(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
| Days to Ship |
|
|---|

FA PSE Supported, 150 °C Heat-Resistant Fluorine Resin Insulated Cable
MISUMI
600 V heat-resistant single core wire. Tin-plated and annealed copper stranded wire is used for the conductor, so the continuous operating temperature is -60°C to 150°C.
| Standard Price: | MYR 98.13- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

UL3266 UL Standard Lead Free Irradiated Cross-Linked Flame Retardant PE Cable
HITACHI CABLE
• UL3266 type /UL (Underwriters Laboratories Inc.) standard supported
• Lead free irradiated cross-linked flame-retardant PE insulation as RoHS complied wires.
• Hitachi specification:SP23-90775F
• Appliance Wiring Material UL 758, CSA C22.2 No.127, No.210.2
• Flammability VW-1, FT1, -F
• 300V cable for flame retardant.
• Operating temperature range 125℃.
• Application Internal wiring for electronic equipment. Lead wires of coils
• Size range: 30~16AWG
• Insulation color: Black, White, Red, Green, Yellow, Blue, Brown, Orange, Gray, Violet
• Can order cable for 2 sizes of length 305m.
and 610m.
| Standard Price: | MYR 791.27- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

Cable NAUL1283 / NAUL1284 UL Supported
MISUMI
600 V international standard single core wire. You can purchase in units of 1 m.
| Standard Price: | MYR 2,676.53 |
|---|---|
| Days to Ship: | 4 Day(s) or more |

UL1430 UL Standard Lead Free Irradiated Cross-Linked PVC Cable
HITACHI CABLE
• UL1430 type /UL (Underwriters Laboratories Inc.) standard supported.
• Lead free PVC insulation as RoHS complied wires.
• Appliance Wiring Material UL 758, CSA C22.2 No.127, No.210.2
• Flammability VW-1, FT1, -F
• 300V cable for general purposes.
• Operating temperature range 105℃.
• Application Internal wiring for electric and electronic equipment, Motor lead wires.
• Size range: 30~16AWG
• Insulation color: Black, White, Red, Green, Yellow, Blue, Brown, Orange, Gray, Violet, Pink, Light blue
• Can order cable for 2 sizes of length 305m.
and 610m.
| Standard Price: | MYR 593.26- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

UL3265 UL Standard Lead Free Irradiated Cross-Linked Flame Retardant PE Cable
HITACHI CABLE
• UL3265 type /UL (Underwriters Laboratories Inc.) standard supported
• Lead free irradiated cross-linked flame-retardant PE insulation as RoHS complied wires.
• Hitachi specification:SP23-90775F
• Appliance Wiring Material UL 758, CSA C22.2 No.210.2
• Flammability VW-1, FT1, -F
• 150V cable for flame retardant.
• Operating temperature range 125℃.
• Application Internal wiring for hair dryers and small electric heaters.
• Size range: 30~20AWG
• Insulation color: Black, White, Red, Green, Yellow, Blue, Brown, Orange, Gray, Violet, Pink, Light blue
• Can order cable for 1 size of length 610m.
| Standard Price: | MYR 537.67- |
|---|---|
| Days to Ship: | 4 Day(s) or more |

Cable KIV PSE Compliant, Flexible Type
TAIYO CABLETEC
600 V general-purpose single-core wire.
[Features]
• Uses a flexible stranded conductor for superior flexibility.
• Sizes 0.75 to 100 mm2 conform to Electrical Appliance and Material Safety Laws of Japan.
| Standard Price: | MYR 69.58- |
|---|---|
| Days to Ship: | 10 Day(s) or more |

600 V vinyl insulated cable for electrical equipment KIV (includes bobbin (reel) winding)
KHD
A JIS C 3316 standard product: a cable made of bare soft copper stranded wire insulated with oil-resistant PVC.
[Features]
· More flexible than IV, making it ideal for space saving wiring
· Excellent oil resistance, water resistance, heat resistance, flexibility, and workability
[Applications]
· Used for wiring and lead wires in electrical equipment of 600 V AC or less
· Mainly used inside control panels, switchboards, etc.
[For bobbin roll / reel roll products]
· Products with "-R" at the end of part numbers are applicable.
| Standard Price: | MYR 65.18- |
|---|---|
| Days to Ship: | 10 Day(s) or more |

Global standard cable, CE-KIV series
KURAMO ELECTRIC
[Features]
· CE & CCC & UL/cUL (6 mm2 or less) & GOST-R Global Standard Cable
· Heat resistance (105°C)
[Applications]
· For internal wiring of equipment
| Standard Price: | MYR 584.63- |
|---|---|
| Days to Ship: | 12 Day(s) or more |

Global standard cable, KMTW series
KURAMO ELECTRIC
[Features]
· CE & UL/cUL & <PS>E (0.75 to 95 mm2) & TR-CU Global Standard Cable
· NFPA70, NFPA79 applicable (MTW, THW)
· Heat resistance
[Applications]
· For internal wiring of equipment and control panels
| Standard Price: | MYR 602.25- |
|---|---|
| Days to Ship: | 12 Day(s) or more |
| Brand |
|---|
| Product Series |
| Days to Ship |
| Specifications |
| Conductor Cross Section(mm2) |
| AWG size 1(AWG) |
| Sheath (outer coating) color |
| Rated Voltage 1 |
| Properties 1 |
| Overall Length(m) |
| Finished outer diameter(mm) |
| Representative Standard |
| Insulation body materials |
| Shield 1 |
| Logarithm |
| Sheath (outer coating) material |
| Type |
| Rated voltage |
| AWG Size(AWG) |
| Conductor Cross-Sectional Area(mm2) |
| Insulator Color |
| Bobbin (Reel) Roll Material |
| Bobbin (Reel) Roll |
| Total Length(m) |
| Safety standard |
| Insulator Material |
| Upper Temperature Limit |
| Overall Diameter(mm) |
| Properties |
| Shield |
| Processing Service |
| Brand | MISUMI | HITACHI CABLE | MISUMI | HITACHI CABLE | HITACHI CABLE | TAIYO CABLETEC | KHD | KURAMO ELECTRIC | KURAMO ELECTRIC |
|---|---|---|---|---|---|---|---|---|---|
| Product Series | FA PSE Supported, 150 °C Heat-Resistant Fluorine Resin Insulated Cable | UL3266 UL Standard Lead Free Irradiated Cross-Linked Flame Retardant PE Cable | UL1430 UL Standard Lead Free Irradiated Cross-Linked PVC Cable | UL3265 UL Standard Lead Free Irradiated Cross-Linked Flame Retardant PE Cable | 600 V vinyl insulated cable for electrical equipment KIV (includes bobbin (reel) winding) | ||||
| Days to Ship | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 4 Day(s) or more | 10 Day(s) or more | 10 Day(s) or more | 12 Day(s) or more | 12 Day(s) or more |
| Specifications |
|
| |||||||
| Conductor Cross Section(mm2) | 0.75 ~ 3.5 | - | 8 | - | - | 22 ~ 100 | 0.5 ~ 14 | 1.5 ~ 4 | 1 ~ 2.5 |
| AWG size 1(AWG) | 12 ~ 18 | 16 ~ 22 | 8 | 16 ~ 26 | 22 ~ 28 | - | - | 12 ~ 20 | 14 ~ 20 |
| Sheath (outer coating) color | Green | Green | Green | Green | Green | Green | Green | Green | Green |
| Rated Voltage 1 | 600V | - | 600V | - | - | 600V | 600V | 600V / 300V | 600V |
| Properties 1 | Heat-Resistance / Cold Resistance / Chemical Resistance | - | Heat-Resistance | - | - | - | Oil Resistance / Heat-Resistance | Heat-Resistance | Heat-Resistance |
| Overall Length(m) | 10 ~ 200 | 305 ~ 610 | 153 | 305 ~ 610 | 610 | - | 10 ~ 200 | 300 | 300 |
| Finished outer diameter(mm) | 1.9 ~ 3.3 | 1.58 ~ 2.35 | 7.2 | 1.48 ~ 2.53 | 0.98 ~ 1.36 | 9.9 ~ 18.7 | 2.5 ~ 7.7 | 2.2 ~ 4.3 | 2.65 ~ 3.3 |
| Representative Standard | PSE | UL / CSA(c-UL) | UL / CSA(c-UL) | UL / CSA(c-UL) | UL / CSA(c-UL) | PSE | PSE | UL / CE / CSA(c-UL) / CCC | PSE / UL / CE / CSA(c-UL) |
| Insulation body materials | - | - | - | PVC (Polyvinyl Chloride) | - | - | - | - | - |
| Shield 1 | NA | NA | NA | NA | NA | NA | NA | NA | NA |
| Logarithm | - | - | - | - | - | - | - | - | - |
| Sheath (outer coating) material | Other | - | PVC (Polyvinyl Chloride) | - | - | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) | PVC (Polyvinyl Chloride) |
| Type | - | - | - | - | - | KIV | KIV | KIV | MTW |
| Rated voltage | - | - | - | - | - | 600V | 600V | 300V / 600V | 600V |
| AWG Size(AWG) | - | - | - | - | - | - | - | 21 to 20 / 19 to 18 / 17 to 16 / 15 to 14 / 13 to 12 | 21 to 20 / 19 to 18 / 17 to 16 / 15 to 14 |
| Conductor Cross-Sectional Area(mm2) | - | - | - | - | - | 0.5 ~ 100 | 0.5 ~ 14 | 0.5 ~ 4 | 0.5 ~ 2.5 |
| Insulator Color | - | - | - | - | - | Green | Green | White | White / White/Blue (Straight) |
| Bobbin (Reel) Roll Material | - | - | - | - | - | - | Paper | - | - |
| Bobbin (Reel) Roll | - | - | - | - | - | N/A | Available / N/A | N/A | N/A |
| Total Length(m) | - | - | - | - | - | 10 ~ 200 | 10 ~ 200 | 100 ~ 300 | 300 |
| Safety standard | - | - | - | - | - | PSE | PSE | UL Recognized / CSA(c-UL) / CE / CCC | UL Listed / CSA(c-UL) / PSE / CE |
| Insulator Material | - | - | - | - | - | PVC | PVC | PVC | PVC |
| Upper Temperature Limit | - | - | - | - | - | Up to 100°C | Up to 100°C | Up to 100°C | Up to 100°C |
| Overall Diameter(mm) | - | - | - | - | - | 2.5 ~ 18.7 | 2.5 ~ 7.7 | 2.2 ~ 4.3 | 2.65 ~ 3.8 |
| Properties | - | - | - | - | - | - | Oil Resistance / Heat Resistance | Heat Resistance | Heat Resistance |
| Shield | - | - | - | - | - | N/A | N/A | N/A | N/A |
| Processing Service | - | - | - | - | - | N/A | N/A | N/A | N/A |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy