(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • [Notice] Japan & China Golden Week holidays will start from 29 April to 6 May 2026. Kindly expect longer response from suppliers and possible delivery delay due to high volume of shipments after holiday. Early order placement is recommended. More details
  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

Control/Instrumentation Cables(Shield:NA Page2)

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 2 Day(s) or Less
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • 10 Day(s) or Less
  • 11 Day(s) or Less
  • 12 Day(s) or Less
Brand
Product Series
Days to Ship
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials
Drain Wire
Wire Standard

    Compensating Lead Wire - Thermocouple R Type - RCB-2-H-GGBF Series - New Color Type

      Compensating Cable, Thermocouple R Type, RX-H-GGBF Series

        Compensating Cable, Thermocouple T Type, TX-1-G-VVF Series, New Color Type

          Compensating Cable, Thermocouple T Type, TX-G-VVF Series

            Compensating Conductor, Vinyl Flat Type Series

              Sheathed Thermocouple Wire, Vinyl Flat Type Series

                Sheathed Thermocouple Wire, FEP Flat Type Series

                  Cable for electronic equipment wiring CM/2464-1061/IIA LF Series (shielded and non-shielded)

                    Wiring cable for electronic equipment CM/2464-1007/IIA LF Series (shielded and non-shielded)

                    Brand

                    FUKUDEN

                    FUKUDEN

                    FUKUDEN

                    FUKUDEN

                    DAIKOUDENKOUSYA

                    DAIKOUDENKOUSYA

                    DAIKOUDENKOUSYA

                    TAIYO CABLETEC

                    TAIYO CABLETEC

                    Product Series

                    Compensating Lead Wire - Thermocouple R Type - RCB-2-H-GGBF Series - New Color Type

                    Compensating Cable, Thermocouple R Type, RX-H-GGBF Series

                    Compensating Cable, Thermocouple T Type, TX-1-G-VVF Series, New Color Type

                    Compensating Cable, Thermocouple T Type, TX-G-VVF Series

                    Compensating Conductor, Vinyl Flat Type Series

                    Sheathed Thermocouple Wire, Vinyl Flat Type Series

                    Sheathed Thermocouple Wire, FEP Flat Type Series

                    Cable for electronic equipment wiring CM/2464-1061/IIA LF Series (shielded and non-shielded)

                    Wiring cable for electronic equipment CM/2464-1007/IIA LF Series (shielded and non-shielded)

                    Days to Ship 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 8 Day(s) or more 10 Day(s) or more 10 Day(s) or more
                    Overall Length(m)10 ~ 10010 ~ 10010 ~ 10010 ~ 10020 ~ 10010 ~ 10020 ~ 1001 ~ 1001 ~ 100
                    Specified Length(m)---------
                    Conductor Cross Section(mm2)1.250.5 ~ 1.251.250.5 ~ 1.250.5--0.128 ~ 0.2040.324 ~ 1.3
                    AWG size(AWG)-------24 ~ 2616 ~ 22
                    Number Of Cores(Core)22222222 ~ 602 ~ 30
                    Logarithm11111111P ~ 30P-
                    Finished outer diameter(mm)3.0x5.12.1x3.7 ~ 3.0x5.14.6x7.12.8x4.6 ~ 4.6x7.12.6x4.21.2x1.8 ~ 2.6x4.00.8x1.2 ~ 1.6x2.83.9 ~ 13.55.5 ~ 16.8
                    Rated Voltage-------300V300V
                    ShieldNANANANANANANANANA
                    PropertiesHeat-ResistanceHeat-Resistance----Oil Resistance / Heat-Resistance / Cold Resistance / Chemical ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-Resistance
                    Representative Standard-------CSA(c-UL) / UL LISTEDCSA(c-UL) / UL LISTED
                    Sheath (outer coating) colorOrangeBlackBrownBrown-Brown / Yellow / BlueBrown / Yellow / BlueBlackBlack
                    Grounding WireNANANANANANANANAColored YG (yellow/green) / NA
                    Sheath (outer coating) materialOtherOtherPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)-PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)
                    Insulation body materialsOtherOtherPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)Fluorine-BasedPVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)
                    Drain Wire-------N/A-
                    Wire Standard---------

                    Loading...

                    Related Categories to Control/Instrumentation Cables