Circuit Breakers (Low Capacity)(Ampere frame:63AF)

Days to Ship
  • All
  • 4 Day(s) or Less
  • 8 Day(s) or Less
  • 9 Day(s) or Less
  • 16 Day(s) or Less
  • 21 Day(s) or Less
  • 23 Day(s) or Less
  • 26 Day(s) or Less
  • 32 Day(s) or Less
  • 41 Day(s) or Less
  • 81 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Ampere frame
Rated block capacity AC 100 V(kA)
Rated block capacity AC 200 V(kA)
Rated block capacity AC 400 V(kA)
Rated Braking Capacity at Rated Voltage of VDC 250(kA)
Rated block capacity, voltages except VAC 100/200/400, VDC 250
Number of Poles
Rated Current(A)
Mounting Method
Connection Method
Representative Standard
Dimension height(mm)
Dimension width(mm)
Dimension depth(mm)

    Molded Case Circuit Breakers (MCCB) NF-CS Series

      Molded Case Circuit Breakers (MCCB) NF-SVF Series with accessories

        Earth Leakage Circuit Breakers (ELCB) NV-ZCV Series

        Brand

        MITSUBISHI

        MITSUBISHI

        MITSUBISHI

        Product Series

        Molded Case Circuit Breakers (MCCB) NF-CS Series

        Molded Case Circuit Breakers (MCCB) NF-SVF Series with accessories

        Earth Leakage Circuit Breakers (ELCB) NV-ZCV Series

        Days to Ship Quote Quote Quote
        Ampere frame63AF63AF63AF
        Rated block capacity AC 100 V(kA)--7.5 ~ 15
        Rated block capacity AC 200 V(kA)7.5157.5 ~ 15
        Rated block capacity AC 400 V(kA)5105 ~ 7.5
        Rated Braking Capacity at Rated Voltage of VDC 250(kA)2.5--
        Rated block capacity, voltages except VAC 100/200/400, VDC 250AvailableAvailableAvailable
        Number of Poles333
        Rated Current(A)5020 ~ 6015 ~ 60
        Mounting MethodDIN rail mountDIN rail mountDIN rail mount
        Connection MethodSurface typeSurface typeSurface type
        Representative StandardPSE / CE / CCCPSE / CE / CCCPSE
        Dimension height(mm)130100130
        Dimension width(mm)755475
        Dimension depth(mm)909090