| Days to Ship |
|
|---|

UL Listed Unshielded Instrumentation Cable
TACHIDENSEN
UL compliant unshielded instrumentation cable U-TKVV series
[Features]
· A UL listing (ULPLCC), UL recognized (ULAWM), cUL (CSAAWM) multi-standard cable.
· Cable compatible with NFPA79.
· Superior heat resistance, oil resistance, and flexibility.
· A wide range of products are available, distinguished by different conductor sizes (AWG 24-AWG 16), number of center strands, and presence or absence of braided shield.
· Because a twister pair type is set at a different pitch than adjacent pairs, crosstalk noise can be reduced.
· Braid shielded type cable has a drain wire of the same size as the conductor.
· Shield connection is easy.
· Conductor size and number of core wires (pairs) are printed on cable surface.
· Makes cable identification easy.
| Standard Price: | MYR 44.95- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
300 V cable for fixed signals, ULAWM2517 standard compliant, with excellent oil resistance.
| Standard Price: | MYR 45.65- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

Twisted Pair Instrumentation Cable
TACHIDENSEN
Twisted pair Instrumentation cable TKVVBS series
[Features]
· Superior heat resistance, oil resistance, and flexibility.
· Twisted layer types and twisted pair types are available.
· Because a twisted pair type is set at a different pitch to adjacent pairs, crosstalk noise can be reduced.
· A braided shield is provided as a noise countermeasure.
· Shield wiring work can be performed easily thanks to a drain wire of the same size as the conductor.
| Standard Price: | MYR 87.71- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)
BANDO DENSEN
Suitable for wiring of electrical and electronic equipment subject to UL (AWM)/cUL (CSA)/NFPA (70/79) standards (unshielded type).
[Features]
· Uses UL (AWM), cUL (CSA), and NFPA (70/79) standards.
· Flame retardancy is UL: VW-1, CL2, CL3, cUL (CSA): FT1/FT2..
· High-density braid shielding.
| Standard Price: | MYR 33.04- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

BIOS Highly Flame Retardant NEC Standard Cable (Shielded)
BANDO DENSEN
High density braid shielding suitable for wiring of electrical and electronic equipment subject to UL (AWM)/cUL (CSA)/NFPA (70/79) standards.
[Features]
· Uses UL (AWM), cUL (CSA), and NFPA (70/79) standards.
· Flame retardancy is UL: VW-1, CL2, CL3, cUL (CSA): FT1/FT2..
· High-density braid shielding.
| Standard Price: | MYR 39.97- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NA3VCSB UL Standard with Shield
MISUMI
300 V oil-resistant shielded cable for fixed signals, ULAWM2517 standard compliant.
| Standard Price: | MYR 57.92- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

KURAMO ELECTRIC
Suitable for wiring of control circuit for machine tools
[Features]
· UL/cUL standard cable.
· Noise resistance.
· Flexibility.
· Oil resistance.
| Standard Price: | MYR 94.65- |
|---|---|
| Days to Ship: | 7 Day(s) or more |

NAVCSB UL Standard with Shield
MISUMI
150 V fixed signal shielded cable for small diameter, ULAWM2576/ULAWM2095 standard compliant, with excellent oil resistance.
| Standard Price: | MYR 71.06- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NASWS UL Each Pair Triple-Shielded Aluminum Foil Tape
MISUMI
300 V cable, ULAWM2464 standard compliant, with excellent noise resistance. The triple shielded cable consists of aluminum foil tape, braided shield, and each pair of shields, to provide excellent noise prevention. Each pair is shielded (drain wire), so it is easy to perform machining in terminal works such as earth terminal connection.
| Standard Price: | MYR 6,516.38 |
|---|---|
| Days to Ship: | 4 Day(s) or more |

300 V Shielded Cable for Signals
MISUMI
Shielded signal cable with fusion splicing for IDC connectors that uses 300 V cable compliant with the ULAWM2464 standard.
| Days to Ship: | 5 Day(s) or more |
|---|

SSCL3SB, UL-Listed (CL3) Support With Shield
MISUMI
300 V shielded cable for fixed signals, CL3/ULAWM2464 standard compliant. A sheath with excellent oil resistance and flexibility is used.
| Standard Price: | MYR 2,073.00 |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NA20276HB Cross-Linked Polyethylene UL with Shield
MISUMI
30 V shielded cable that can be purchased at a lower price than similar products, compliant with ULAWM20276 standard. Cross-linked polyethylene, which is ideal for signal transmission of measuring instrument with excellent oil resistance, is used for insulation. Twisted pair and shield provides good noise prevention.
| Standard Price: | MYR 3,870.70 |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
150 V fixed signal cable for small diameter, ULAWM2576/ULAWM2095 standard compliant, with excellent oil resistance.
| Standard Price: | MYR 35.69- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
300 V cable, ULAWM2464 standard compliant. A small diameter type with a braided shield for EMI shielding.
| Standard Price: | MYR 25.57- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NA28WSB UL 300 V 2-Shielded Cable
MISUMI
300 V cable, ULAWM2464 standard compliant. Excellent noise prevention effect is achieved by using a double shield consisting of aluminum foil tape and braided shield.
| Standard Price: | MYR 57.94- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NANB UL Each Pair Triple-Shielded Magnetic Foil Tape
MISUMI
300 V cable, ULAWM2464 standard compliant, with excellent noise resistance. The triple shield consists of magnetic foil tape, braided shield, and each pair of shields, to provide excellent noise prevention. Each pair is shielded (drain wire), so it is easy to perform machining in terminal works such as earth terminal connection.
| Standard Price: | MYR 9,166.67 |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NA20276 UL Standard with Shield AWG28
MISUMI
30 V single shielded cable, ULAWM20276 standard compliant, with excellent oil resistance and noise resistance. Only AWG size 28 is available, and a braided shield is applied for EMI shielding.
| Standard Price: | MYR 1,521.95 |
|---|---|
| Days to Ship: | 4 Day(s) or more |

30 V Shielded Cable for Signals
MISUMI
Shielded signal cable with fusion splicing for IDC connectors that uses 30 V cable compliant with the ULAWM20276 standard.
| Days to Ship: | 5 Day(s) or more |
|---|

Cable for factory automation electronic equipment wiring, KVC-36SB Series, shielded
KURAMO ELECTRIC
[Features]
· Noise resistance
· Flexibility
· Oil resistance
· UL and cUL standard cable
[Applications]
· Wiring to control circuits of machine tools
· Wiring in oil environments
· Wiring for locations requiring noise resistance
| Standard Price: | MYR 54.27- |
|---|---|
| Days to Ship: | 10 Day(s) or more |

KURAMO ELECTRIC
[Features]
·Flexibility.
·Oil resistance.
·UL/cUL standard cable.
[Applications]
·Wiring to the control circuit of the machine tool.
·Wiring in an oily environment.
·Please refer to the following for shielded products.
| Standard Price: | MYR 120.22- |
|---|---|
| Days to Ship: | 10 Day(s) or more |

Wiring cable for electronic devices HK-SB/20276 XL LF
TAIYO CABLETEC
[Features]
· Uses cross-linked polyethylene for the insulator.
· Uses oil resistant, heat resistant and flexible vinyl sheath material.
· Uses a separator that generates little dust.
· Includes drain wire.
· Compatible with UL VW-1 and cUL FT1 flame retardant.
[Applications]
· UL and cUL shared shielded device cable, rated at 30 V and 80°C (categories: AVLV2, AVLV8).
· RS485 and RS422 compatible cable.
| Standard Price: | MYR 151.02- |
|---|---|
| Days to Ship: | 10 Day(s) or more |

Wiring cable for electronic equipment HK/20276 XL LF
TAIYO CABLETEC
[Features]
· Uses cross-linked polyethylene for the insulator.
· Uses oil resistant, heat resistant and flexible vinyl sheath material.
· Uses a separator that generates little dust.
· Compatible with UL VW-1 and cUL FT1 flame retardant.
[Applications]
· UL and cUL shared cable rated at 30 V and 80°C (categories: AVLV2, AVLV8).
· RS485 and RS422 compatible cable.
| Standard Price: | MYR 135.77- |
|---|---|
| Days to Ship: | 12 Day(s) or more |

Cable for electronic equipment wiring CM/2464-1061/IIA LF Series (shielded and non-shielded)
TAIYO CABLETEC
[Features]
· Uses semi-rigid PVC for the insulator
· Uses oil resistant, heat resistant and flexible vinyl sheath material
· Compatible with UL VW-1 and cUL FT1 flame retardant
· Passed the UL vertical tray flame retardant test
[Applications]
· RS232C compatible cable (multi-pair cable only)
· Can also be used as a tray cable for communication
· Can be used as a substitute for UL13 CL3 and CL3X
· 300 V rated, 80°C, UL and cUL standard equipment cable
· Listing standard CM has been acquired and NFPA70 and 79 are supported
| Standard Price: | MYR 117.69- |
|---|---|
| Days to Ship: | 10 Day(s) or more |

Wiring cable for electronic equipment CM/2464-1007/IIA LF Series (shielded and non-shielded)
TAIYO CABLETEC
[Features]
· Heat resistant PVC is used for the insulator.
· Uses oil resistant, heat resistant and flexible vinyl sheath material
· Compatible with UL VW-1 and cUL FT1 flame retardant
· Passed the UL vertical tray flame retardant test
[Applications]
· Can also be used as a tray cable for communication
· Can be used as a substitute for UL13 CL3 and CL3X
· 300 V rated, 80°C, UL and cUL standard equipment cable
· Listing standard CM has been acquired and NFPA70 and 79 are supported
| Standard Price: | MYR 251.93- |
|---|---|
| Days to Ship: | 12 Day(s) or more |
| Brand |
|---|
| Product Series |
| Days to Ship |
| Specifications |
| Overall Length(m) |
| Specified Length(m) |
| Conductor Cross Section(mm2) |
| AWG size(AWG) |
| Number Of Cores(Core) |
| Logarithm |
| Finished outer diameter(mm) |
| Rated Voltage |
| Shield |
| Properties |
| Representative Standard |
| Sheath (outer coating) color |
| Grounding Wire |
| Sheath (outer coating) material |
| Insulation body materials |
| Drain Wire |
| Wire Standard |
| Brand | TACHIDENSEN | MISUMI | TACHIDENSEN | BANDO DENSEN | BANDO DENSEN | MISUMI | KURAMO ELECTRIC | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | KURAMO ELECTRIC | KURAMO ELECTRIC | TAIYO CABLETEC | TAIYO CABLETEC | TAIYO CABLETEC | TAIYO CABLETEC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Product Series | Cable for factory automation electronic equipment wiring, KVC-36SB Series, shielded | Cable for electronic equipment wiring CM/2464-1061/IIA LF Series (shielded and non-shielded) | Wiring cable for electronic equipment CM/2464-1007/IIA LF Series (shielded and non-shielded) | |||||||||||||||||||||
| Days to Ship | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 7 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 5 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 5 Day(s) or more | 10 Day(s) or more | 10 Day(s) or more | 10 Day(s) or more | 12 Day(s) or more | 10 Day(s) or more | 12 Day(s) or more |
| Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
| Overall Length(m) | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 100 | 1 ~ 49 | 100 | 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 100 | 100 | 1 ~ 49 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 |
| Specified Length(m) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| Conductor Cross Section(mm2) | 0.22 ~ 0.34 | 0.2 ~ 0.5 | 0.3 | - | - | 0.2 ~ 0.5 | 0.5 | 0.2 ~ 0.5 | 0.2 | 0.08 | 0.2 | 0.3 | 0.2 ~ 0.3 | 0.08 | 0.08 | 0.2 | 0.08 | 0.08 | 0.2 ~ 0.3 | 0.2 ~ 0.3 | 0.3 | 0.3 | 0.0804 ~ 0.204 | 0.324 |
| AWG size(AWG) | 22 ~ 24 | 21 ~ 25 | 22 | 20 ~ 26 | 20 ~ 26 | 21 ~ 25 | 20 | 21 ~ 25 | 25 | 28 | 24 | 22 | 23 ~ 25 | 28 | 28 | 25 | 28 | 28 | 23 ~ 25 | 23 ~ 25 | 22 ~ 26 | 22 ~ 26 | 24 ~ 28 | 22 |
| Number Of Cores(Core) | 16 | - | 16 | - | - | - | 16 | - | - | - | - | - | - | - | - | - | - | - | 16 | 16 | 16 | 16 | 16 | 16 |
| Logarithm | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P | 8P |
| Finished outer diameter(mm) | 8.8 ~ 9.9 | 7.2 ~ 9.9 | 9.6 | 7.4 ~ 11.5 | 8 ~ 12.1 | 7.7 ~ 10 | 11 | 8.1 ~ 10.6 | 9.7 | 8.2 ~ 8.3 | 9 | 11.1 | 7.6 ~ 8.8 | 8.2 | 8.3 | 9.8 | 5.5 | 5.5 | 8.2 ~ 10 | 7.7 ~ 9.5 | 7.8 ~ 11.1 | 7.2 ~ 10.4 | 7.5 ~ 9.1 | 12.4 |
| Rated Voltage | 300V | 300V | Other | 300V | 300V | 300V | For Low Current Circuits | For Low Current Circuits | 300V | 300V | 300V | For Low Current Circuits | For Low Current Circuits | 300V | 300V | 300V | For Low Current Circuits | For Low Current Circuits | 150V | 150V | 30V | 30V | 300V | 300V |
| Shield | NA | NA | Available | NA | Available | Available | Available | Available | Available | Available | Available | Available | NA | Available | Available | Available | Available | Available | Available | NA | Available | NA | Available / NA | Available |
| Properties | Oil Resistance / Heat-Resistance | Oil Resistance | Oil Resistance / Heat-Resistance | Heat-Resistance | Heat-Resistance | Oil Resistance | Oil Resistance | Oil Resistance | - | - | Oil Resistance | Oil Resistance | Oil Resistance | - | - | - | - | - | Oil Resistance / Heat-Resistance | Oil Resistance | Oil Resistance / Heat-Resistance | Oil Resistance / Heat-Resistance | Oil Resistance / Heat-Resistance | Oil Resistance / Heat-Resistance |
| Representative Standard | UL / CSA(c-UL) | UL | UL / CSA(c-UL) | UL / CSA(c-UL) | UL / CSA(c-UL) | UL | UL / CSA(c-UL) | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | UL | CSA(c-UL) / UL RECOGNIZED | CSA(c-UL) / UL RECOGNIZED | CSA(c-UL) / UL RECOGNIZED | CSA(c-UL) / UL RECOGNIZED | CSA(c-UL) / UL LISTED | CSA(c-UL) / UL LISTED |
| Sheath (outer coating) color | Black | Blue | Gray | Black | Black | Blue | Black | Blue | Blue | Blue | Black | Blue | Blue | Blue | Blue | Blue | Blue | Blue | Black | Black | Black | Black | Black | Black |
| Grounding Wire | NA | - | Other | - | - | - | Other | - | - | - | - | - | - | - | - | - | - | - | NA | - | - | NA | NA | NA |
| Sheath (outer coating) material | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) |
| Insulation body materials | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | Polyethylene-Based | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | Polyethylene-Based | Polyethylene-Based | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) |
| Drain Wire | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Available | - | N/A | - |
| Wire Standard | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy