Global standard cable, KMTW series (CE-KMTW-0.75SQ-R-300)

Global standard cable, KMTW series CE-KMTW-0.75SQ-R-300

Click this image to zoom it.

Move the mouse over the image to zoom

[Features]
· CE & UL/cUL & <PS>E (0.75 to 95 mm2) & TR-CU Global Standard Cable
· NFPA70, NFPA79 applicable (MTW, THW)
· Heat resistance
[Applications]
· For internal wiring of equipment and control panels

(i)Caution

  • [End of standard certification applicability] For this product, the TR-CU (Customs Union Technical Regulations), for which we had previously obtained certification, has become difficult to renew due to recent international circumstances. Although "EAC" is indicated in the manufacturer catalog, it is not applicable. Thank you for your understanding.
  • [Product Cross-Section Specification Change]
    Starting with production in September 2025, due to the manufacturer's equipment operations, both green-based and yellow-based cross-sectional color types of the following model will be mixed.
    Model: CE-KMTW-6SQ-GY
    However, there will be no change in the external appearance of the wire core (green 60: yellow 40), and there will be no impact on product performance or applicable standards. Thank you for your understanding.

PDF

Part Number

Configured Part Number is shown.

CE-KMTW-0.75SQ-R-300

Product Feature Details

Structural Overview

ItemsConfiguration
ConductorAnnealed copper wire
InsulatorHeat-resistant vinyl mixture
 

Compliant standards

CE: 05 V-K, 07 V-K
NFPA70, NFPA79 compliant

 

Technical Information & Design Ideas

Technical Data

Cable typeCEULcUL<PS>E
05 V-K07 V-KMTW AWMTHWAWMHKIV
Compatible size0.5 to 1 mm²1.5 to 150 mm²All sizes2.5 to 150 mm²
(14 AWG to 250 kcmil)
0.5 to 95 mm²
(20 to 3/0 AWG)
0.75 to 95 mm²
Rated voltage300/500 V450/750 V600V
Rated temperature70°C90°C DRY, 60°C WET75°C DRY and WET90°C75°C
Test voltage2,000 V AC/15 min2,500 V AC/15 min2,000 V AC/1 min^*1,500 V AC/1 min^*
Flame retardancyIEC 60332-1VW-1FT160° inclined
Compatible standardsAccording to EN 50525-2-31 (HD21.7)
According to VDE 0285-525-2-31 (VDE 0281-3)
UL 1063
UL 758
UL 83CSA C22.2
No. 210
Electrical Appliances and Materials Safety Act of Japan

* The test voltage differs depending on the size.

structure table

ConductorInsulationElectrical Characteristics
Nominal cross-sectional areaOuter diameter
(approx. mm)
[Configuration]
Outer diameter
(approx. mm)
Allowable
current value
(A)
Conductor resistance
20°C
(Ω/km)
Insulation Resistance
20°C
(MΩkm)
0.5 mm2
<20 AWG>
0.95
<22/0.18>
2.651134.6 or less50 or more
0.75 mm2
<18 AWG>
1.2
<35/0.18>
2.91521.8 or less50 or more
1 mm2
<18 AWG>
1.3
<40/0.18>
3.01619.5 or less50 or more
1.5 mm2
<16AWG>
1.6
<60/0.18>
3.32112.9 or less50 or more
2.5 mm2
<14AWG>
2.1
<50/0.25>
3.8287.98 or less40 or more
4 mm2
<12AWG>
2.6
<75/0.26>
4.6404.63 or less40 or more
6 mm2
<10AWG>
3.2
<114/0.26>
5.6543.08 or less30 or more
10 mm2
<8AWG>
4.3
<7/28/0.26>
7.1751.91 or less30 or more
16 mm2
<6AWG>
5.5
<7/28/0.32>
8.91041.20 or less20 or more
25 mm2
<4AWG>
7.3
<7/44/0.32>
10.71400.778 or less20 or more
35 mm2
<2AWG>
8.5
<19/23/0.32>
12.11780.533 or less20 or more
50 mm2
<1AWG>
10.1
<19/33/0.32>
14.72210.386 or less20 or more
70 mm2
<2/0 AWG>
12.2
<19/23/0.45>
16.82820.266 or less20 or more
95 mm2
<3/0AWG>
14.0
<19/31/0.45>
18.63450.194 or less20 or more
120 mm2
<4/0AWG>
16.4
<19/40/0.45>
21.03970.161 or less20 or more
150 mm2
"250 kcmil"
18.2
27/34/0.45
23.64260.129 or less20 or more

Product Properties

Operating temperature range

When fixed: -25 to 90°C*
*When using below 0°C, please ensure that no external forces such as impact, bending, or vibration are applied.

Bending radius

When fixed: Recommended at least 6 times the cable outer diameter

About allowable current

  • The allowable current value is the calculated value when the ambient temperature is 30°C and a single cable is laid in the air. It is not a guaranteed value.
  • For ambient temperatures above 30°C, multiply the values in the table by the following current reduction factors:
  • The allowable current value is a value calculated according to JCS0168 and is not a guaranteed value.
  • In Europe, there is a standard "IEC 60364-5-52" regarding the allowable current of wiring systems for electrical equipment in buildings. Please refer to it.
  • In the United States, allowable current values and temperature reduction factors are stipulated in the national electrical standard for industrial machinery (NFPA79), so please refer to them.

    JCS0168: The Japanese Electric Wire & Cable Makers' Association standard "Calculation of allowable current for power cable of 33 kV or less"

Current Reduction Factor Table

Ambient temperature (°C)3035404550556065
Current Reduction Factor1.000.940.870.790.710.610.50.35

Wire Core Identification

Wire Core Identification Method

Insulator coloring method: BK (black), W (white), R (red), BN (brown), BE (blue), O (orange), G/Y (green/yellow, straight), W/BE (white/blue, straight), W/O (white/orange, straight)

  • G/Y (green/yellow, straight): A yellow band is applied to the green wire core. (Color distribution Green 60: Yellow 40)
  • W/BE (white/blue, straight): A blue band is applied to the white wire core (Color distribution White 60: Blue 40)
  • W/O (white/orange, straight): An orange band is applied to the white wire core (Color distribution White 60: Orange 40)

Structure

Global standard cable, KMTW series, Structural drawing

Example: 0.75 mm² (18AWG)

Part Number
CE-KMTW-0.75SQ-R-300
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConductor Cross Section
(mm2)
AWG size 1
(AWG)
Sheath (outer coating) color Overall Length
(m)
Finished outer diameter
(mm)
Representative Standard AWG Size
(AWG)
Conductor Cross-Sectional Area
(mm2)
Insulator Color Total Length
(m)
Safety standard Overall Diameter
(mm)
Allowable Current
(A)
Conductor resistance
(20℃ Ω/㎞)
Insulation Resistance
(20°C MΩ km)
Conductor configuration Rated voltage 2 (CE)
(V)
Rated voltage 3 (PSE)
(V)

MYR 747.81

1 Piece(s) 12 Day(s) or more -18Red3002.9PSE / UL / CE / CSA(c-UL)[19 to 18] 180.75Red300UL Listed / CSA(c-UL) / PSE / CE2.91521.8 or less50 or more35/0.18300/500600

Loading...

  1. 1
 

Basic Information

Rated voltage 1 600V Properties 1 Heat-Resistance Shield 1 NA
Sheath (outer coating) material PVC (Polyvinyl Chloride) Type MTW Rated voltage 600V
Bobbin (Reel) Roll N/A Insulator Material PVC Upper Temperature Limit 90°C
Properties Heat Resistance Shield N/A Processing Service N/A
Note Rated voltage 1 is the rated voltage of UL/c-UL.

Please check the type/dimensions/specifications of the part CE-KMTW-0.75SQ-R-300 in the Global standard cable, KMTW series series.

Products like this...

Part Number
CE-KMTW-0.5SQ-GY-300
CE-KMTW-0.5SQ-O-300
CE-KMTW-0.5SQ-R-300
CE-KMTW-0.75SQ-W-300
CE-KMTW-0.75SQ-W/BE-300
CE-KMTW-0.75SQ-W/O-300
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConductor Cross Section
(mm2)
AWG size 1
(AWG)
Sheath (outer coating) color Overall Length
(m)
Finished outer diameter
(mm)
Representative Standard AWG Size
(AWG)
Conductor Cross-Sectional Area
(mm2)
Insulator Color Total Length
(m)
Safety standard Overall Diameter
(mm)
Allowable Current
(A)
Conductor resistance
(20℃ Ω/㎞)
Insulation Resistance
(20°C MΩ km)
Conductor configuration Rated voltage 2 (CE)
(V)
Rated voltage 3 (PSE)
(V)

MYR 602.25

1 Piece(s) 12 Day(s) or more -20Green/Yellow3002.65CSA(c-UL) / CE / UL[21 to 20] 200.5Green/Yellow (Straight)300CE / CSA(c-UL) / UL Listed2.651134.6 or less50 or more22/0.18300/500-

MYR 602.25

1 Piece(s) 13 Day(s) or more -20Orange3002.65CSA(c-UL) / CE / UL[21 to 20] 200.5Orange300CE / CSA(c-UL) / UL Listed2.651134.6 or less50 or more22/0.18300/500-

MYR 602.25

1 Piece(s) 12 Day(s) or more -20Red3002.65CSA(c-UL) / CE / UL[21 to 20] 200.5Red300CE / CSA(c-UL) / UL Listed2.651134.6 or less50 or more22/0.18300/500-

MYR 747.81

1 Piece(s) 13 Day(s) or more -18[Green] Green3002.9CSA(c-UL) / CE / UL / PSE[19 to 18] 180.75White300CE / PSE / CSA(c-UL) / UL Listed2.91521.8 or less50 or more35/0.18300/500600

MYR 747.81

1 Piece(s) 13 Day(s) or more -18[Green] Green/Yellow3002.9CSA(c-UL) / CE / UL / PSE[19 to 18] 180.75White/Blue (Straight)300CE / PSE / CSA(c-UL) / UL Listed2.91521.8 or less50 or more35/0.18300/500600

MYR 747.81

1 Piece(s) 13 Day(s) or more -18[White] White/Orange3002.9CSA(c-UL) / CE / UL / PSE[19 to 18] 180.75White/Orange (Straight)300CE / PSE / CSA(c-UL) / UL Listed2.91521.8 or less50 or more35/0.18300/500600

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)