(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
Solid state timer H3DK-G
[Features]
· DIN22.5 mm width standard timer series for use in the control panel.
· AC/DC free power source compatible (AC/DC24 to 240V).
· DC12V powered type has been added every series.
· UL, CSA, CCC acquired, EN61812-1 compatible. Compatible with the CE mark.
· Conforms with the EMC standard EN61812-1, so can be used in an industrial environment but also in residential, sales and light industry.
· A terminal construction with secure screw fittings that prevents against hazardous contact (EN50274 compliant).
Part Number
Configured Part Number is shown.
H3DK-G AC/DC24-240

External appearance of H3DK-G

Dimensional drawing of H3DK-G
(Unit: mm)
| Power Supply Voltage*1 | ·24 to 240 V AC/DC, 50/60 Hz*2 · 12 V DC *2 | |
|---|---|---|
| Allowable Voltage Fluctuation Range | ·AC/DC24 to 240 V: 85% to 110% of rated voltage ·12 V DC: 90% to 110% of rated voltage | |
| Power Supply Reset | Minimum power supply open time: 0.5 s | |
| Release voltage | 10% or less of rated voltage | |
| Power Consumption | Type H3DK-G | At 240 V AC: 6.6 VA or less*3 |
| Type H3DK-GA | At 12 V DC: 0.9 W or less | |
| Control output | Contact output (time limit [relay], 1c [circuit], 1c [△ circuit]): 250 V AC 5 A resistant load (cosø = 1), 30 V DC 5 A resistant load*4 125 V DC 0.15 A max.resistant load, 125 V DC 0.1 A max. L/R = 7 ms Minimum compatible load: 5 V DC 10 mA (P level, reference value) Contact materials: Ag alloy + Au plating | |
| Operating Temperature Range | -20 to +55°C (No freezing) | |
| Storage temperature range | -40 to +70°C (No freezing) | |
| Operating ambient humidity | 25 to 85% | |
| Variation in operating time | ±1% (percentage of maximum scale) or less | |
|---|---|---|
| Setting Error | ±10% (percentage of maximum scale) ±0.05 s or less | |
| Switching time | Total error ± (25% of switching time +5 ms) or less | |
| Influence of voltage | ±0.5% (percentage of maximum scale) or less | |
| Variation in temperature fluctuation | ±2% (percentage of maximum scale) or less | |
| Insulation Resistance | 100 MΩ or more with 500 V DC ohmmeter | |
| Withstand Voltage | 2,000 V AC, 50/60 Hz, 1 min (between the charging metal part and the non-charging metal part) 2,000 V AC, 50/60 Hz, 1 min (between the control output circuit and the operation circuit) 1,000 V AC, 50/60 Hz, 1 min (between the discontinuous contacts) | |
| Impulse voltage | ·AC/DC 24 to 240 V: 5 kV (between the power supply terminals), 5 kV (between the conductive terminal and the exposed non-charged metal part) ·12 V DC: 1 kV (between the power supply terminals), 1.5 kV (between the conductive terminal and the exposed non-charged metal part) | |
| Noise Resistance | Square wave noise by noise simulator (pulse width: 100 ns/1 µs, startup: 1 ns) ±1.5 kV | |
| Static electricity resistance | 4 kV (malfunction), 8 kV (destruction) | |
| Vibration | Durability | 10 to 55 Hz with 0.75-mm single amplitude each in 3 directions for 2 hours each |
| Malfunction | 10 to 55 Hz, 0.5-mm single amplitude, 3 directions, 10 min each | |
| Shock | Durability | 1,000 m/s^2, 6 directions, 3 cycles each |
| Malfunction | 100 m/s^2, 6 directions, 3 cycles each | |
| Lifespan | Mechanical | 10 million operations min. (under no load at 1,800 operations/h) |
| Electrical | 100,000 cycles or more (250 V AC 5 A resistant load, opening/closing frequency 360 cycles/h) | |
| Protective structure | IP30 (IP20 for terminals) | |
| Weight | Approx. 120 g | |
| Safety Standard | cURus: UL508/CSA C22.2 No. 14 EN50274: Finger protection, hand proof vertical only EN61812-1: contamination degree 2; overvoltage category III CCC: GB/T 14,048.5 pollution degree 2; overvoltage category III * LR: Test Specification No. 1-2002 category ENV1.2 | |
|---|---|---|
| EMC | (EMI) Radiated Emissions Conducted Emissions Harmonic current Voltage fluctuation, flicker (EMS) Electrostatic discharge immunity Electric field strength immunity Burst noise immunity Surge immunity Conductive noise immunity Voltage dip / power interruption immunity | EN61812-1 EN55011 class B EN55011 class B EN61000-3-2 EN61000-3-3 EN61812-1 IEC61000-4-2 IEC61000-4-3 IEC61000-4-4 IEC61000-4-5 IEC61000-4-6 IEC61000-4-11 |
| Recommended fuse | 0216005 (250 V AC, 5 A) made by Littelfuse |
|---|---|
| Rated operating voltage Ue Rated operating current Ie | AC-15: Ue: 250 V AC, Ie: 3 A AC-13: Ue: 250 V AC, Ie: 5 A DC-13: Ue: 30 V DC, Ie: 0.1 A |
| Rated Insulation Voltage | 250 V |
| Rated impulse voltage (altitude: up to 2,000 m) | 4 kV (at 240 V AC) |
| Conditional short circuit current | 1,000 A |
See the figure below for the relationship between the mounting interval and the load current.
Note that using the timer under higher load conditions may shorten the lifespan of internal components due to temperature rise inside the timer.
Test method

Relationship between the mounting interval and the load current

Test method image

Internal connection diagram of H3DK-G

Terminal layout of H3DK-G
* The power supply terminal has no polarity.

Front view of H3DK-G

Bottom view of H3DK-G

For single wires of 2.5 mm^2 or less

For bar terminals with insulation sleeves
| Part Number |
|---|
| H3DK-G AC/DC24-240 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship |
|---|---|---|---|---|
MYR 391.62 | 1 Piece(s) | 5 Day(s) or more |
Loading...
| Type | Time switch | Display Method | Analog | Mounting Method | DIN rail mount |
|---|---|---|---|---|---|
| Time Specifications(s) | 1s to 120s | Power Supply Voltage | AC/DC | Output Method | Relay |
| Representative Standard | CE / UL / CCC / CSA | Dimension Vertical(mm) | 89.4 | Dimension Width(mm) | 22.5 |
| Dimension Depth(mm) | 100 | Rated Power Supply Voltage(V) | 24–240 VAC/VDC, 12 VDC | Time Ranges = N | 2 range |
| Contact Configuration | 1c |
Please check the type/dimensions/specifications of the part H3DK-G AC/DC24-240 in the Solid State/Timer H3DK-G series.



A&D
Standard Price : MYR 4,099.25
Days to Ship : 5 Day(s) or more
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy