Temperature Adjustment Unit (MELSEC-Q Series)

Temperature Adjustment Unit (MELSEC-Q Series)
  • On Sale Till 30/06/2026

A temperature adjustment unit for the versatile MELSEC-Q series

PDF

Part Number

Configured Part Number is shown.

Q64TCRTN

Temperature Control Unit (MELSEC-Q Series) Specifications

Temperature control unit (MELSEC-Q Series) image

Temperature control unit (MELSEC-Q Series) image

Control OutputTransistor output
Number of Temperature Input Points4 channels / unit
Compatible Resistance Temperature DetectorPt100, JPt100
AccuracyIndication AccuracyAmbient Temperature: 25±5°CFull scale×(±0.3%)
Ambient Temperature: 0 to 55°CFull scale×(±0.7%)
Sampling Cycle500 ms / 4 channels
Control Output Period1 to 100 s
Input Impedance1 MΩ
Input Filter0 to 100 s (0: input filter OFF)
Setting of Sensor Correction Value-50.00 to 50.00%
Operation in Case of Sensor Input DisconnectionUpscale processing
Temperature Control SystemPID ON/OFF pulse or 2-position control
PID Constant RangePID Constant SettingSetting by auto-tuning is possible
Proportional Band (P)0.0 to 1,000.0% (0.0: 2-position control)
Integral Time (I)0 to 3,600 s (0: P control, PD control)
Derivative Time (D)0 to 3,600 s (0: P control, PI control)
Target Value Setting RangeWithin the temperature range set by the platinum temperature-sensing resistance used
Dead Zone Setting Range0.1 to 10.0%
Transistor OutputOutput SignalON/OFF Pulse
Rated Load Voltage10 to 30 V DC
Maximum Load Current0.1 A / 1 point, 0.4 A / 1 common
Maximum Inrush Current0.4 A, 10 ms
Leakage Current When OFF0.1 mA or less
Maximum Voltage Drop When ON1.0 V DC (TYP.) at 0.1 A, 2.5 V DC (MAX.) at 0.1 A
Response TimeOFF→ON2 ms or less
ON→OFF2 ms or less
Insulation MethodBetween input terminal and sequencer power supply, between input channels: transformer insulation
Dielectric StrengthBetween input terminal and sequencer power supply, between input channels: 500 V AC for 1 min
Insulation ResistanceBetween input terminal and sequencer power supply, between input channels: 500 V DC 20 MΩor more
External Wiring Connection Method18-point screw terminal block (M3 screw)
Number of Occupied Inputs/Outputs16 points (I/O assignment: intelligent 16 points)
5 V DC Internal Current Consumption0.29 A
External DimensionsHeight (H)98 mm
Width (W)27.4 mm
Depth (D)112 mm
Weight0.20 kg
Part Number
Q64TCRTN
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

MYR 3,570.00

MYR 2,856.00

1 Piece(s) 79 Day(s)

Loading...

  1. 1
 

Basic Information

Type Temperature control Number of Input Points (Number of Input CH) 4 Input I/F (Input Target) Temperature Measuring Resistor
Connection Terminal Terminal Block Representative Standard CE / UL / CUL Applicable sequencer MELSEC-Q Series
Temperature Control System PID ON/OFF Pulse or Dual Position Control Heater Burnout Detection Function NA

Please check the type/dimensions/specifications of the part Q64TCRTN in the Temperature Adjustment Unit (MELSEC-Q Series) series.

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)