Earth Leakage Breakers (Low Capacity)(Mounting Method:Fasten With Screws)

Earth Leakage Circuit Breakers (ELCB), also known as an earth leakage switch or earth leakage protector, is an electrical safety device that detects and protects against electrical shock hazards caused by leakage current. When selecting an Earth Leakage Circuit Breaker (ELCB), it is crucial to consider factors such as Ampere frame, Number of Poles, Rate Current, Rate Operating, Voltage, Mounting Method (e.g., DIN rail mount, Fasten with screws, and etc.), and Size (height , width and depth). These considerations are vital for ensuring the production of high-quality products. We highly recommend reputable brands like MITSUBISHI , FUJI ELECTRIC , and NITTO KOGYO
Take advantage of the convenience of FREE SHIPPING and NO MINIMUM ORDER on the Earth Leakage Circuit Breaker (ELCB). If you have any doubts or require assistance in choosing the right product, our experts are readily available to provide advice and guidance.
Days to Ship
  • All
  • 1 Day(s) or Less
  • 2 Day(s) or Less
  • 4 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • 14 Day(s) or Less
  • 27 Day(s) or Less
  • 31 Day(s) or Less
  • 40 Day(s) or Less
  • 45 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Specifications
Ampere frame AF
Rated block capacity AC 100 V(kA)
Rated block capacity AC 200 V(kA)
Rated block capacity AC 400 V(kA)
Number of Poles
Rated Operating Voltage(V)
Rated Current(A)
rate sensitivity current(mA)
Mounting Method
Representative Standard
Dimension height(mm)
Dimension width(mm)
Dimension depth(mm)
Rated block capacity, voltages except VAC 100/200/400, VDC 250
Connection Method

    BH MINI Series Earth Leakage Circuit Breaker For Power Distribution Board

      High-Current Ground Leakage Breakers

        Earth Leakage Circuit Breaker NV-C Class (Economy Product) Harmonic/Surge Compatible NV125-CV

          UL 489 Listed No-Fuse Circuit Breaker With Earth Leakage Protection (Compatible with High Harmonics And Surges) NV250-CVFU

            Earth Leakage Circuit Breakers (ELCB) NV-L Series

              Earth Leakage Circuit Breaker NV-S Class (General Purpose Model) Compatible With High Harmonics And Surges

                Earth Leakage Circuit Breaker NV-S Class (Economy Model) Compatible With High Harmonics And Surges NV250-CV

                  Earth Leakage Circuit Breakers (ELCB) NV-NCV Series

                    Earth Leakage Circuit Breakers (ELCB) NV-SEV Series

                      Earth Leakage Breaker NV-S Class (General-Purpose Product) High Harmonics/ Surges Compatible NV250-SV

                        Leakage breaker NV-S class (general-purpose product) Harmonic/surge compatible type NV630-SW

                          Earth Leakage Circuit Breakers (ELCB) NV-NCV Series NV125-NCV

                            Earth Leakage Circuit Breakers (ELCB) NV-NCV Series NV250-NCV

                            Brand

                            MITSUBISHI

                            MISUMI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            MITSUBISHI

                            Product Series

                            BH MINI Series Earth Leakage Circuit Breaker For Power Distribution Board

                            High-Current Ground Leakage Breakers

                            Earth Leakage Circuit Breaker NV-C Class (Economy Product) Harmonic/Surge Compatible NV125-CV

                            UL 489 Listed No-Fuse Circuit Breaker With Earth Leakage Protection (Compatible with High Harmonics And Surges) NV250-CVFU

                            Earth Leakage Circuit Breakers (ELCB) NV-L Series

                            Earth Leakage Circuit Breaker NV-S Class (General Purpose Model) Compatible With High Harmonics And Surges

                            Earth Leakage Circuit Breaker NV-S Class (Economy Model) Compatible With High Harmonics And Surges NV250-CV

                            Earth Leakage Circuit Breakers (ELCB) NV-NCV Series

                            Earth Leakage Circuit Breakers (ELCB) NV-SEV Series

                            Earth Leakage Breaker NV-S Class (General-Purpose Product) High Harmonics/ Surges Compatible NV250-SV

                            Leakage breaker NV-S class (general-purpose product) Harmonic/surge compatible type NV630-SW

                            Earth Leakage Circuit Breakers (ELCB) NV-NCV Series NV125-NCV

                            Earth Leakage Circuit Breakers (ELCB) NV-NCV Series NV250-NCV

                            Days to Ship Quote 4 Day(s) or more 97 Day(s) or more Quote 51 Day(s) or more 9 Day(s) or more Quote Quote Quote Quote Quote Quote Quote
                            Specifications
                              • CE-Compliant
                              • IEC
                              • PSE Law
                              • RoHS
                              • KEMA
                              • Three-phase
                                                    Ampere frame AF50AF50AF / 60AF / 100AF to 199AF100AF to 199AFOther30AF or less30AF or lessOther100AF to 199AF100AF to 199AFOther400AF or higher100AF to 199AFOther
                                                    Rated block capacity AC 100 V(kA)5-30651 ~ 1.510 ~ 503630858585--
                                                    Rated block capacity AC 200 V(kA)2.530 ~ 3530-1 ~ -10 ~ 503630858585--
                                                    Rated block capacity AC 400 V(kA)--1036-5 ~ 3025-363650--
                                                    Number of Poles233323333 / 43333
                                                    Rated Operating Voltage(V)AC100 ~ AC100-200220AC100-440 ~ AC200-440AC120-480AC100 ~ AC100-200AC100 to 440AC100-440 ~ AC200-440100/200AC100-440AC100-440AC100-440AC100/200AC100/200
                                                    Rated Current(A)15 ~ 3015 ~ 10060 ~ 125200 ~ 25015 ~ 3015 ~ 50125 ~ 25010050 ~ 125125 ~ 250500 ~ 60060 ~ 125125 ~ 250
                                                    rate sensitivity current(mA)15 ~ 303030 ~ 100· 200· 500 switch100· 200· 500 switch10 ~ 3030 ~ 50030 ~ 100· 200· 500 switch30100· 200· 500 switch100· 200· 500 switch100· 200· 500 switch30 ~ 100· 200· 500 switch100· 200· 500 switch
                                                    Mounting MethodFasten With ScrewsFasten With ScrewsFasten With ScrewsFasten With ScrewsFasten With ScrewsFasten With ScrewsFasten With ScrewsFasten With ScrewsFasten With ScrewsFasten With ScrewsFasten With ScrewsFasten With ScrewsFasten With Screws
                                                    Representative StandardPSEPSE / CEPSECE / TUV / CCCPSE / CE / TUVPSE-PSEPSE-CEPSE-
                                                    Dimension height(mm)9513013018570130165130165165257130165
                                                    Dimension width(mm)2575901053275 ~ 9010590105 ~ 14010514090105
                                                    Dimension depth(mm)7760909246.590929092921559092
                                                    Rated block capacity, voltages except VAC 100/200/400, VDC 250-AvailableAvailableAvailableAvailableAvailableAvailable-AvailableAvailableAvailable--
                                                    Connection MethodSurface typeSurface typeSurface typeSurface typeSurface typeSurface type / Backside shapeSurface typeSurface typeSurface typeSurface typeSurface typeSurface typeSurface type