Part Number
Configured Part Number is shown.
CPX-FB6

CPX-FB36

CPX-FB13

CPX-M-FB34
| Type | CPX-FB36 | ||
|---|---|---|---|
| Fieldbus interface | 2x M12x1 socket, D-coded, 4-pin | ||
| Baud rates [Mbit/s] | 10/100 | ||
| Protocol | EtherNet/IP | ||
| Modbus TCP | |||
| Max. address capacity, inputs [byte] | 64 | ||
| Max. address capacity, outputs[byte] | 64 | ||
| LED displays (bus-specific) | MS NS TP1 TP2 | = Module status = Network status = Network active port 1 = Network active port 2 | |
| Device-specific diagnostics | Module and channel-oriented diagnostics Module undervoltage Diagnostic memory | ||
| Configuration support | EDS file L5K export with CPX-FMT | ||
| Parameterisation | Diagnostic behaviour Fail-safe response Forcing of channels Idle mode characteristics Signal setup System parameters | ||
| Additional functions | EtherNet/IP Quickconnect Ring topology (DLR) Acyclic data access via "Explicit Message" and Ethernet Integrated switch IP addressing via DHCP, DIL switch or operator unit Channel-oriented diagnostics via fieldbus Start-up parameterisation in plain text via fieldbus System status can be represented using process data Additional diagnostic interface for operator units | ||
| Control elements | DIL switches | ||
| Operating voltage | Nominal value [V DC] | 24 | |
| Permissible range [V DC] | 18 to 30 | ||
| Current consumption (at nominal voltage) [mA] | Typically 100 | ||
| Protection class to EN 60529 | IP65, IP67 | ||
| Temperature range | Operation [℃] | -5 to +50 | |
| Storage/transport [℃] | -20 to +70 | ||
| Materials | PA reinforced | ||
| Note on materials | RoHS-compliant | ||
| Grid dimension [mm] | 50 | ||
| Dimensions (incl. interlinking block) W x L x H [mm] | 50 x 107 x 50 | ||
| Product weight [g] | 125 | ||
| Type | CPX-FB13 | |
|---|---|---|
| Fieldbus interface | Sub-D socket, 9-pin (EN 50 170) Galvanically isolated 5 V | |
| Baud rate [Mbit/s] | 0.0096 to 12 | |
| Addressing range | 1 to 125 Set using DIL switch | |
| Product range | 4: Valves | |
| Ident. number | 0x059E | |
| Communication types | DPV0: Synchronous communication DPV1: Asynchronous communication | |
| Configuration support | GSD file and bitmaps | |
| Max. address capacity | Inputs [byte] | 64 |
| Outputs [byte] | 64 | |
| LED displays (bus-specific) | BF: Bus fault | |
| Device-specific diagnostics | Identifier and channel-oriented diagnostics EN 50170 (PROFIBUS standard) | |
| Parameterisation | Start-up parameterisation via configuration interface in plain text (GSD) Asynchronous parameterisation via DPV1 | |
| Additional functions | Storage of the last 40 errors with timestamp (access via DPV1) 8-bit system status in image table for inputs 2-byte inputs and 2-byte outputs, system diagnostics in image table | |
| Control elements | DIL switch | |
| Operating voltage | Nominal value [V DC] | 24 |
| Permissible range [V DC] | 18 to 30 | |
| Power failure buffering [ms] | 10 | |
| Current consumption | Typically 200 | |
| Protection class to EN 60529 | IP65, IP67 | |
| Temperature range | Operation | -5 to +50 |
| Storage/transport | -20 to +70 | |
| Materials | PA-reinforced PC | |
| Grid dimension | 50 | |
| Dimensions (incl. interlinking block) W x L x H | 50 x 107 x 50 | |
| Weight | 115 | |
| Type | CPX-M-FB34 | ||
|---|---|---|---|
| Fieldbus interface | 2x RJ45 push-pull socket, AIDA | ||
| Baud rate [Mbit/s] | 100 | ||
| Protocol | PROFINET RT | ||
| PROFINET IRT | |||
| Max. address capacity | Inputs [byte] | 64 | |
| Outputs [byte] | 64 | ||
| LED displays | (bus-specific) | M/P NF TP1 TP2 | = Maintenance/PROFIenergy = Network fault = Network active port 1 = Network active port 2 |
| (product-specific) | M PL PS SF | = Modify, parameterisation = Load supply = Electronic supply, sensor supply = System fault | |
| Device-specific diagnostics | Channel and module-oriented diagnostics Undervoltage of modules Diagnostic memory | ||
| Configuration support | GSDML file | ||
| Parameterisation | System parameters Diagnostic behaviour Signal setup Fail-safe response Forcing of channels | ||
| Additional functions | Start-up parameterisation in plain text via fieldbus Fast startup (FSU) Channel-oriented diagnostics via fieldbus Asynchronous data access via fieldbus and via Ethernet System status can be represented using process data Additional diagnostic interface for operator units | ||
| Control elements | DIL switch, optional memory card | ||
| Operating voltage | Nominal value [V DC] | 24 | |
| Permissible range [V DC] | 18 to 30 | ||
| Intrinsic current consumption at nominal operating voltage [mA] | Typically 120 | ||
| Protection class to EN 60529 | IP65, IP67 | ||
| Temperature range | Operation [℃] | - 5 to +50 | |
| Storage/transport [℃] | -20 to +70 | ||
| Material of housing | Die-cast aluminium | ||
| Grid dimension [mm] | 50 | ||
| Dimensions (incl. interlinking block) W x L x H [mm] | 50 x 107 x 80 | ||
| Weight [g] | 280 | ||
| Part Number |
|---|
| CPX-FB6 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Housing Material | Max. Address Capacity Inputs (Byte) | Max. Address Capacity Outputs (Byte) | Protocol | Configuration Support | Baud rate | Corrosion Resistance Class (CRC) | Manufacturer part # | Weight (g) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 3,688.36 | 1 Piece(s) | Quote | PA-reinforced, PC | 12 | 12 | INTERBUS® | - | 500, 2000 kbit/s | 1 - Low corrosion stress | 195748 | 125 |
Loading...
| Nominal DC Operating Voltage(V) | 24 | DC operating voltage range(V) | 18 - 30 | IP rating | IP65, IP67 |
|---|---|---|---|---|---|
| Min. Ambient Temperature(°C) | -5 | Max. Ambient temperature(°C) | 50 | Min. Storage Temperature(°C) | -20 |
| Max. Storage temperature(°C) | 70 |
Please check the type/dimensions/specifications of the part CPX-FB6 in the Bus node, CPX Series series.
| Part Number |
|---|
| CPX-FB11 |
| CPX-FB33 |
| CPX-FB37 |
| CPX-FB39 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Housing Material | Max. Address Capacity Inputs (Byte) | Max. Address Capacity Outputs (Byte) | Protocol | Configuration Support | Baud rate | Corrosion Resistance Class (CRC) | Manufacturer part # | Weight (g) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
MYR 3,688.36 | 1 Piece(s) | Quote | PC | 64 | 64 | DeviceNet | EDS file | 125, 250, 500 kbit/s | 1 - Low corrosion stress | 526172 | 120 | ||
MYR 5,335.16 | 1 Piece(s) | Quote | Die-cast aluminum | 64 | 64 | PROFINET IRT, PROFINET RT | GSDML file | 100 Mbit/s | 0 - No corrosion stress | 548755 | 280 | ||
MYR 6,329.82 | 1 Piece(s) | Quote | PC | 128 | 128 | EtherCAT | ESI file | 100 Mbit/s | 1 - Low corrosion stress | 2735960 | 125 | ||
MYR 6,329.82 | 1 Piece(s) | Quote | PA-reinforced | 64 | 64 | Sercos III | SDDML-document | 100 Mbit/s, full/half duplex | 1 - Low corrosion stress | 2093101 | 125 |
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy