(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
| Days to Ship |
|
|---|
![EBS series (distribution-panel type leak breaker) [EBS32FB]](http://my.misumi-ec.com/linked/material/el/LSI1/PHOTO/LSI1_82.jpg?$product_view_b$)
EBS series (distribution-panel type leak breaker) [EBS32FB]
LSIS
[Features]
· Small space-saving leakage breaker for distribution board.
· The distribution board type is compact and can be used for distribution boards.
· Substantial lineup of rated current from 5 A to 100A.
· Height 96 mm, depth 60 mm, JIS agreement size.
· Easy attachment of auxiliary equipment.
· Passed testing, CE mark certified product.
· Types with a breaking capacity of 5kA or 10kA are available.
| Standard Price: | MYR 154.05- |
|---|---|
| Days to Ship: | 1 Day(s) or more |

MITSUBISHI
WS-V series NV-S type earth leakage circuit breaker (general-purpose product), F style.
[Features]
· Has a small size that is the smallest class in the industry, while maintaining conventional breaking performance.
· Standard support for mounting IEC 35 mm rail.
· Standard compatibility with protection grade IP20 from all directions of terminal area.
· Can mount operation handle.
· Voltage tripping device (SHT) can be mounted on the earth leakage circuit breaker.
[Applications]
· Earth leakage circuit breaker, F style.
| Days to Ship: | Quote |
|---|

Circuit breaker for control panel FA series (Earth leakage circuit breaker) NV30-FA
MITSUBISHI
Earth leakage circuit breaker for control panel.
[Features]
· Higher harmonics surge compatible type.
[Applications]
· Optimal for control panel earth leakage circuit breaker.
| Days to Ship: | 27 Day(s) or more |
|---|

Earth Leakage Circuit Breakers (ELCB) NV-SVF Series with CE/CCC
MITSUBISHI
Industry's smallest breaker was born. F Style (general purpose product) CE and CCC
| Days to Ship: | Quote |
|---|

Earth Leakage Circuit Breakers (ELCB) NV-L Series
MITSUBISHI
Mitsubishi low-voltage circuit breaker contributing to the future creation of electrical equipment.
Mitsubishi no-fuse breakers and earth leakage breakers that meet the needs of the market for over half a century.
Including WS-V series equipped with the latest breaker technology. Various product ranges are available to meet the needs of the distribution board and machinery market.
| Days to Ship: | 51 Day(s) or more |
|---|

Circuit Breaker For Controlboard FAU Series (Earth Leakage Circuit Breaker) NV30-FAU
MITSUBISHI
Mitsubishi low-voltage circuit breaker contributing to the future creation of electrical equipment.
Mitsubishi no-fuse breakers and earth leakage breakers that meet the needs of the market for over half a century.
Including WS-V series equipped with the latest breaker technology. Various product ranges are available to meet the needs of the distribution board and machinery market.
| Days to Ship: | 40 Day(s) or more |
|---|

MITSUBISHI
Size as is, increased blocking performance. (general-purpose product)
| Days to Ship: | 9 Day(s) or more |
|---|

Earth Leakage Circuit Breakers (ELCB) NV-KC Series with accessories
MITSUBISHI
A product series for basic protection of low-voltage circuits that consists of products ideal for shock protection
as well as protecting against overload and shorts.
| Days to Ship: | Quote |
|---|

MITSUBISHI
WS series NV-F type earth leakage breaker supporting higher harmonic surge (standard product).
[Features]
· Earth leakage breaker with earth leakage detection characteristics, unlikely to have unnecessary earth leakage tripping in response to higher harmonics or surges.
· Also applicable to inverter load because a higher harmonics and surge compatible IC is built in.
· Can provide IEC rail mounting as standard.
· Can mount on front surface, without tightening nuts from the back.
· Terminal structure allows back surface wiring.
[Applications]
· Earth leakage breaker supporting higher harmonic surge.
| Days to Ship: | 14 Day(s) or more |
|---|

Earth Leakage Circuit Breakers (ELCB) NV-CV Series (3P, AC100~400V, Rated Current sensitivity 30mA)
MITSUBISHI
Size as is, increased blocking performance. NV and MN type
| Days to Ship: | Quote |
|---|

Earth Leakage Circuit Breakers (ELCB) NV-KC Series
MITSUBISHI
One-touch installation improves work efficiency, reducing distribution board manufacturing time, as well as shortening power outage time during expansion or specification changes.
| Days to Ship: | Quote |
|---|

MITSUBISHI
[Specifications]
- Ampere Frame (AF): 30 AF
- Rated Block Capacity AC 100V (kA): 1.5
- Rated Block Capacity AC 200V (kA): 1.5
- Number of Poles: 2
- Rated Current (A): 15/20
| Days to Ship: | Quote |
|---|

Earth Leakage Circuit Breakers (ELCB) NV-FA Series
MITSUBISHI
In addition to overload and short-circuit protection in low-voltage circuit, this product series also offers the most optimal protection against electric shock as well as
basic protection for low-voltage circuits.
| Days to Ship: | Quote |
|---|

Circuit breaker for distribution board and control board KC series NV30-KC
MITSUBISHI
Mitsubishi low-voltage circuit breaker contributing to the future creation of electrical equipment.
Mitsubishi no-fuse breakers and earth leakage breakers that meet the needs of the market for over half a century.
Including WS-V series equipped with the latest breaker technology. Various product ranges are available to meet the needs of the distribution board and machinery market.
| Days to Ship: | Quote |
|---|
Earth Leakage Circuit Breakers (ELCB) NV-CS Series
MITSUBISHI
Mitsubishi low-voltage circuit breaker contributing to the future creation of electrical equipment.
Mitsubishi no-fuse breakers and earth leakage breakers that meet the needs of the market for over half a century.
Including WS-V series equipped with the latest breaker technology. Various product ranges are available to meet the needs of the distribution board and machinery market.
| Days to Ship: | Quote |
|---|
| Brand |
|---|
| Product Series |
| CAD |
| Days to Ship |
| Ampere frame AF |
| Rated block capacity AC 100 V(kA) |
| Rated block capacity AC 200 V(kA) |
| Rated block capacity AC 400 V(kA) |
| Number of Poles |
| Rated Operating Voltage(V) |
| Rated Current(A) |
| rate sensitivity current(mA) |
| Mounting Method |
| Representative Standard |
| Dimension height(mm) |
| Dimension width(mm) |
| Dimension depth(mm) |
| Rated block capacity, voltages except VAC 100/200/400, VDC 250 |
| Connection Method |
| Brand | LSIS | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Product Series | Circuit breaker for control panel FA series (Earth leakage circuit breaker) NV30-FA | Earth Leakage Circuit Breakers (ELCB) NV-SVF Series with CE/CCC | Circuit Breaker For Controlboard FAU Series (Earth Leakage Circuit Breaker) NV30-FAU | Earth Leakage Circuit Breakers (ELCB) NV-KC Series with accessories | Earth Leakage Circuit Breakers (ELCB) NV-CV Series (3P, AC100~400V, Rated Current sensitivity 30mA) | Circuit breaker for distribution board and control board KC series NV30-KC | |||||||||
| CAD |
| ||||||||||||||
| Days to Ship | 1 Day(s) or more | Quote | 27 Day(s) or more | Quote | 51 Day(s) or more | 40 Day(s) or more | 9 Day(s) or more | Quote | 14 Day(s) or more | Quote | Quote | Quote | Quote | Quote | Quote |
| Ampere frame AF | 30AF or less | 30AF or less | 30AF or less | 30AF or less | 30AF or less | 30AF or less | 30AF or less | 30AF or less | 30AF or less | 30AF or less | 30AF or less | 30AF or less | 30AF or less | 30AF or less | 30AF or less |
| Rated block capacity AC 100 V(kA) | - | 7.5 | 1.5 ~ 2.5 | 7.5 | 1 ~ 1.5 | 2.5 | 10 | 5 | 1.5 ~ 2.5 | 2.5 | 5 | 1.5 | 2.5 | 5 | 2.5 |
| Rated block capacity AC 200 V(kA) | 5 | 7.5 | 1.5 ~ 2.5 | 7.5 | 1 ~ - | 2.5 | 10 | 5 | 1.5 ~ 2.5 | 2.5 | 5 | 1.5 | 2.5 | 5 | 2.5 |
| Rated block capacity AC 400 V(kA) | - | 5 | - | - | - | - | 5 | - | - | - | - | - | - | - | - |
| Number of Poles | 2 / 3 | 2 / 3 | 2 / 3 | 2 | 2 | 2 / 3 | 3 | 3 | 2 / 3 | 3 | 3 | 2 | 2 / 3 | 3 | 3 |
| Rated Operating Voltage(V) | 100 to 220 | AC100-440 ~ AC100 to 440 | AC100-200 ~ AC100 to 200 | AC 100–240 | AC100 ~ AC100-200 | AC100-240 | 100-440V ~ AC100 to 440 | 100 to 200 | AC100 to 200 | AC100 to 230 | AC100 to 200 | - | 100-200 | AC100-200 | AC100 to 230 |
| Rated Current(A) | 5 ~ 30 | 10 ~ 30 | 5 ~ 30 | 15 | 15 ~ 30 | 10 ~ 30 | 10 ~ 30 | 15 ~ 30 | 5 ~ 30 | 4 | 5 ~ 10 | 15 / 20 | 10 ~ 30 | 5 ~ 30 | 10 |
| rate sensitivity current(mA) | 30 | 30 ~ 100 | 15 ~ 30 | 30 | 10 ~ 30 | 30 | 30 ~ 500 | 30 | 30 | 30 | 30 | - | 15 ~ 30 | 30 | 15 |
| Mounting Method | DIN rail mount | DIN/Screw retention | DIN/Screw retention | DIN/Screw retention | Fasten With Screws | DIN/Screw retention | DIN rail mount / Fasten With Screws | DIN/Screw retention | DIN/Screw retention | DIN/Screw retention | DIN/Screw retention | - | DIN/Screw retention | DIN/Screw retention | DIN/Screw retention |
| Representative Standard | PSE / CE | PSE / CE / TUV | PSE | PSE / CE / TUV / CCC | PSE / CE / TUV | PSE / CE / TUV / CCC | PSE | PSE | PSE / CE / TUV / CCC | PSE | PSE | - | PSE | PSE | PSE |
| Dimension height(mm) | 96 | 100 | 72 | 100 | 70 | 72 | 130 | 96 | 72 | 96 | 124.5 | - | 72 | 96 | 96 |
| Dimension width(mm) | 50 ~ 75 | 36 ~ 54 | 40 ~ 60 | 36 | 32 | 40 ~ 60 | 75 | 75 | 40 ~ 60 | 67.5 | 75 | - | 40 ~ 60 | 75 | 67.5 |
| Dimension depth(mm) | 80 | 90 | 73.5 | 90 | 46.5 | 73.5 | 90 | 76 | 73.5 | 67 | 76 | - | 73.5 | 76 | 67 |
| Rated block capacity, voltages except VAC 100/200/400, VDC 250 | Available | Available | - | - | Available | Available | Available | - | - | - | - | - | - | - | Available |
| Connection Method | Surface type | Surface type | Surface type | Surface type | Surface type | Surface type | Surface type / Backside shape | Surface type | Surface type | Surface type | Surface type | - | Surface type | Surface type | Surface type |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy