S-T Series (non-reversing) electromagnetic contactor
MITSUBISHI
Mitsubishi electromagnetic switch.
[Features]
· Global support.
· Twin contacts used for auxiliary contact.
· Terminal cover is standard equipment.
· Great satisfaction, condensed into a small unit.
[Applications]
· Convenient for motor start/stop and motor burnout protection.
| Days to Ship: | 8 Day(s) or more |
|---|

Electromagnetic Contactor SD-T (Non-reversible) Direct Current Operated Type
MITSUBISHI
Electromagnetic contactor with small size for many ratings.
[Features]
· DC operation type electromagnetic contactor.
· Smaller width dimension.
· Terminal cover is standard equipment.
· DC electromagnet with no noise.
| Days to Ship: | 51 Day(s) or more |
|---|

Magnetic DC Contactors SD-Q Series
MITSUBISHI
Small, high performance DC operation type contactor, which can be directly driven with transistor output (24 V DC 0.1 A).
[Features]
· Small, high performance DC operation type contactor, which can be directly driven with transistor output (24 V DC 0.1 A).
· This enables space saving because an interface relay is not required.
· Wiring is streamlined because wiring to a relay is not required, eliminating any mixture with AC control.
[Applications]
· Optimal for circuit interruption, heater switch, etc.
| Standard Price: | MYR 245.11 |
|---|---|
| Days to Ship: | Quote |

Magnetic Contactors SD-N Series
MITSUBISHI
Mitsubishi electromagnetic switch.
[Features]
· Use for DC operation of operation coil using a separate power supply.
[Applications]
· Optimal for motor start/stop and motor burnout protection.
| Days to Ship: | 9 Day(s) or more |
|---|

Solid State Contactors US-H Series
MITSUBISHI
Mitsubishi electromagnetic switch.
[Features]
· Uses power semiconductor element to enable long life when using as a high frequency switch.
[Applications]
· Optimal as a non-contact AC semiconductor contactor.
| Days to Ship: | Quote |
|---|

Magnetic Contactors reversible SD-2XT Series
MITSUBISHI
Magnetic Contactors reversible SD-2XT Series
Magnetic contactors are electromechanical switches that are used to control high-power electrical circuits
[Feature]
● Type : Reversing
● Coil Rated Voltage(V) : 24VDC
● Auxiliary Contact : 2a2b x 2
● Representative Standard : CE / UL / CUL / TUV / CCC / CSA
● Frame Size : T35, T80 and T100
[Application]
Magnetic contactors are typically used in industrial and commercial applications, such as motor control, lighting control and so on
| Days to Ship: | Quote |
|---|

Solid State Contactor For Heater G3PE (Three-Phase)
OMRON
· Compact, slim type with integrated heat sink.
· Solid state contactor for three-phase heater.
· Allows DIN rail mounting, helping to reduce installation work. (DIN rail mounting type)
[Features]
· Surge pass function improves surge dielectric strength of the output circuit. (In manufacturer's test conditions)
· Slim design with three-phase integrated construction.
· Available as DIN rail mounting type or screw mounting type.
· DIN rail mounting type allows DIN rail mounting as standard. (Compatible DIN rail: TR35-15Fe (IEC60715))
· UL, CSA and EN standard compliant (TÜV certified).
| Standard Price: | MYR 563.18- |
|---|---|
| Days to Ship: | 5 Day(s) or more |

Solid State Contactors US-N Series
MITSUBISHI
Mitsubishi electromagnetic switch.
[Features]
· Uses power semiconductor element to enable long life when using as a high frequency switch.
[Applications]
· Optimal as a non-contact AC semiconductor contactor.
| Days to Ship: | Quote |
|---|

Magnetic Contactors S-N Series
MITSUBISHI
Electromagnetic contactor for Mitsubishi electromagnetic switch.
[Features]
· Global support. Twin contacts used for auxiliary contact.
· High quality product meeting an increasing variety of needs.
[Applications]
· Optimal for motor start/stop and motor burnout protection.
| Days to Ship: | Quote |
|---|

Electromagnetic Contactor S-2XT Series (Reversing), AC Operated Type
MITSUBISHI
Magnetic Contactors S-2XT Series
Magnetic contactors are electromechanical switches that are used to control high-power electrical circuits
[Feature]
● Type : Reversing
● Coil Rated Voltage(V) : AC100 V and AC200V
● Auxiliary Contact : 1a x 2 +2b and 2a2b x2
● Applicable Standard : CE / UL / CUL / TUV / CCC / CSA
[Application]
Magnetic contactors are typically used in industrial and commercial applications, such as motor control, lighting control and so on
| Days to Ship: | Quote |
|---|

MS-T Series Contactor-Type Electromagnetic Relay SR-T AC Operation
MITSUBISHI
[Features]
·Fully adopts IEC 35mm rail mounting mechanism that can significantly reduce panel assembly time.
·Contact reliability is improved by adopting twin contacts on all surfaces.
·Easy-to-read coil rating
·Enhanced insulation between poles and between top and bottom contacts of the same pole
·Uses a self-up terminal screw that can securely tighten electric wires, round crimp terminals, and square crimp terminals.
·Equipped with a protective cover for the live parts as standard equipment
·In addition to the basic frame, there are also many applied products such as DC operation type and mechanical latch type.
| Days to Ship: | Quote |
|---|
| Brand |
|---|
| Product Series |
| CAD |
| Days to Ship |
| Type |
| Operating Method |
| Motor capacity 400 to 440-VAC class(kW/A) |
| Motor Capacity VAC 200–220 Class(kW/A) |
| Coil rated voltage(V) |
| Number of Poles |
| Auxiliary Contact |
| Representative Standard |
| Dimension length(mm) |
| Dimension width(mm) |
| Dimension thickness(mm) |
| Brand | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | OMRON | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Product Series | Electromagnetic Contactor SD-T (Non-reversible) Direct Current Operated Type | Electromagnetic Contactor S-2XT Series (Reversing), AC Operated Type | MS-T Series Contactor-Type Electromagnetic Relay SR-T AC Operation | ||||||||
| CAD |
| ||||||||||
| Days to Ship | 8 Day(s) or more | 51 Day(s) or more | Quote | 9 Day(s) or more | Quote | Quote | 5 Day(s) or more | Quote | Quote | Quote | Quote |
| Type | - | Electromagnetic Contact Device | - | - | - | - | Electromagnetic Contact Device | - | - | - | - |
| Operating Method | Irreversible type | Irreversible type | Irreversible type | Irreversible type | Irreversible type | Reversible format | - | Irreversible type | Irreversible type | Reversible format | Other |
| Motor capacity 400 to 440-VAC class(kW/A) | - | 4/9 ~ 45/93 | - | - | - | - | - | - | - | - | - |
| Motor Capacity VAC 200–220 Class(kW/A) | - | 2.7/13 ~ 22/100 | - | - | - | - | - | - | - | - | - |
| Coil rated voltage(V) | AC100V ~ AC400V | DC24V | DC24 | DC24 | DC 12–24 | DC24V | - | DC 12–24 | AC200 | AC100V ~ AC200V | AC200 |
| Number of Poles | - | 3 | 3 | 3 | 2 | - | 2 / 3 | 3 | 3 | - | - |
| Auxiliary Contact | 1a / 1b / 1a1b / 2a2b | 2a / 1a1b / 2a2b | 1b | 2a2b | - | Other | - | - | 2a2b | Other | Other |
| Representative Standard | TUV | TUV | TUV | TUV | TUV | TUV | TUV | TUV | TUV | TUV | TUV |
| Dimension length(mm) | 75 ~ 124 | 75 ~ 134 | 51 | 102 ~ 120 | 100 ~ 120 | 114 | 84.5 ~ 190.5 | 76 ~ 120 | 100 | 114 ~ 140 | 75 |
| Dimension width(mm) | 36 ~ 100 | 43 ~ 100 | 45 | 150 ~ 160 | 90 ~ 110 | 160 | 80 ~ 130.5 | 45 ~ 110 | 150 | 160 ~ 270 | 43 |
| Dimension thickness(mm) | 78 ~ 127 | 100 ~ 157 | 66.5 | 162 ~ 170 | 97 ~ 125 | 129 | 35 ~ 155 | 87 ~ 135 | 137 | 97 ~ 137 | 78 |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy