CC-Link IE Field Network Basic, Block Type Remote Unit
MITSUBISHI
[CC-Link IE Field Network, Basic Block Type Remote Unit]
・ CC-Link IE field network Basic slave station. Input/output devices can be more easily distributed according to the equipment
・ It supported for CC-Link IE Field Network Basic diagnostic function. With the engineering tool, you can check for network abnormalities and input/output unit abnormalities
・ Parameters can be easily set with just a switch operation
| Special Price | |
| Days to Ship: | 97 Day(s) or more |

MITSUBISHI
- I/O module, iQ-R series from MITSUBISHI.
- Input/output rating is printed at the front, reducing incorrect wiring.
- Easy-to-use cable tie hook for tidy wiring.
- Existing 16-point terminal blocks are reusable, eliminating rewiring.
- Simple confirmation by product serial no. printed on the front.
- Alternating toggle switch used to display between 32-point LED signals.
- Terminal signals are clearly labeled and color-coded.
- Up to 32 LED signals clearly visible.
| Standard Price: | MYR 703.33- |
|---|---|
| Special Price | |
| Days to Ship: | 4 Day(s) or more |

CC-Link IE Field Network, Block Type Remote Unit NZ2GN Series
MITSUBISHI
The block type remote unit is a slave station of the CC-Link IE TSN network.
[Features]
・Input/output devices can be more easily distributed according to the equipment
・The input/output unit can be connected to various devices that handle ON/OFF signals, such as switches, sensors, and actuators that are the basis of control systems
・The analog unit can be connected to devices that handle analog values such as voltage and current
・In addition, safe communication can be realized by combining a block type remote unit with a safety function with a safety CPU
・Parameters can be easily set with just a switch
・It can detect the power supply voltage drop of the unit
・Wiring labor-hours can be reduced by the spring clamp terminal block
・The input unit complies with IEC61131-2 (digital input standard operating range) Type3, and various sensors can be connected
・It can also operate as a slave station of CC-Link IE field network
・Safety control is also possible with a block type remote unit with a safety function
・Since the input/output timing can be adjusted to the synchronization cycle between units, highly accurate control of the system is possible
| Standard Price: | MYR 1,706.66- |
|---|---|
| Special Price | |
| Days to Ship: | 97 Day(s) |

CC-Link IE Field Network block-type remote unit NZ2GF Series
MITSUBISHI
[CC-Link IE Field Network, Block Type Remote Unit]
・ CC-Link IE field network remote device station. Input/output devices can be more easily distributed according to the equipment
・ You can easily add the number of input/output points by connecting expansion units
・ It supports CC-Link IE field network synchronous communication function. Since the operation can be performed according to the synchronization cycle of the master station that supports the synchronous communication function, the operation timings of multiple slave stations can be aligned
・ Units that support the fast link-up function can quickly return to the line when the CC-Link IE field network is disconnected and then reconnected
・ Units that support the automatic I/O parameter setting function can operate the input/output unit without setting parameters, so the startup time can be shortened
| Special Price | |
| Days to Ship: | 4 Day(s) or more |
| Brand |
|---|
| Product Series |
| Days to Ship |
| Number Of Inputs |
| Input Format |
| Rated Input Voltage(V) |
| Input answer time |
| Number of Outputs |
| Output Format |
| Rated load voltage(V) |
| Protection function |
| Connection Terminal |
| Representative Standard |
|
|
|
| |
| Brand | MITSUBISHI | MITSUBISHI | MITSUBISHI | MITSUBISHI |
| Product Series | CC-Link IE Field Network, Block Type Remote Unit NZ2GN Series | CC-Link IE Field Network block-type remote unit NZ2GF Series | ||
| Days to Ship | 97 Day(s) or more | 4 Day(s) or more | 97 Day(s) | 4 Day(s) or more |
| Number Of Inputs | 16 ~ 32 | 16 ~ 64 | 8 ~ 32 | 16 ~ 32 |
| Input Format | DC input / AC input | DC input | DC input | DC input / AC input |
| Rated Input Voltage(V) | DC24 ~ 100-120 | DC5 ~ DC24 | 24 | 24 ~ 100~120 |
| Input answer time | Less than 50 to 100 mS | Less than 50 to 100 mS | Less than 50 to 100 mS | Less than 50 to 100 mS |
| Number of Outputs | 16 | 32 ~ NA | 8 ~ 16 | 16 |
| Output Format | Transistor / source output / Transistor / sync output | Transistor / sync output | Transistor / source output / Transistor / sync output | Transistor / source output / Transistor / sync output |
| Rated load voltage(V) | 24 ~ DC24 | DC12 to 24 | DC12/24 ~ DC24 | 12/24 ~ 24 |
| Protection function | None | None / Input protection function / Output protection function | None / Output protection function | None |
| Connection Terminal | Terminal Block | Terminal Block / Connector / Europe terminal block | Terminal Block / Connector | Terminal Block / Connector |
| Representative Standard | CE / UL / CUL | CE / UL / CUL | CE / UL / CUL | CE / UL / CUL |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy