(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
[CC-Link IE Field Network, Block Type Remote Unit]
・ CC-Link IE field network remote device station. Input/output devices can be more easily distributed according to the equipment
・ You can easily add the number of input/output points by connecting expansion units
・ It supports CC-Link IE field network synchronous communication function. Since the operation can be performed according to the synchronization cycle of the master station that supports the synchronous communication function, the operation timings of multiple slave stations can be aligned
・ Units that support the fast link-up function can quickly return to the line when the CC-Link IE field network is disconnected and then reconnected
・ Units that support the automatic I/O parameter setting function can operate the input/output unit without setting parameters, so the startup time can be shortened
Part Number
Configured Part Number is shown.
NZ2GF2S2-16A
| Part Number |
|---|
| NZ2GF2S2-16A |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Number Of Inputs | Input Format | Rated Input Voltage (V) | Input answer time | Number of Outputs | Output Format | Rated load voltage (V) | Connection Terminal | Representative Standard | Features | Rated input current (mA) | Max Load Current | Terminal Shape | Type of Unit | External connection | Input format details | Wiring | Int. Current Consumption (A) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 16 | AC input | 100~120 | Less than 50 to 100 mS | - | - | - | Terminal Block | - | Number of connectable expansion units: 1 | 6.8(50Hz)/8.2(60Hz) | - | Spring clamp | Basic Input Unit | 2-wire | - | - | - |
Loading...
| Protection function | None |
|---|
Please check the type/dimensions/specifications of the part NZ2GF2S2-16A in the CC-Link IE Field Network block-type remote unit NZ2GF Series series.
| Part Number |
|---|
| NZ2GF2B1-32T |
| NZ2GF2B1-32TE |
| NZ2GF2B1N1-16D |
| NZ2GF2S2-16R |
| NZ2GF2S2-16S |
| NZ2GFCE3-16D |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Number Of Inputs | Input Format | Rated Input Voltage (V) | Input answer time | Number of Outputs | Output Format | Rated load voltage (V) | Connection Terminal | Representative Standard | Features | Rated input current (mA) | Max Load Current | Terminal Shape | Type of Unit | External connection | Input format details | Wiring | Int. Current Consumption (A) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 2,505.00 | 1 Piece(s) | 4 Day(s) | - | DC input | - | - | 32 | Transistor / sync output | 12/24 | Terminal Block | CE / CUL / UL | Expansion unit connection not possible | - | 0.5A | Screw | Basic output unit | 1‑wire method | - | Screw | 0,13 | ||
MYR 2,505.00 | 1 Piece(s) | 97 Day(s) | - | - | - | - | 32 | Transistor / source output | 12/24 | Terminal Block | - | Expansion unit connection not possible | - | 0.5 A | Screw | Basic output unit | 1‑wire method | - | - | - | ||
MYR 1,281.67 | 1 Piece(s) | 4 Day(s) | 16 | DC input | 24 | Less than 50 to 100 mS | - | - | - | Terminal Block | - | Number of expansion units that can be connected: 3 | 6 | - | Spring clamp | Basic input unit | 1-wire type | Positive common / negative common | - | - | ||
MYR 2,663.33 | 1 Piece(s) | 97 Day(s) | - | - | - | - | 16 | Relay contact output | DC24/AC240 | Terminal Block | - | Number of connectable expansion units: 1 | - | 2A | Spring clamp | Basic output unit | 2-wire | - | - | - | ||
- | 1 Piece(s) | Quote | - | - | - | - | 16 | Triac output | 100 to 240 AC | Terminal Block | - | Number of expansion units that can be connected: 1 | - | 0.6A | Spring clamp | Basic output unit | 2-wire type | - | - | - | ||
MYR 3,130.00 | 1 Piece(s) | 97 Day(s) | 16 | DC input | 24 | Less than 50 to 100 mS | - | - | - | Connector | - | Number of connectable expansion units: 1 | 4 | - | Sensor connector (e-CON) | Basic Input Unit | 3‑wire method | + Common | - | - |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy