| Days to Ship |
|
|---|

UL Listed Unshielded Instrumentation Cable
TACHIDENSEN
UL compliant unshielded instrumentation cable U-TKVV series
[Features]
· A UL listing (ULPLCC), UL recognized (ULAWM), cUL (CSAAWM) multi-standard cable.
· Cable compatible with NFPA79.
· Superior heat resistance, oil resistance, and flexibility.
· A wide range of products are available, distinguished by different conductor sizes (AWG 24-AWG 16), number of center strands, and presence or absence of braided shield.
· Because a twister pair type is set at a different pitch than adjacent pairs, crosstalk noise can be reduced.
· Braid shielded type cable has a drain wire of the same size as the conductor.
· Shield connection is easy.
· Conductor size and number of core wires (pairs) are printed on cable surface.
· Makes cable identification easy.
| Standard Price: | MYR 22.92- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

CVV-S Vinyl Insulation Vinyl Sheath Cable
FUJIKURADAIA
Made by Fujikura Dia Cable Ltd. Shielding is provided to prevent induction for power wires, AC drive railway and such.
[Features]
▪ JIS certified product (JIS mark is displayed).
· Control cables are used in control circuits in transformer substations and in all varieties of plants. 1.25 mm, and 2 mm cables are the most commonly used sizes.
· While the number of wire cores is generally about 30, twisted pairs of wire cores have recently been used for instrumentation.
▪ CVV uses lead-free PVC.
| Standard Price: | MYR 113.10- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

For K TYPE Thermocouple Normal Grade / Precision Grade / Heat-Resistant Flexible Precision Grade
MISUMI
K Thermocouples Lead Wire Mounting / Movable Cable
| Standard Price: | MYR 21.12- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
300 V cable for fixed signals, CL3/ULAWM2464 standard compliant. A sheath with excellent oil resistance and flexibility is used.
| Standard Price: | MYR 14.16- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NASE Series Wire Core ID for Sensor
MISUMI
ULAWM standard compliant cable for UL standard control equipment sensors, with excellent oil resistance and heat resistance. Three types are available: for fixed general wiring, for sputtering, and for movable use.
| Standard Price: | MYR 9.31- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

Shielded Twisted Pair Multi-Core Cable, SPMC Series
KANEKO CORD
A shielded twisted pair cable that uses 0.08 mm fine annealed copper wire for high flexibility.
[Features]
· The conductor uses 30/0.08 fine annealed copper wire.
· Achieves high level of flexibility.
· Uses a twisted pair configuration that provides favorable noise resistance and signal characteristics.
· Is shielded and is effective as an EMC measure.
| Standard Price: | MYR 24.40- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MVVS 100 V or Less with Shield
MISUMI
Value Series For Weak-Current Circuit General-purpose Signals Cable
| Days to Ship: | 4 Day(s) or more |
|---|

CVV Vinyl Insulation Vinyl Sheath Cable
FUJIKURADAIA
Fujikura Dia Cable for control systems in factories, electricity stations and substations, etc., with vinyl insulation and sheath.
[Features]
• JIS certified product (JIS mark is present)
• Control cables are found in control circuits in electricity stations and substations, as well as a variety of other plants. 1.25 mm² and 2 mm² cables are the most commonly used.
• About 30 cores is common, and recently instrumentation is going to twisted pairs.
▪ CVV uses lead-free PVC.
| Standard Price: | MYR 83.17- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
300 V cable for fixed signals, ULAWM2517 standard compliant, with excellent oil resistance.
| Standard Price: | MYR 9.45- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

Twisted Pair Instrumentation Cable
TACHIDENSEN
Twisted pair Instrumentation cable TKVVBS series
[Features]
· Superior heat resistance, oil resistance, and flexibility.
· Twisted layer types and twisted pair types are available.
· Because a twisted pair type is set at a different pitch to adjacent pairs, crosstalk noise can be reduced.
· A braided shield is provided as a noise countermeasure.
· Shield wiring work can be performed easily thanks to a drain wire of the same size as the conductor.
| Standard Price: | MYR 27.05- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

BIO Highly Flame Retardant NEC Standard Cable (Non-Shield)
BANDO DENSEN
Suitable for wiring of electrical and electronic equipment subject to UL (AWM)/cUL (CSA)/NFPA (70/79) standards (unshielded type).
[Features]
· Uses UL (AWM), cUL (CSA), and NFPA (70/79) standards.
· Flame retardancy is UL: VW-1, CL2, CL3, cUL (CSA): FT1/FT2..
· High-density braid shielding.
| Standard Price: | MYR 11.23- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
150 V Cable for UL-AWM Standard Signals
| Standard Price: | MYR 533.55- |
|---|---|
| Days to Ship: | 2 Day(s) |

TAIYO CABLETEC
UL VW-1 and cUL FT1 compliant flame retardant cable
[Features]
· UL VW-1 and cUL FT1 (category QPTZ, AVLV2, AVLV7) compliant flame retardancy.
▪ Passed UL vertical tray flame retardancy test.
· Uses an oil, heat, and flame resistant flexible vinyl sheath material.
· Also usable as tray cable.
· RS485, RS422, and RS232C compatible cable.
· Certified to listing standard CL2 and suitable for NFPA70.
| Standard Price: | MYR 88.89- |
|---|---|
| Days to Ship: | 13 Day(s) or more |

VVC Highly Flame-Retardant NEC Standard Cable (Unshielded)
BANDO DENSEN
Suitable for wiring of electrical and electronic equipment subject to the UL (AWM), NFPA (70, 79) standards (unshielded type).
[Features]
▪ Approved by UL (AWM), NFPA (70, 79) standards.
· Flame retardancy UL: VW-1, CL2, CL3.
· High-density braid shielding.
| Standard Price: | MYR 10.81- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

BIOS Highly Flame Retardant NEC Standard Cable (Shielded)
BANDO DENSEN
High density braid shielding suitable for wiring of electrical and electronic equipment subject to UL (AWM)/cUL (CSA)/NFPA (70/79) standards.
[Features]
· Uses UL (AWM), cUL (CSA), and NFPA (70/79) standards.
· Flame retardancy is UL: VW-1, CL2, CL3, cUL (CSA): FT1/FT2..
· High-density braid shielding.
| Standard Price: | MYR 27.29- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NA3VCSB UL Standard with Shield
MISUMI
300 V oil-resistant shielded cable for fixed signals, ULAWM2517 standard compliant.
| Standard Price: | MYR 17.96- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
ULAWM standard compliant shielded composite cable for servo encoders/stepping that can be used for fixed and movable applications.
| Days to Ship: | 4 Day(s) or more |
|---|

KURAMO ELECTRIC
Suitable for wiring of control circuit for machine tools
[Features]
· UL/cUL standard cable.
· Noise resistance.
· Flexibility.
· Oil resistance.
| Standard Price: | MYR 31.31- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

Twisted Pair Multi-Core Cable PMC Series
KANEKO CORD
A twisted pair cable that uses 0.08 mm fine annealed copper wire for high flexibility.
[Features]
· The conductor uses 30/0.08 fine annealed copper wire.
· Achieves high level of flexibility.
· Uses a twisted pair configuration that provides favorable noise resistance and signal characteristics.
| Standard Price: | MYR 18.33- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

Compensating Cable, Thermocouple J Type, JX-1-G-VVF Series, New Color Type
FUKUDEN
A compensating cable for type K thermocouples - Precision grade, compatible with new JIS types, and with general vinyl used for both insulation and sheathing. An unshielded flat compensating cable. A standard model featuring moisture and water-proof properties.
[Features]
• A compensating cable with regular vinyl insulation and jacket for unshielded thermocouples.
· A standard model featuring moisture and water-proof properties.
| Standard Price: | MYR 250.20- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

Compensating Cable, Thermocouple K Type, KX-GS-VVR Series
FUKUDEN
[Features]
· Compensating cable with general vinyl insulation and jacket for shielded thermocouples (flat shape).
Contains round type wires with electrostatic shielding, and moisture and water proofing.
| Standard Price: | MYR 410.81- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

Compensating Cable, Thermocouple K Type, VX-G-VVR Series
FUKUDEN
[Features]
• A round shielded compensating cable with general vinyl insulation and jacket for thermocouples.
• A round type that is moisture and water-proof.
| Standard Price: | MYR 258.92- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

Compensating Conductor, Vinyl Flat Type Shield Series
DAIKOUDENKOUSYA
Flame retardant 105℃ heat resistant vinyl coating, flat, slim type
| Standard Price: | MYR 307.38- |
|---|---|
| Days to Ship: | 8 Day(s) or more |
| Standard Price: | MYR 41.51- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NAVCSB UL Standard with Shield
MISUMI
150 V fixed signal shielded cable for small diameter, ULAWM2576/ULAWM2095 standard compliant, with excellent oil resistance.
| Standard Price: | MYR 17.84- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NAKVVSB 100 V or less with Shield
MISUMI
General-purpose shielded signal cable for low-current circuits with excellent oil resistance and noise resistance.
| Standard Price: | MYR 9.96- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NASWS UL Each Pair Triple-Shielded Aluminum Foil Tape
MISUMI
300 V cable, ULAWM2464 standard compliant, with excellent noise resistance. The triple shielded cable consists of aluminum foil tape, braided shield, and each pair of shields, to provide excellent noise prevention. Each pair is shielded (drain wire), so it is easy to perform machining in terminal works such as earth terminal connection.
| Standard Price: | MYR 1,320.77- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

300 V Shielded Cable for Signals
MISUMI
Shielded signal cable with fusion splicing for IDC connectors that uses 300 V cable compliant with the ULAWM2464 standard.
| Days to Ship: | 5 Day(s) or more |
|---|

Twisted Layer Instrumentation Cable
TACHIDENSEN
Twisted layer instrumentation cable, TKVVBS series
[Features]
· Has superior heat resistance, oil resistance, and flexibility.
· Twisted layer types and twisted pair types available.
· Because the twisted pair type is set at a different pitch than adjacent pairs, crosstalk noise can be reduced.
· Braided shield provided as noise countermeasure.
· Shield wiring work can also be performed easily because a drain wire the same size as the conductor is provided.
| Standard Price: | MYR 23.87- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

VSVC Highly Flame-Retardant NEC Standard Cable (Shielded)
BANDO DENSEN
Suitable for wiring of electrical and electronic equipment subject to UL (AWM)/NFPA (70/79) standards.
[Features]
· Uses UL (AWM) and NFPA (70/79) standards.
· Flame retardancy is UL: VW-1, CL2, CL3.
· High-density braid shielding.
| Standard Price: | MYR 19.66- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

Compensating Lead Wire - Thermocouple T Type - T-HVVF Series
FUKUDEN
[Features]
· A shielded, non-flat coated, thermocoupled wire provided with a heat-resistant vinyl insulation, and a heat-resistant vinyl jacket.
· Standard model that is moisture proof, waterproof, and heat resistant for continuous use at 80°C.
| Standard Price: | MYR 119.60- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

Compensating Cable, Thermocouple K Type, KX-GS-SHVVF-BT Series
FUKUDEN
[Features]
A compensating cable for type K thermocouples - precision grade, special heat resistant vinyl (heat resistant to 105°C) is used for both insulation and sheathing. A flat compensating cable with braided shielding. Standard model with moisture and water-proof properties.
| Standard Price: | MYR 286.28- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

Compensating Lead Wire - Thermocouple K Type - KX-GS-VVR-BA Series
FUKUDEN
[Features]
· Round type compensating conductor for shielded thermocouple with regular vinyl insulation and regular vinyl jacket.
·A round type that is moisture-proof and waterproof, and has an electrostatic shielding effect.
| Standard Price: | MYR 512.57- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

Compensating Lead Wire - Thermocouple K Type - VX-G-VVF Series
FUKUDEN
[Features]
· Flat compensating conductor for non-shielded thermocouple with regular vinyl insulation and regular vinyl jacket.
· Standard model that is moisture proof and waterproof.
| Standard Price: | MYR 155.24- |
|---|---|
| Days to Ship: | 6 Day(s) or more |

Compensating Cable, Thermocouple R Type, RX-G-VVF Series
FUKUDEN
[Features]
· A flat, unshielded, compensating cable with general vinyl insulation and jacket for thermocouples.
· A standard model that is moisture and water-proof.
| Standard Price: | MYR 149.84- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

SSCL3SB, UL-Listed (CL3) Support With Shield
MISUMI
300 V shielded cable for fixed signals, CL3/ULAWM2464 standard compliant. A sheath with excellent oil resistance and flexibility is used.
| Standard Price: | MYR 647.26- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
150 V fixed signal cable for small diameter, ULAWM2576/ULAWM2095 standard compliant, with excellent oil resistance.
| Standard Price: | MYR 8.00- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

MISUMI
300 V cable, ULAWM2464 standard compliant. A small diameter type with a braided shield for EMI shielding.
| Standard Price: | MYR 19.67- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NA28WSB UL 300 V 2-Shielded Cable
MISUMI
300 V cable, ULAWM2464 standard compliant. Excellent noise prevention effect is achieved by using a double shield consisting of aluminum foil tape and braided shield.
| Standard Price: | MYR 24.27- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NANB UL Each Pair Triple-Shielded Magnetic Foil Tape
MISUMI
300 V cable, ULAWM2464 standard compliant, with excellent noise resistance. The triple shield consists of magnetic foil tape, braided shield, and each pair of shields, to provide excellent noise prevention. Each pair is shielded (drain wire), so it is easy to perform machining in terminal works such as earth terminal connection.
| Standard Price: | MYR 6,420.17- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

NA20276 UL Standard with Shield AWG28
MISUMI
30 V single shielded cable, ULAWM20276 standard compliant, with excellent oil resistance and noise resistance. Only AWG size 28 is available, and a braided shield is applied for EMI shielding.
| Standard Price: | MYR 1,268.29- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

30 V Shielded Cable for Signals
MISUMI
Shielded signal cable with fusion splicing for IDC connectors that uses 30 V cable compliant with the ULAWM20276 standard.
| Days to Ship: | 5 Day(s) or more |
|---|

SHINAGAWA
[Applications]
· A flexible type fixing cord that is UL/CSA rated and used as a power supply, etc., for electrical equipment.
| Standard Price: | MYR 52.27- |
|---|---|
| Days to Ship: | 10 Day(s) or more |

Cable for factory automation electronic equipment wiring, KVC-36SB Series, shielded
KURAMO ELECTRIC
[Features]
· Noise resistance
· Flexibility
· Oil resistance
· UL and cUL standard cable
[Applications]
· Wiring to control circuits of machine tools
· Wiring in oil environments
· Wiring for locations requiring noise resistance
| Standard Price: | MYR 30.78- |
|---|---|
| Days to Ship: | 10 Day(s) or more |

KURAMO ELECTRIC
[Features]
·Flexibility.
·Oil resistance.
·UL/cUL standard cable.
[Applications]
·Wiring to the control circuit of the machine tool.
·Wiring in an oily environment.
·Please refer to the following for shielded products.
| Standard Price: | MYR 28.44- |
|---|---|
| Days to Ship: | 10 Day(s) or more |
| Brand |
|---|
| Product Series |
| Days to Ship |
| Specifications |
| Overall Length(m) |
| Specified Length(m) |
| Conductor Cross Section(mm2) |
| AWG size(AWG) |
| Number Of Cores(Core) |
| Logarithm |
| Finished outer diameter(mm) |
| Rated Voltage |
| Shield |
| Properties |
| Representative Standard |
| Sheath (outer coating) color |
| Grounding Wire |
| Sheath (outer coating) material |
| Insulation body materials |
| Drain Wire |
| Wire Standard |
| Brand | TACHIDENSEN | FUJIKURADAIA | MISUMI | MISUMI | MISUMI | KANEKO CORD | MISUMI | FUJIKURADAIA | MISUMI | TACHIDENSEN | BANDO DENSEN | MISUMI | TAIYO CABLETEC | BANDO DENSEN | BANDO DENSEN | MISUMI | MISUMI | KURAMO ELECTRIC | KANEKO CORD | FUKUDEN | FUKUDEN | FUKUDEN | DAIKOUDENKOUSYA | HITACHI CABLE | MISUMI | MISUMI | MISUMI | MISUMI | TACHIDENSEN | BANDO DENSEN | FUKUDEN | FUKUDEN | FUKUDEN | FUKUDEN | FUKUDEN | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | MISUMI | SHINAGAWA | KURAMO ELECTRIC | KURAMO ELECTRIC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Product Series | For K TYPE Thermocouple Normal Grade / Precision Grade / Heat-Resistant Flexible Precision Grade | Compensating Cable, Thermocouple J Type, JX-1-G-VVF Series, New Color Type | Compensating Lead Wire - Thermocouple T Type - T-HVVF Series | Compensating Cable, Thermocouple K Type, KX-GS-SHVVF-BT Series | Compensating Lead Wire - Thermocouple K Type - KX-GS-VVR-BA Series | Compensating Lead Wire - Thermocouple K Type - VX-G-VVF Series | Cable for factory automation electronic equipment wiring, KVC-36SB Series, shielded | ||||||||||||||||||||||||||||||||||||||
| Days to Ship | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 2 Day(s) | 13 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 8 Day(s) or more | 8 Day(s) or more | 8 Day(s) or more | 8 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 5 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 8 Day(s) or more | 8 Day(s) or more | 8 Day(s) or more | 6 Day(s) or more | 8 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 5 Day(s) or more | 10 Day(s) or more | 10 Day(s) or more | 10 Day(s) or more |
| Specifications |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||||||||||
| Overall Length(m) | 1 ~ 100 | 10 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 99 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 10 ~ 100 | 10 ~ 100 | 10 ~ 100 | 20 ~ 100 | 1 ~ 200 | 1 ~ 100 | 1 ~ 100 | 100 | 1 ~ 49 | 1 ~ 100 | 1 ~ 100 | 10 ~ 100 | 10 ~ 100 | 10 ~ 100 | 10 ~ 100 | 10 ~ 100 | 100 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 | 100 | 100 | 1 ~ 49 | 1 ~ 100 | 1 ~ 100 | 1 ~ 100 |
| Specified Length(m) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| Conductor Cross Section(mm2) | 0.22 ~ 0.54 | 1.25 ~ 2 | 0.5 ~ 1.25 | 0.2 ~ 0.5 | 0.08 ~ 0.5 | 0.15 | 0.3 ~ 2 | 1.25 ~ 3.5 | 0.2 ~ 1.25 | 0.2 ~ 0.5 | - | 0.2 | 0.204 ~ 1.3 | - | - | 0.2 ~ 1.25 | 0.12 ~ 0.2 | 0.5 | 0.15 | 1.25 | 1.25 | 1.25 | 0.5 | 0.12 ~ 0.2 | 0.12 ~ 0.5 | 0.2 ~ 0.5 | 0.2 | 0.08 | 0.2 ~ 0.3 | - | 0.08 ~ 0.33 | 0.5 | 1.25 | 0.5 ~ 2 | 0.5 ~ 1.25 | 0.2 ~ 0.5 | 0.12 ~ 0.5 | 0.08 | 0.08 | 0.2 | 0.08 | 0.08 | 0.75 | 0.2 ~ 0.5 | 0.2 ~ 0.5 |
| AWG size(AWG) | 20 ~ 24 | 14 ~ 16 | 16 ~ 20 | 20 ~ 24 | 20 ~ 28 | 26 | 14 ~ 22 | 12 ~ 16 | 16 ~ 25 | 20 ~ 24 | 16 ~ 26 | 25 | 16 ~ 24 | 20 ~ 24 | 16 ~ 26 | 16 ~ 25 | 24 ~ 26 | 20 | 26 | - | - | - | - | 24 ~ 26 | 21 ~ 27 | 21 ~ 25 | 25 | 28 | 22 ~ 24 | 20 ~ 24 | - | - | - | - | - | 20 ~ 24 | 21 ~ 27 | 28 | 28 | 25 | 28 | 28 | - | 20 ~ 25 | 20 ~ 25 |
| Number Of Cores(Core) | 2 ~ 50 | 2 ~ 10 | - | 2 ~ 34 | 2 ~ 4 | 4 ~ 50 | 3 ~ 16 | 2 ~ 30 | 2 ~ 12 | 2 ~ 50 | 2 ~ 10 | - | 4 ~ 30 | 2 ~ 14 | 2 ~ 10 | 2 ~ 12 | 4 | 2 ~ 30 | 8 ~ 36 | 2 | 2 | 2 | 2 | 10 ~ 50 | - | - | - | - | 2 ~ 40 | 2 ~ 40 | 2 | 2 | 2 | 2 | 2 | - | - | - | - | - | - | - | 3 | 2 ~ 64 | 2 ~ 64 |
| Logarithm | 1P ~ 25P | - | - | - | - | 2P ~ 25P | - | - | 1P ~ 25P | 1P ~ 25P | 1P ~ 20P | 1P ~ 2P | 2P ~ 15P | - | 1P ~ 25P | 1P ~ 32P | 2 | 1P ~ 15P | 4P ~ 18P | 1 | 1 | 1 | 1 | 5P ~ 25P | 1P ~ 20P | 1P ~ 20P | 1P ~ 13P | 3P ~ 32P | - | - | 1 | 1 | 1 | 1 | 1 | 1P ~ 8P | 1P ~ 20P | 2P ~ 32P | 1P ~ 20P | 5P ~ 13P | 5P ~ 50P | 5P ~ 25P | - | 1P ~ 32P | 1P ~ 32P |
| Finished outer diameter(mm) | 4 ~ 15 | 10.5 ~ 16 | - | 4.1 ~ 11.2 | 2.8 ~ 6 | 5.5 ~ 11.8 | 5.2 ~ 8.8 | 9.4 ~ 26 | 3.9 ~ 14.1 | 4.6 ~ 15.9 | 4.1 ~ 17.6 | 3.1 ~ 5.2 | 5.1 ~ 18.9 | 4.9 ~ 8.9 | 4.7 ~ 18.3 | 4.4 ~ 14.6 | 5.5 ~ 8.1 | 4.8 ~ 14 | 5.8 ~ 10.6 | 4.6x7.1 | 7.5 | 7.5 | 3.8x5.7 | - | 3.7 ~ 14.2 | 4.6 ~ 16.2 | 4.5 ~ 11.7 | 6.3 ~ 14.1 | 4.6 ~ 11.6 | 5.5 ~ 13.7 | 1.0x1.6 ~ 2.5x3.9 | 3.8x5.7 | 7.8 | 2.8x4.6 ~ 5.0x8.0 | 2.8x4.6 ~ 4.6x7.1 | 4.7 ~ 9.6 | 2.9 ~ 15.3 | 6 ~ 14.1 | 4.5 ~ 11.7 | 8.5 ~ 11.8 | 5.1 ~ 10.4 | 5.1 ~ 8.1 | 6.35 | 3.9 ~ 18 | 3.1 ~ 16.5 |
| Rated Voltage | 300V | 600V | - | 300V | 300V / For Low Current Circuits | For High Voltages | For Low Current Circuits | 600V | 300V | Other | 300V | For Low Current Circuits | 300V | 300V | 300V | 300V | 300V / For Low Current Circuits | For Low Current Circuits | For High Voltages | - | - | - | - | 300V | For Low Current Circuits | For Low Current Circuits | 300V | 300V | Other | 300V | - | - | - | - | - | 300V | For Low Current Circuits | 300V | 300V | 300V | For Low Current Circuits | For Low Current Circuits | 300V | 300V / 150V | 300V / 150V |
| Shield | NA | Available | NA | NA | NA | Available | Available | NA | NA | Available | NA | NA | Available | NA | Available | Available | Available | Available | NA | NA | NA | NA | Available | Available | Available | Available | Available | Available | Available | Available | NA | Available | Available | NA | NA | Available | NA | Available | Available | Available | Available | Available | NA | Available | NA |
| Properties | Oil Resistance / Heat-Resistance | - | - | Oil Resistance | Oil Resistance / Heat-Resistance | - | - | - | Oil Resistance | Oil Resistance / Heat-Resistance | Oil Resistance / Heat-Resistance | Oil Resistance | Oil Resistance / Heat-Resistance | Heat-Resistance | Oil Resistance / Heat-Resistance | Oil Resistance | - | Oil Resistance | - | - | - | Heat-Resistance / Cold Resistance | - | Heat-Resistance | Oil Resistance | Oil Resistance | - | - | Oil Resistance / Heat-Resistance | Heat-Resistance | Heat-Resistance | Heat-Resistance | - | - | - | Oil Resistance | Oil Resistance | - | - | - | - | - | - | Oil Resistance / Heat-Resistance | Oil Resistance |
| Representative Standard | UL / CSA(c-UL) | - | - | UL | UL | - | - | - | UL | UL / CSA(c-UL) | UL / CSA(c-UL) | UL / CSA(c-UL) | CSA(c-UL) / UL LISTED | UL | UL / CSA(c-UL) | UL | UL | UL / CSA(c-UL) | - | - | - | - | - | UL | UL | - | UL | UL | UL / CSA(c-UL) | UL | - | - | - | - | - | UL | UL | UL | UL | UL | UL | UL | CSA(c-UL) / UL RECOGNIZED | CSA(c-UL) / UL RECOGNIZED | CSA(c-UL) / UL RECOGNIZED |
| Sheath (outer coating) color | Black | Black | Blue | Black | Blue | Black | Gray | Black | Blue | Gray | Black | Black | Black | Gray | Black | Blue | Blue | Black | Black | Black | Blue | Blue | - | Gray | Blue | Blue | Blue | Blue | Black | Gray | Brown | Blue | Blue | Blue | Black | Black | Blue | Blue | Blue | Blue | Blue | Blue | Black | Black | Black |
| Grounding Wire | NA | NA | - | - | - | NA | - | NA | - | NA / Other | - | - | NA | - | - | - | - | Other | NA | NA | NA | NA | NA | - | - | - | - | - | Other | - | NA | NA | NA | NA | NA | - | - | - | - | - | - | - | NA | NA | - |
| Sheath (outer coating) material | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) |
| Insulation body materials | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) |
| Drain Wire | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
| Wire Standard | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Other | - | - |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy