(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

Global standard cable, CE-KIV series (CE-KIV-0.5SQ-R-300)

Global standard cable, CE-KIV series CE-KIV-0.5SQ-R-300

Click this image to zoom it.

Move the mouse over the image to zoom

[Features]
· CE & CCC & UL/cUL (6 mm2 or less) & GOST-R Global Standard Cable
· Heat resistance (105°C)
[Applications]
· For internal wiring of equipment

(i)Caution

  • [End of standard certification applicability] For this product, the TR-CU (Customs Union Technical Regulations), for which we had previously obtained certification, has become difficult to renew due to recent international circumstances. Although "EAC" is indicated in the manufacturer catalog, it is not applicable. Thank you for your understanding.
  • [Product Cross-Section Specification Change]
    Starting with production in September 2025, due to the manufacturer's equipment operations, both green-based and yellow-based cross-sectional color types of the following model will be mixed.
    Model: CE-KIV-6.0SQ-GY
    However, the external appearance of the wire core (green 60: yellow 40) will remain unchanged, and there will be no impact on product performance or applicable standards. Thank you for your understanding.

PDF

Part Number

Configured Part Number is shown.

CE-KIV-0.5SQ-R-300

Product Feature Details

Structural Overview

ItemsConfiguration
ConductorAnnealed copper wire
InsulatorHeat-resistant vinyl mixture
 

Compliant standards

CEH05V2-K (0.5 to 1.0 mm²) H07V2-K (1.5 to 35 mm²)
ULAWM 1007 (0.5 to 1 mm²) 1015 (1.5 to 6 mm²)
CCC227 IEC 06 (RV) (0.5 to 1 mm²)
227 IEC 02 (RV) (1.5 to 150 mm²)

Technical Information & Design Ideas

Technical Data

■0.5 (20) to 1 mm² (18AWG)

-CEUL/cULCCC
Cable typeH05V2-KAWM style 1007227 IEC 06 (RV)
Rated voltage300/500 V300V300/500 V
Rated temperature90°C80°C70°C
Test voltage2,000 V AC/15 min3,000 V AC/1 min2,000 V AC/5 min
Flame retardancyIEC 60332-1VW-1, FT1IEC 60332-1
Compatible standardsCENELEC HD 21.7 IEC 60227-3UL758 CSA C22.2 No. 210GB5023.3 IEC 60227-3
Compatible range0.5 to 1 mm²0.5 to 1 mm² (20 to 18AWG)0.5 to 1 mm²
 

■1.5 (16 AWG) to 150 mm²

-CEUL/cULCCC
Cable type1.5 to 35 mm²: H07V2-K
50 to 150 mm²: A07V2-K
AWM style 1015227 IEC 02 (RV)
Rated voltage450/750 V600V450/750 V
Rated temperature90°C105°C70°C
Test voltage2,500 V AC/15 min3,000 V AC/1 min2,500 V AC/5 min
Flame retardancyIEC 60332-1VW-1, FT1IEC 60332-1
Compatible standardsCENELEC HD 21.7 IEC 60227-3UL758 CSA C22.2 No. 210GB5023.3 IEC 60227-3
Compatible range1.5 to 150 mm²1.5 to 6 mm² (16 to 10AWG)1.5 to 150 mm²

Specifications Table

Overall Diameter / Approximate Weight Table

Nominal cross-sectional area (mm²) "AWG"
Number of conductor strands / diameter of conductor strands
Standard overall diameter (approx. mm)
Approximate weight (kg/km)
0.5  (22/0.18)
<20>
2.2
10
0.75 (30/0.18)
<19>
2.4
13
1 (40/0.18)
<18>
2.6
15
1.5  (60/0.18)
<16>
3.3
25
2.5 (50/0.25)
<14>
3.8
35
4  (75/0.26)
<12>
4.3
50
6 (112/0.26)
<10>
4.9
75
10  (7/28/0.26)6.4
125
16 (7/28/0.32)7.6
185
25  (7/44/0.32)9.8
300

Product Properties

Electrical Characteristics Table

Nominal Cross-Sectional Area (mm2)
(AWG)
Conductor resistance (20°C)
Ω/km or less
Insulation Resistance (20°C)
MΩkm or more
Allowable
current value
(A)
0.5 (20)39.05011
0.75 (19)26.05014
1 (18)19.55017
1.5 (16)13.35024
2.5 (14)7.984034
4 (12)4.954046
6 (10)3.303060
101.913087
161.2120119
250.78020164
  • The allowable current value is the calculated value when the ambient temperature is 30°C and a single cable is laid in the air.
    It is not a guaranteed value.
    For ambient temperatures above 30°C, multiply the values ​​in the table by the following current reduction factors:
  • The allowable current value is a value calculated according to JCS 197 and is not a guaranteed value.
    (In Europe, there is a standard for the allowable current of wiring systems for electrical equipment in buildings.
    Please refer to the standard, IEC 60364-5-52.
    JCS197···The Japanese Electric Wire & Cable Makers' Association standard, Allowable current of flexible cable)


 

Ambient Temperature Reduction Factor Table

Nominal Cross-Sectional Area (mm2)
(AWG)
Ambient temperature (°C)
303540455055606570758085
0.5 (20) to 1.0 (18)1.000.950.890.840.780.710.630.550.450.32Cannot be used because the temperature is higher than
the heat-resistant temperature of the cable
1.5 (16) to 1501.000.960.910.870.820.760.710.650.580.500.410.29

Wire Core Identification

Wire Core Identification Method

BK (black), W (white), R (red), BE (blue), O (orange), GY (green/yellow, straight)

  • GY (green/yellow, straight): Yellow straight line on green (Color distribution Green 60: Yellow 40)

Structure

Global standard cable, CE-KIV series, Structural drawing

Example: 0.5 mm² (20AWG)

Part Number
CE-KIV-0.5SQ-R-300
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConductor Cross Section
(mm2)
AWG size 1
(AWG)
Sheath (outer coating) color Rated voltage 1 Overall Length
(m)
Finished outer diameter
(mm)
Representative Standard Rated voltage AWG Size
(AWG)
Conductor Cross-Sectional Area
(mm2)
Insulator Color Total Length
(m)
Overall Diameter
(mm)
Allowable Current
(A)
Conductor resistance
(20℃ Ω/㎞)
Insulation Resistance
(20°C MΩ km)
Conductor configuration Rated voltage 2 (CE)
(V)
Rated voltage 4 (CCC)
(V)
Note

MYR 584.63

1 Piece(s) 13 Day(s) or more -20Red300V3002.2UL / CE / CSA(c-UL) / CCC300V[21 to 20] 200.5Red3002.21139.0 or less50 or more22/0.18300/500300/500Rated voltage 1 is the rated voltage of UL/c-UL.

Loading...

  1. 1
 

Basic Information

Properties 1 Heat-Resistance Shield 1 NA Sheath (outer coating) material PVC (Polyvinyl Chloride)
Type KIV Bobbin (Reel) Roll N/A Safety standard UL Recognized / CSA(c-UL) / CE / CCC
Insulator Material PVC Upper Temperature Limit 90°C Properties Heat Resistance
Shield N/A Processing Service N/A

Please check the type/dimensions/specifications of the part CE-KIV-0.5SQ-R-300 in the Global standard cable, CE-KIV series series.

Products like this...

Part Number
CE-KIV-0.5SQ-BE-300
CE-KIV-0.5SQ-BK-300
CE-KIV-0.5SQ-GY-300
CE-KIV-0.5SQ-W-300
CE-KIV-0.75SQ-BE-300
CE-KIV-0.75SQ-BK-300
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipConductor Cross Section
(mm2)
AWG size 1
(AWG)
Sheath (outer coating) color Rated voltage 1 Overall Length
(m)
Finished outer diameter
(mm)
Representative Standard Rated voltage AWG Size
(AWG)
Conductor Cross-Sectional Area
(mm2)
Insulator Color Total Length
(m)
Overall Diameter
(mm)
Allowable Current
(A)
Conductor resistance
(20℃ Ω/㎞)
Insulation Resistance
(20°C MΩ km)
Conductor configuration Rated voltage 2 (CE)
(V)
Rated voltage 4 (CCC)
(V)
Note

MYR 584.63

1 Piece(s) 13 Day(s) or more -20Blue300V3002.2CCC / CSA(c-UL) / CE / UL300V[21 to 20] 200.5Blue3002.21139.0 or less50 or more22/0.18300/500300/500Rated voltage 1 is the rated voltage of UL/c-UL.

MYR 584.63

1 Piece(s) 12 Day(s) or more -20Black300V3002.2CCC / CSA(c-UL) / CE / UL300V[21 to 20] 200.5Black3002.21139.0 or less50 or more22/0.18300/500300/500Rated voltage 1 is the rated voltage of UL/c-UL.

MYR 584.63

1 Piece(s) 13 Day(s) or more -20Green/Yellow300V3002.2CCC / CSA(c-UL) / CE / UL300V[21 to 20] 200.5Green/Yellow (Straight)3002.21139.0 or less50 or more22/0.18300/500300/500Rated voltage 1 is the rated voltage of UL/c-UL.

MYR 584.63

1 Piece(s) 12 Day(s) or more -20[Green] Green300V3002.2CCC / CSA(c-UL) / CE / UL300V[21 to 20] 200.5White3002.21139.0 or less50 or more22/0.18300/500300/500Rated voltage 1 is the rated voltage of UL/c-UL.

MYR 767.79

1 Piece(s) 13 Day(s) or more -19Blue300V3002.4CCC / CSA(c-UL) / CE / UL300V[19 to 18] 190.75Blue3002.41426.0 or less50 or more30/0.18300/500300/500Rated voltage 1 is the rated voltage of UL/c-UL.

MYR 767.79

1 Piece(s) 13 Day(s) or more -19Black300V3002.4CCC / CSA(c-UL) / CE / UL300V[19 to 18] 190.75Black3002.41426.0 or less50 or more30/0.18300/500300/500Rated voltage 1 is the rated voltage of UL/c-UL.

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)