Surface-mount Relay - G6L

Surface-mount Relay - G6L

[Features]
· An ultra-thin single pole flat relay with the lowest profile in its class.
· Requires approximately 20% less surface area for mounting and has approximately 64% the volume (compared to the manufacturer's G5V-1). This enables high-density mounting (width: 7.0 mm × length: 10.6 mm × height: 4.5 mm (SMD), 4.1 mm (TH)).
· High withstand voltage between coil-contacts of AC1,000V. Also boasts impulse voltage resistance of 1.5kV10 × 160 μs (FCCPart68 compliant).
· High withstand voltage between identical polarity contacts of 750V.
· Surface mounted types also available.
· The standard type is UL and CSA standard certified.
· Uses absolutely no lead.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

G6L-1P DC5

Surface Mount Relay G6L Series Specifications

Surface Mount Relay G6L: related images

Model G6L-1P outline drawing

Surface Mount Relay G6L: related images

Note: The general dimensional tolerance is ±0.3 mm.

Surface Mount Relay G6L: related images

The dimensional tolerance is ±0.1 mm.

Ratings

ItemsRated Current
(mA)
Coil Resistance
(Ω)
Operating Voltage
(V)
Release Voltage
(V)
Maximum Allowable Voltage
(V)
Power Consumption
(mW)
Rated Voltage (V)
DC536.0139.075% or Less10% or More150%Approx. 180
1215.0800.0

Note 1: The rated current and coil resistance are measured at a coil temperature of +23°C and a tolerance of ±10%.
Note 2: The operating characteristics are measured at a coil temperature of +23°C.
Note 3: The maximum allowable voltage is the maximum voltage that can be applied to a relay coil.
Note 4: Measurements for Turn ON/Turn OFF voltage are values measured using instantaneous changes in voltage (rectangular waves).

Performance

TypeSingle Stable Type
ModelModel G6L-1P
Contact Resistance *1100 mΩ or Less
Operating Time *25 ms or Less (Approx. 1.1 ms)
Turn OFF Time *25 ms or Less (Approx. 0.4 ms)
Insulation Resistance *31,000 MΩ or More (at 500 V DC)
Withstand VoltageBetween Coil and Contact1,000 V AC 50/60 Hz 1 min
Between Contacts of Same Polarity750 V AC 50/60 Hz 1 min
Impulse Withstand VoltageBetween Coil and Contact1,500 V 10 × 160 μs
VibrationDurability10 to 55 Hz Semi-Amplitude 1.65 mm (Double Amplitude 3.3 mm)
Malfunction10 to 55 Hz Semi-Amplitude 1.65 mm (Double Amplitude 3.3 mm)
Shock / ImpactDurability1,000 m/s2
Malfunction100 m/s2
DurabilityMechanical5,000,000 Times or More (Switching Frequency: 36,000 Times/h)
Electrical100,000 Times or More (Rated Load, Switching Frequency: 1,800 Times/h)
Failure Rate P Level (Reference Value *4)5 V DC, 1 mA
Ambient Operating Temperature-40 to +70°C (Assuming No Freezing or Condensation)
Operating Ambient Humidity5 to 85%RH
WeightApprox. 0.6 g

Note: The above values are the initial default values.
*1. Measurement conditions: 1 V DC 10 mA, voltage drop method.
*2. The values within ( ) are the actual values.
*3. Measurement conditions: Measuring the same spot for the withstand voltage items using a 500 V DC insulation resistance meter.
*4. This value is obtained with a switching frequency of 120 times/min. and a contact resistance failure value of 100 Ω.
These values may vary depending on switching frequency and operating conditions, meaning it is always recommended to double-check under actual load conditions.

  • *Refer to the catalog for other specifications.
Part Number
G6L-1P DC5
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to Ship

MYR 20.05

1 Piece(s) 2 Day(s)

Loading...

  1. 1
 

Basic Information

Application For Signals Contact Configuration 1a Latch Function NA
Terminal Shape For Circuit Boards Contact Rated Current (Minimum Value for AC and DC)(A) 0.3 Coil Rated Voltage (DC)(V) 5
Dimension Height(mm) 4.1 Dimension Width(mm) 10.6 Dimension Depth(mm) 7
Classification Single stable shape Protective Structure Plastic seal type Contact Mechanism Crossbar twin
Circuit Board Mounting Circuit board hole insertion AC Rated Load(V)/(A) AC125/0.3 DC Rated Load(V)/(A) DC24/1
Terminal Shape Through-hole

Please check the type/dimensions/specifications of the part G6L-1P DC5 in the Surface-mount Relay - G6L series.

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)