PLC (Input/Output Units)(Connection Terminal:Terminal Block)

PLCs (Input/Output Units), formally called "programmable logic controllers," are components used as an interface between devices and sequencers. They work by controlling the on/off switching of the output device using a preset program that operates in response to the on/off switching of switches and sensors. They were initially developed as an alternative to relay circuits and are used in controls for boilers, pumps, automated machinery that operate inside factories, and more. PLCs are broadly divided into 2 types, modular type and packaged type. Modular types require input components and standalone units to be combined and allow for more freedom of customization. Packaged types are totally pre-assembled to offer an inexpensive installation solution.
Days to Ship
  • All
  • 2 Day(s) or Less
  • 4 Day(s) or Less
  • 5 Day(s) or Less
  • 9 Day(s) or Less
  • 13 Day(s) or Less
  • 60 Day(s) or Less
  • 65 Day(s) or Less
  • 79 Day(s) or Less
  • 82 Day(s) or Less
  • 90 Day(s) or Less
  1. 1
Brand
Product Series
Days to Ship
Number Of Inputs
Input Format
Rated Input Voltage(V)
Input answer time
Number of Outputs
Output Format
Rated load voltage(V)
Protection function
Connection Terminal
Representative Standard

    CJ Series Output Unit CJ1W-OC / OA / OD

    • On Sale Till 30/06/2026

    CC-Link IE Field Network Basic, Block Type Remote Unit

      Programmable Controller CP1L Expansion I/O Unit

      • On Sale Till 30/06/2026

      iQ-R Series input/output unit

        I/O control unit I/O interface unit

          Input/Output Unit CS1W

          • On Sale Till 30/06/2026

          CC-Link IE Field Network Remote I/O Unit With Safety Function

          • On Sale Till 30/06/2026

          MELSEC CC-Link compact type remote I/O unit (input/output unit)

            NX Series Digital Output Unit NX-OD Transistor Output Unit

            • On Sale Till 30/06/2026

            MELSEC iQ-F Input/Output Expansion Block (Input/Output Unit) FX5

            • On Sale Till 30/06/2026

            CC-Link IE Field Network, Block Type Remote Unit NZ2GN Series

            • On Sale Till 30/06/2026

            Expansion unit for CC-Link IE Field Network block-type remote unit

            • On Sale Till 30/06/2026

            CC-Link IE Field Network block-type remote unit NZ2GF Series

            Brand

            OMRON

            MITSUBISHI

            OMRON

            MITSUBISHI

            OMRON

            OMRON

            MITSUBISHI

            MITSUBISHI

            OMRON

            MITSUBISHI

            MITSUBISHI

            MITSUBISHI

            MITSUBISHI

            Product Series

            CJ Series Output Unit CJ1W-OC / OA / OD

            CC-Link IE Field Network Basic, Block Type Remote Unit

            Programmable Controller CP1L Expansion I/O Unit

            iQ-R Series input/output unit

            I/O control unit I/O interface unit

            Input/Output Unit CS1W

            CC-Link IE Field Network Remote I/O Unit With Safety Function

            MELSEC CC-Link compact type remote I/O unit (input/output unit)

            NX Series Digital Output Unit NX-OD Transistor Output Unit

            MELSEC iQ-F Input/Output Expansion Block (Input/Output Unit) FX5

            CC-Link IE Field Network, Block Type Remote Unit NZ2GN Series

            Expansion unit for CC-Link IE Field Network block-type remote unit

            CC-Link IE Field Network block-type remote unit NZ2GF Series

            Days to Ship 2 Day(s) or more 97 Day(s) or more 2 Day(s) or more 4 Day(s) or more 5 Day(s) or more 5 Day(s) or more 97 Day(s) 4 Day(s) or more 5 Day(s) or more 97 Day(s) 97 Day(s) 97 Day(s) 4 Day(s) or more
            Number Of Inputs-16 ~ 328 ~ 248 ~ NA8164 (for double wiring) ~ 32 (single wire)4 ~ 16-4 ~ 816 ~ 321616 ~ 32
            Input Format-DC input / AC inputDC inputDC input / AC inputDC inputDC input / AC input / AC/DC inputDC inputDC input / AC input-DC inputDC inputDC inputDC input / AC input
            Rated Input Voltage(V)-DC24 ~ 100-120-DC5/12 ~ AC100 to 24012–2424 ~ 200 to 24024DC24V ~ AC100/120V-DC13 to 30 ~ DC24242424 ~ 100~120
            Input answer time-Less than 50 to 100 mS-Less than 10 to 20 mS / Less than 50 to 100 mS---Less than 1 mS / Less than 1 to 10 mS / Less than 20 to 50 mS--Less than 50 to 100 mS-Less than 50 to 100 mS
            Number of Outputs8 ~ 1616 ~ 328 ~ 328 ~ NA-8 ~ 168 (for single wiring), 4 (for double wiring)4 ~ 322 ~ 164 ~ 816 ~ 321616 ~ 32
            Output FormatRelay contact output / Triac output / Transistor / source output / Transistor / sync outputRelay contact output / Transistor / source output / Transistor / sync outputRelay contact output / Transistor / source output / Transistor / sync outputRelay contact output / Triac output / Transistor / source output / Transistor / sync output / Other-Relay contact output / Triac output / Transistor / source output / Transistor / sync outputTransistor / source outputRelay contact output / Transistor / source output / Transistor / sync outputOtherTransistor / source output / Transistor / sync outputTransistor / source output / Transistor / sync outputTransistor / source output / Transistor / sync outputRelay contact output / Triac output / Transistor / source output / Transistor / sync output
            Rated load voltage(V)-12 ~ 240 AC-DC12 to 24 ~ AC100~240--24DC12/24V ~ DC24V/AC240V--DC12/24 ~ DC2412$2412/24 ~ AC100~240
            Protection functionOutput protection functionNone-None / Input protection function / Output protection function--Input protection function / Output protection functionNone / Output protection function--None / Output protection functionNoneNone
            Connection TerminalTerminal BlockTerminal BlockTerminal BlockTerminal BlockTerminal BlockTerminal BlockTerminal BlockTerminal BlockTerminal BlockTerminal BlockTerminal BlockTerminal BlockTerminal Block
            Representative StandardCE / UL / CUL / CSACE / UL / CULCE / UL / CSACE / UL / CULCE / UL / CUL / CSACE / UL / CUL / CSA-CE / UL / CULCE / UL / CUL / CSACE / UL / CULCE / UL / CUL-CE / UL / CUL

            Loading...

            1. 1