(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
A low-profile power relay with a height of just 15.7 mm, enabling it to be incorporated into small-sized equipment.
[Features]
· 1-pole, 2-pole and high-capacity types are available.
· High sensitivity with a power consumption of 400 mW.
· A highly insulated type with an impact withstand voltage of 10 kV and a minimum 8 mm insulation distance between the coil and contacts.
· Ambient operating temperature of -40 to 85°C.
· Complies with VDE standards as standard.
[Applications]
· For PCBs used in communications equipment, OA equipment, testing instruments, disaster/crime-prevention devices, security devices, etc.
Part Number
Configured Part Number is shown.

G2RL external appearance

G2RL-1 composition

G2RL-1 dimensional drawing, Units: mm
*Average dimensions.

G2RL-1 PCB processing dimensional drawing

G2RL-1 terminal layout/schematics
There is no coil polarity.

G2RL-1A-E composition

G2RL-1A-E dimensional drawing, Units: mm
*Average dimensions.

G2RL-1A-E PCB processing dimensional drawing

G2RL-1A-E terminal layout/schematics
There is no coil polarity.

Reference data: Ambient temperature and maximum allowable voltage
Note: The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.
| Classification | Standard Type | High Capacity Type | |||
|---|---|---|---|---|---|
| Number of Contacts | 1 Pole | 2 Pole | 1 Pole | ||
| Items | Contact Resistance *1 | 100 mΩ or Less | |||
| Turn-ON Time | 15 ms or Less | ||||
| Turn-OFF Time | 5 ms or Less | ||||
| Maximum Switching Frequency | Mechanical | 18,000 Times/h | |||
| Rated Load | 1,800 Times/h | ||||
| Insulation Resistance *2 | 1,000 MΩ or More | ||||
| Withstand Voltage | Between Coil and Contact | 5,000 V AC 50/60 Hz 1 min | |||
| Between Contacts of Same Polarity | 1,000 V AC 50/60 Hz 1 min | ||||
| Between Contacts of Different Polarities | - | 2,500 V AC 50/60 Hz 1 min | - | ||
| Insulation Distance | Between Coil and Contact | Space: 8 mm, Creepage: 8 mm | |||
| Impulse Withstand Voltage | 10 kV (1.2 × 50 μs) | ||||
| Vibration | Durability | 10 to 55 to 10 Hz, Semi Amplitude 0.75 mm (Double Amplitude 1.5 mm) | |||
| Malfunction | 10 to 55 to 10 Hz, Semi Amplitude 0.75 mm (Double Amplitude 1.5 mm) | ||||
| Shock / Impact | Durability | 1,000 m/s2 | |||
| Malfunction | Energized: 100 m/s2, Non-Energized: 100 m/s2 | ||||
| Durability | Mechanical | 20,000,000 Times or More (Switching Frequency: 18,000 Times/h) | |||
| Electrical *3 (Resistance Load) | Model: G2RL-1A : 250 V AC 10 A, 100,000 Times : 24 V DC 10 A, 30,000 Times Model G2RL-1 : 250 V AC 10 A, 50,000 Times : 24 V DC 10 A, 30,000 Times | Model: G2RL-2A : 250 V AC 5 A, 100,000 Times : 24 V DC 5 A, 30,000 Times Model G2RL-2 : 250 V AC 5 A, 50,000 Times : 24 V DC 5 A, 30,000 Times | Model: G2RL-1A-E(-ASI) : 250 V AC 16 A, 50,000 Times : 24 V DC 16 A, 30,000 Times Model G2RL-1-E : 250 V AC 16 A, 30,000 Times : 24 V DC 16 A, 30,000 Times | ||
| Ambient Operating Temperature | -40 to +85°C (Assuming No Freezing or Condensation) | ||||
| Operating Ambient Humidity | 5 to 85% RH | ||||
| Weight | Approx. 12 g | ||||
Note: The above values are the initial default values.
| Part Number |
|---|
| G2RL-1A-E DC24 |
| G2RL-2 DC24 |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | Contact Configuration | Contact Rated Current (Minimum Value for AC and DC) (A) (A) | Classification |
|---|---|---|---|---|---|---|---|
MYR 22.38 | 1 Piece(s) | 2 Day(s) | 1a | 16 | High Capacity Type | ||
MYR 23.95 | 1 Piece(s) | 2 Day(s) | 2c | 5 | Standard Type |
Loading...
| Application | Power | Latch Function | NA | Terminal Shape | For Circuit Boards |
|---|---|---|---|---|---|
| Coil Rated Voltage (DC)(V) | 24 | Representative Standard | UL / CSA | Dimension Height(mm) | 15.7 |
| Dimension Width(mm) | 29 | Dimension Depth(mm) | 12.7 | Contact Mechanism | Single |
| Protective Structure | Flux resistant shape |










How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy