[Features]
· Compression type.
· Optimal for measuring load distribution.
· Ideal for measuring press fitting and press pressure changes.
· Includes cell mounting bracket and amplifier case mounting bracket.
· Rated capacity: 100 N (10.20 kg) to 1 kN (102.0 kg).
· Analog output with amplification makes weight calibration unnecessary.
· Optimal for measuring load distribution.
· For button switch pressure measurement.
· For component force measurement.
| Part Number |
|---|
| LCCA21KN001 |
| LCCA21N100 |
| LCCA21N200 |
| LCCA21N500 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | JAN Code | Rated capacity | Natural frequency (kHz) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|
MYR 2,099.53 | 1 Piece(s) | 11 Day(s) | 4981046612234 | 1 kN (102.0 kg) | 35 | Approx. 0.070 (including amplifier and cable) | ||
MYR 2,099.43 | 1 Piece(s) | 11 Day(s) | 4981046612203 | 100 N (10.20 kg) | 45 | Approx. 0.065 (including amplifier and cable) | ||
MYR 2,099.46 | 1 Piece(s) | 11 Day(s) | 4981046612210 | 200 N (20.39 kg) | 55 | Approx. 0.065 (including amplifier and cable) | ||
MYR 2,099.49 | 1 Piece(s) | 11 Day(s) | 4981046612227 | 500 N (50.99 kg) | 30 | Approx. 0.070 (including amplifier and cable) |
Loading...
| Main applications | Peripheral Equipment | Type | Main Body | Dust-proof and waterproof function | Available |
|---|---|---|---|---|---|
| Allowable overload(% of R.C.) | 150 | Overall error(% of R.O.) | 0.5 | Power supply voltage(V) | DC 5 ±0.25 |
| Output voltage(V) | 1 to 4 (applied load [% of R.C.] 0%: 1, 100%: 3, 150%: 4) | Details of dust-proof and waterproof function | Dust-proof, waterproofing performance: load cell IP64 | Operating temperature and humidity range | 0°C to 70°C |
| Accessory | Mounting holder, amplifier case holder | Operating environment(°C) | -10 to 80 | Power supply current consumption | ≤ 16 mA |
| Load resistance | ≥ 5 kΩ | Zero point voltage(V) | 1 ±0.04 | Span voltage(V) | 2 ±0.01 |
| Insulation resistance | ≥ 500 MΩ/ 50 V DC (not insulated between power supply and output) | Effect of zero point temperature | 0.6% of R.O. / 10°C Typ. | Effect of output temperature | 0.6% of Load / 10°C Typ. |
| Frequency characteristics(Hz) | 100 (-3 dB) | Cable size | Load cell to amplifier: ø2 / 2 m, From amplifier: ø6 / 0.5 m | Cable color | Red: power source +, white: power source -, green: output +, blue: output -, yellow: shield |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy