Control/Instrumentation Cables(Insulation body materials:Polyethylene-Based)

Control and instrumentation cables are used for device controls and signal transmissions to and from terminal devices. Control cables are mainly used to control devices in plants and factories. For this reason, insulated vinyl sheath cables with PVC and polyethylene insulation are usually used for their highly flame retardant properties and excellent oil resistance, weather resistance and water resistance. Instrumentation cables are used in a wide range of applications including transmitting computer signals, electronic controls for industrial equipment, etc. Insulated vinyl sheath cables with polyethylene insulators are often used for their capacitance and noise reduction characteristics. The cables are selected for length and number of pairs, but other specific properties should also be considered, such as abrasion resistance and chemical resistance.
Days to Ship
  • All
  • 2 Day(s) or Less
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 6 Day(s) or Less
  • 7 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • 10 Day(s) or Less
  • 11 Day(s) or Less
  • 12 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Specifications
Overall Length(m)
Specified Length(m)
Conductor Cross Section(mm2)
AWG size(AWG)
Number Of Cores(Core)
Logarithm
Finished outer diameter(mm)
Rated Voltage
Shield
Properties
Representative Standard
Sheath (outer coating) color
Grounding Wire
Sheath (outer coating) material
Insulation body materials
Drain Wire
Wire Standard

    Instrumentation Cable, FKEV-SB

      Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

        CL2/2464-3599-DS LF

          NA20276H Cross-Linked Polyethylene UL-Supported

            KFPEV-SB Cable for Light Electrical Appliances and Instrumentation

              NA20276HB Cross-Linked Polyethylene UL with Shield

                Wiring cable for electronic devices HK-SB/20276 XL LF

                  Wiring cable for electronic equipment HK/20276 XL LF

                  Brand

                  FUJIDENSEN

                  NIHONDENSEN

                  TAIYO CABLETEC

                  MISUMI

                  FUJIELECTRICCAB

                  MISUMI

                  TAIYO CABLETEC

                  TAIYO CABLETEC

                  Product Series

                  Instrumentation Cable, FKEV-SB

                  Polyethylene Insulation Vinyl Sheath Instrumentation Cable J-KNPEV-SB

                  CL2/2464-3599-DS LF

                  NA20276H Cross-Linked Polyethylene UL-Supported

                  KFPEV-SB Cable for Light Electrical Appliances and Instrumentation

                  NA20276HB Cross-Linked Polyethylene UL with Shield

                  Wiring cable for electronic devices HK-SB/20276 XL LF

                  Wiring cable for electronic equipment HK/20276 XL LF

                  Days to Ship 4 Day(s) or more 4 Day(s) or more 4 Day(s) or more 4 Day(s) or more 9 Day(s) or more 4 Day(s) or more 10 Day(s) or more 10 Day(s) or more
                  Specifications
                        • VW-1
                        • ULAWM
                        • Oil-Resistant
                        • Strand Wire
                        • Small Diameter
                        • 30 V
                          • VW-1
                          • ULAWM
                          • Oil-Resistant
                          • Strand Wire
                          • Single Shield
                          • Twisted Pair
                          • 30 V
                              Overall Length(m)1 ~ 1001 ~ 1001 ~ 100100-1001 ~ 1001 ~ 100
                              Specified Length(m)----100---
                              Conductor Cross Section(mm2)0.3 ~ 1.250.2 ~ 20.204 ~ 0.8230.12 ~ 0.30.5 ~ 1.250.12 ~ 0.30.30.3
                              AWG size(AWG)-14 ~ 2418 ~ 2422 ~ 2616 ~ 2022 ~ 2622 ~ 2622 ~ 26
                              Number Of Cores(Core)2 ~ 202 ~ 60-2 ~ 202 ~ 6032 ~ 502 ~ 50
                              Logarithm1 ~ 101P ~ 30P1P ~ 5P-1P ~ 30P1P ~ 8P2P ~ 25P1P ~ 25P
                              Finished outer diameter(mm)5 ~ 205.5 ~ 285.1 ~ 143.7 ~ 87 ~ 32.54.3 ~ 11.14.3 ~ 17.73.7 ~ 16.9
                              Rated VoltageOther31 to 100 VFor Low Current CircuitsFor Low Current Circuits-For Low Current Circuits30V30V
                              ShieldAvailableAvailableAvailableNAAvailableAvailableAvailableNA
                              PropertiesOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-ResistanceOil Resistance-Oil ResistanceOil Resistance / Heat-ResistanceOil Resistance / Heat-Resistance
                              Representative Standard--UL / CSA(c-UL)UL-ULCSA(c-UL) / UL RECOGNIZEDCSA(c-UL) / UL RECOGNIZED
                              Sheath (outer coating) colorGrayBlackBlackBlueBlackBlueBlackBlack
                              Grounding WireOtherNANA-NA--NA
                              Sheath (outer coating) materialPVC (Polyvinyl Chloride)-PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)PVC (Polyvinyl Chloride)
                              Insulation body materialsPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-BasedPolyethylene-Based
                              Drain Wire------Available-
                              Wire Standard--------