(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
| Days to Ship |
|
|---|

Sheathed Thermocouple - Thermocouple T Type - T-FFF Series
FUKUDEN
[Features]
K-coated thermocouple, fluororesin (FEP) along with insulation and sheath, flat coated thermocouple. Offers heat resistance, cold resistance, chemical resistance, moisture proof properties and waterproof properties.
| Standard Price: | MYR 217.90- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

Compensating Lead Wire - Thermocouple T Type - T-HVVF Series
FUKUDEN
[Features]
· A shielded, non-flat coated, thermocoupled wire provided with a heat-resistant vinyl insulation, and a heat-resistant vinyl jacket.
· Standard model that is moisture proof, waterproof, and heat resistant for continuous use at 80°C.
| Standard Price: | MYR 119.60- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

Compensating Cable, Thermocouple T Type, TX-1-G-VVF Series, New Color Type
FUKUDEN
[Features]
· A flat, non-shielded compensating cable for thermocouples. Features special heat resistant vinyl insulation and sheathing.
· A standard model that is moisture and waterproof.
| Standard Price: | MYR 250.20- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

Compensating Conduction Wire - Thermocouple T Type- TX-G-VVF-BA Series
FUKUDEN
[Features]
· Flat type compensating conductor for shielded thermocouple with regular vinyl insulation and regular vinyl jacket.
· A general type that is moisture proof and waterproof, and has an electrostatic shielding effect.
| Standard Price: | MYR 210.31- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

Compensating Cable, Thermocouple T Type, TX-G-VVF Series
FUKUDEN
[Features]
· A flat, unshielded, compensating cable with general vinyl insulation and jacket for thermocouples.
· A standard model that is moisture and water-proof.
| Standard Price: | MYR 149.84- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

Compensating Conduction Wire - Thermocouple T Type - TX-G-VVR-SA Series
FUKUDEN
[Features]
· Round type compensating conductor for shielded thermocouple with regular vinyl insulation and regular vinyl jacket.
·A round type that is moisture proof and waterproof, and has an electrostatic shielding effect.
| Standard Price: | MYR 328.04- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

Sheathed Thermocouple Wire, Vinyl Flat Type Series
DAIKOUDENKOUSYA
Flame retardant 105ºC heat resistant vinyl coating
| Standard Price: | MYR 161.04- |
|---|---|
| Days to Ship: | 8 Day(s) or more |

Sheathed Thermocouple Wire, FEP Flat Type Series
DAIKOUDENKOUSYA
Heat and cold resistant (-250ºC to +200ºC), chemical resistant
| Standard Price: | MYR 431.70- |
|---|---|
| Days to Ship: | 8 Day(s) or more |
| Brand |
|---|
| Product Series |
| Days to Ship |
| Overall Length(m) |
| Specified Length(m) |
| Conductor Cross Section(mm2) |
| AWG size(AWG) |
| Number Of Cores(Core) |
| Logarithm |
| Finished outer diameter(mm) |
| Rated Voltage |
| Shield |
| Properties |
| Representative Standard |
| Sheath (outer coating) color |
| Grounding Wire |
| Sheath (outer coating) material |
| Insulation body materials |
| Drain Wire |
| Wire Standard |
| Brand | FUKUDEN | FUKUDEN | FUKUDEN | FUKUDEN | FUKUDEN | FUKUDEN | DAIKOUDENKOUSYA | DAIKOUDENKOUSYA |
|---|---|---|---|---|---|---|---|---|
| Product Series | Compensating Lead Wire - Thermocouple T Type - T-HVVF Series | Compensating Cable, Thermocouple T Type, TX-1-G-VVF Series, New Color Type | Compensating Conduction Wire - Thermocouple T Type- TX-G-VVF-BA Series | Compensating Conduction Wire - Thermocouple T Type - TX-G-VVR-SA Series | ||||
| Days to Ship | 8 Day(s) or more | 8 Day(s) or more | 8 Day(s) or more | 8 Day(s) or more | 8 Day(s) or more | 8 Day(s) or more | 8 Day(s) or more | 8 Day(s) or more |
| Overall Length(m) | 10 ~ 100 | 10 ~ 100 | 10 ~ 100 | 10 ~ 100 | 10 ~ 100 | 10 ~ 100 | 20 ~ 100 | 20 ~ 100 |
| Specified Length(m) | - | - | - | - | - | - | - | - |
| Conductor Cross Section(mm2) | 0.03 ~ 0.33 | 0.08 ~ 0.33 | 1.25 | 0.5 ~ 1.25 | 0.5 ~ 1.25 | 1.25 | - | - |
| AWG size(AWG) | - | - | - | - | - | - | - | - |
| Number Of Cores(Core) | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Logarithm | 1 | 1 | 1 | 1 | 1 | 1 ~ 10 | 1 | 1 |
| Finished outer diameter(mm) | 0.9x1.4 ~ 1.8x2.9 | 1.0x1.6 ~ 2.5x3.9 | 4.6x7.1 | 3.4x5.2 ~ 5.2x7.7 | 2.8x4.6 ~ 4.6x7.1 | 7.9 ~ 21 | 1.2x1.8 ~ 2.6x4.0 | 0.8x1.2 ~ 1.6x2.8 |
| Rated Voltage | - | - | - | - | - | - | - | - |
| Shield | NA | NA | NA | Available | NA | Available | NA | NA |
| Properties | - | Heat-Resistance | - | Heat-Resistance / Cold Resistance | - | - | - | Oil Resistance / Heat-Resistance / Cold Resistance / Chemical Resistance |
| Representative Standard | - | - | - | - | - | - | - | - |
| Sheath (outer coating) color | Brown | Brown | Brown | Brown | Brown | Brown | Brown | Brown |
| Grounding Wire | NA | NA | NA | NA | NA | NA | NA | NA |
| Sheath (outer coating) material | Other | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | - |
| Insulation body materials | Other | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | Fluorine-Based |
| Drain Wire | - | - | - | - | - | - | - | - |
| Wire Standard | - | - | - | - | - | - | - | - |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy