), so it is easy to perform machining in terminal works such as earth terminal connection.
| Standard Price: | MYR 1,320.77- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

300 V Shielded Cable for Signals
MISUMI
Shielded signal cable with fusion splicing for IDC connectors that uses 300 V cable compliant with the ULAWM2464 standard.
| Days to Ship: | 5 Day(s) or more |
|---|

Twisted Layer Instrumentation Cable
TACHIDENSEN
Twisted layer instrumentation cable, TKVVBS series
[Features]
· Has superior heat resistance, oil resistance, and flexibility.
· Twisted layer types and twisted pair types available.
· Because the twisted pair type is set at a different pitch than adjacent pairs, crosstalk noise can be reduced.
· Braided shield provided as noise countermeasure.
· Shield wiring work can also be performed easily because a drain wire the same size as the conductor is provided.
| Standard Price: | MYR 23.87- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

VSVC Highly Flame-Retardant NEC Standard Cable (Shielded)
BANDO DENSEN
Suitable for wiring of electrical and electronic equipment subject to UL (AWM)/NFPA (70/79) standards.
[Features]
· Uses UL (AWM) and NFPA (70/79) standards.
· Flame retardancy is UL: VW-1, CL2, CL3.
· High-density braid shielding.
| Standard Price: | MYR 19.66- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

SSCL3SB, UL-Listed (CL3) Support With Shield
MISUMI
300 V shielded cable for fixed signals, CL3/ULAWM2464 standard compliant. A sheath with excellent oil resistance and flexibility is used.
| Standard Price: | MYR 647.26- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NA20276HB Cross-Linked Polyethylene UL with Shield
MISUMI
30 V shielded cable that can be purchased at a lower price than similar products, compliant with ULAWM20276 standard. Cross-linked polyethylene, which is ideal for signal transmission of measuring instrument with excellent oil resistance, is used for insulation. Twisted pair and shield provides good noise prevention.
| Standard Price: | MYR 937.04- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
150 V fixed signal cable for small diameter, ULAWM2576/ULAWM2095 standard compliant, with excellent oil resistance.
| Standard Price: | MYR 8.00- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
300 V cable, ULAWM2464 standard compliant. A small diameter type with a braided shield for EMI shielding.
| Standard Price: | MYR 19.67- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NA28WSB UL 300 V 2-Shielded Cable
MISUMI
300 V cable, ULAWM2464 standard compliant. Excellent noise prevention effect is achieved by using a double shield consisting of aluminum foil tape and braided shield.
| Standard Price: | MYR 24.27- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NANB UL Each Pair Triple-Shielded Magnetic Foil Tape
MISUMI
300 V cable, ULAWM2464 standard compliant, with excellent noise resistance. The triple shield consists of magnetic foil tape, braided shield, and each pair of shields, to provide excellent noise prevention. Each pair is shielded (drain wire), so it is easy to perform machining in terminal works such as earth terminal connection.
| Standard Price: | MYR 6,420.17- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NA20276 UL Standard with Shield AWG28
MISUMI
30 V single shielded cable, ULAWM20276 standard compliant, with excellent oil resistance and noise resistance. Only AWG size 28 is available, and a braided shield is applied for EMI shielding.
| Standard Price: | MYR 1,268.29- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

30 V Shielded Cable for Signals
MISUMI
Shielded signal cable with fusion splicing for IDC connectors that uses 30 V cable compliant with the ULAWM20276 standard.
| Days to Ship: | 5 Day(s) or more |
|---|

TAIYO CABLETEC
Electronic equipment wiring cable UL20276
[Features]
· UL VW-1 (category AVLV2) compliant flame retardancy.
· Uses an oil, heat, and flame resistant flexible vinyl sheath material.
· Cable compatible with RS232.
· Ideal for insulation displacement type half pitch connector.
| Standard Price: | MYR 17.02- |
|---|---|
| Days to Ship: | 4 Day(s) or more |
| Brand |
|---|
| Product Series |
| Days to Ship |
| Specifications |
| Overall Length(m) |
| Specified Length(m) |
| Conductor Cross Section(mm2) |
| AWG size(AWG) |
| Number Of Cores(Core) |
| Logarithm |
| Finished outer diameter(mm) |
| Rated Voltage |
| Shield |
| Properties |
| Representative Standard |
| Sheath (outer coating) color |
| Grounding Wire |
| Sheath (outer coating) material |
| Insulation body materials |
| Drain Wire |
| Wire Standard |
| Brand | TACHIDENSEN | MISUMI | MISUMI | MISUMI | TACHIDENSEN | BANDO DENSEN | MISUMI | TAIYO CABLETEC | BANDO DENSEN | BANDO DENSEN | MISUMI | MISUMI | MISUMI | KURAMO ELECTRIC | HITACHI CABLE | MISUMI | MISUMI | MISUMI | TACHIDENSEN | BANDO DENSEN | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | TAIYO CABLETEC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Product Series | |||||||||||||||||||||||||||||
| Days to Ship | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 2 Day(s) | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 5 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 5 Day(s) or more | 4 Day(s) or more |
| Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
| Overall Length(m) | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 200 | 1 ~ 100 | 100 | 1 ~ 49 | 1 ~ 100 | 1 ~ 100 | 100 | 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 100 | 100 | 1 ~ 49 | 1 ~ 100 |
| Specified Length(m) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| Conductor Cross Section(mm2) | 0.22 ~ 0.54 | 0.2 ~ 0.5 | 0.08 ~ 0.5 | 0.2 ~ 1.25 | 0.2 ~ 0.5 | - | 0.2 | 0.204 ~ 0.823 | - | - | 0.12 ~ 0.3 | 0.2 ~ 1.25 | 0.12 ~ 0.32 | 0.5 | 0.12 ~ 0.2 | 0.12 ~ 0.5 | 0.2 | 0.08 | 0.2 ~ 0.3 | - | 0.2 ~ 0.5 | 0.12 ~ 0.3 | 0.12 ~ 0.5 | 0.08 | 0.08 | 0.2 | 0.08 | 0.08 | 0.0804 |
| AWG size(AWG) | 20 ~ 24 | 20 ~ 24 | 20 ~ 28 | 16 ~ 25 | 20 ~ 24 | 16 ~ 26 | 25 | 18 ~ 24 | 20 ~ 24 | 16 ~ 26 | 22 ~ 26 | 16 ~ 25 | 22 ~ 26 | 20 | 24 ~ 26 | 21 ~ 27 | 25 | 28 | 22 ~ 24 | 20 ~ 24 | 20 ~ 24 | 22 ~ 26 | 21 ~ 27 | 28 | 28 | 25 | 28 | 28 | 28 |
| Number Of Cores(Core) | 2 ~ 50 | 2 ~ 34 | 2 ~ 4 | 2 ~ 12 | 2 ~ 50 | 2 ~ 10 | - | - | 2 ~ 14 | 2 ~ 10 | 2 ~ 20 | 2 ~ 12 | 4 | 2 ~ 30 | 10 ~ 50 | - | - | - | 2 ~ 40 | 2 ~ 40 | - | 3 | - | - | - | - | - | - | 4 ~ 40 |
| Logarithm | 1P ~ 25P | - | - | 1P ~ 25P | 1P ~ 25P | 1P ~ 20P | 1P ~ 2P | 1P ~ 5P | - | 1P ~ 25P | - | 1P ~ 32P | 2 | 1P ~ 15P | 5P ~ 25P | 1P ~ 20P | 1P ~ 13P | 3P ~ 32P | - | - | 1P ~ 8P | 1P ~ 8P | 1P ~ 20P | 2P ~ 32P | 1P ~ 20P | 5P ~ 13P | 5P ~ 50P | 5P ~ 25P | 2P ~ 20P |
| Finished outer diameter(mm) | 4 ~ 15 | 4.1 ~ 11.2 | 2.8 ~ 6 | 3.9 ~ 14.1 | 4.6 ~ 15.9 | 4.1 ~ 17.6 | 3.1 ~ 5.2 | 5.1 ~ 14 | 4.9 ~ 8.9 | 4.7 ~ 18.3 | 3.7 ~ 8 | 4.4 ~ 14.6 | 5.5 ~ 9.3 | 4.8 ~ 14 | - | 3.7 ~ 14.2 | 4.5 ~ 11.7 | 6.3 ~ 14.1 | 4.6 ~ 11.6 | 5.5 ~ 13.7 | 4.7 ~ 9.6 | 4.3 ~ 11.1 | 2.9 ~ 15.3 | 6 ~ 14.1 | 4.5 ~ 11.7 | 8.5 ~ 11.8 | 5.1 ~ 10.4 | 5.1 ~ 8.1 | 4.2 ~ 7.5 |
| Rated Voltage | 300V | 300V | 300V / For Low Current Circuits | 300V | Other | 300V | For Low Current Circuits | For Low Current Circuits | 300V | 300V | For Low Current Circuits | 300V | 300V / For Low Current Circuits | For Low Current Circuits | 300V | For Low Current Circuits | 300V | 300V | Other | 300V | 300V | For Low Current Circuits | For Low Current Circuits | 300V | 300V | 300V | For Low Current Circuits | For Low Current Circuits | For Low Current Circuits |
| Shield | NA | NA | NA | NA | Available | NA | NA | Available | NA | Available | NA | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | Available | NA | Available | Available | Available | Available | Available | Available |
| Properties | Oil Resistance / Heat-Resistance | Oil Resistance | Oil Resistance | Oil Resistance | Oil Resistance / Heat-Resistance | Oil Resistance / Heat-Resistance | Oil Resistance | Oil Resistance / Heat-Resistance | Heat-Resistance | Oil Resistance / Heat-Resistance | Oil Resistance | Oil Resistance | - | Oil Resistance | Heat-Resistance | Oil Resistance | - | - | Oil Resistance / Heat-Resistance | Heat-Resistance | Oil Resistance | Oil Resistance | Oil Resistance | - | - | - | - | - | Oil Resistance / Heat-Resistance |
| Representative Standard | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL |
| Sheath (outer coating) color | Black | Black | Blue | Blue | Gray | Black | Black | Black | Gray | Black | Blue | Blue | Blue | Black | Gray | Blue | Blue | Blue | Black | Gray | Black | Blue | Blue | Blue | Blue | Blue | Blue | Blue | Black |
| Grounding Wire | NA | - | - | - | Other | - | - | NA | - | - | - | - | - | Other | - | - | - | - | Other | - | - | - | - | - | - | - | - | - | NA |
| Sheath (outer coating) material | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) |
| Insulation body materials | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) / Fluorine-Based | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | Polyethylene-Based | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | Polyethylene-Based | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) / Fluorine-Based | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | Polyethylene-Based | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) |
| Drain Wire | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| Wire Standard | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy