(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • [Notice] Japan & China Golden Week holidays will start from 29 April to 6 May 2026. Kindly expect longer response from suppliers and possible delivery delay due to high volume of shipments after holiday. Early order placement is recommended. More details
  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

Control Panel Fan Unit (C-EMU1238-SSCG-2)

Control Panel Fan Unit C-EMU1238-SSCG-2

A control panel fan unit that integrates a fan and peripheral devices.
[Features]
・ Easy selection, installation and maintenance due to integrated structure
・ Achieves measures against heat management in the panel, dust-proof and drip-proof. Realizing a comfortable environment for precision equipment in the panel
・ Early detection of cooling abnormalities with alarm products. Achieves a longer device lifespan
・ More effective control panel cooling with fan temperature switch
・ Since the characteristics are clear when the finger guard, filter, cover, etc., are attached, selection work can be saved
・ The cover is removable from the outside, so you can easily replace the filter media
・ The cover of the finger guard unit IP2X can be removed with single-action
[Applications]
・ Ideal for cooling control panels

PDF

Japanese Only

Part Number

Configured Part Number is shown.

C-EMU1238-SSCG-2

 
Part Number
C-EMU1238-SSCG-2
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Size Thickness Input Voltage Sensor output Properties Representative Standard Maximum Air Flow (AC Input Voltage, when 50 Hz)
(m3/min)
Maximum Air Flow (AC Input Voltage, when 60Hz)
(m3/min)
Maximum air flow (DC input voltage)
(m3/min)
Volume (AC input voltage, 50 Hz)
(dB)
Volume (AC input voltage, 60Hz)
(dB)
Volume (DC input voltage)
(dB)
Maximum Static Pressure (AC Input Voltage, 50 Hz)
(Pa)
Maximum Static Pressure (AC Input Voltage, 60Hz)
(Pa)
Maximum static pressure (DC input voltage)
(Pa)
Type Protection Grade Connection Type Additional Function Alarm output format Panel Color Cooling form External Dimensions
(mm)
Mounted fan size Number of mounted fans
(Units)
Output state Input voltage details Finger Guard

MYR 739.64

1 Piece(s) 17 Day(s) or more AC fan120x12038mm[Other] Three-phase 200 VNAStandard (general purpose)CE / UL / CSA1.21.2-4545-5353-Slit Sheet Metal UnitIP4XPlug cord for power supply connection (2 m)None-CreamIntake Type180 × 180-1-Single Phase 100 to 240 VFinger Guard Assembly

Loading...

  1. 1

Please check the type/dimensions/specifications of the part C-EMU1238-SSCG-2 in the Control Panel Fan Unit series.

Products like this...

Part Number
C-EMU1238-SECG-2
C-EMU1238-SEG-1
C-EMU1238-SEG-2
C-EMU1238-SSG-2
C-EMU1238M-GSFBG-2
C-EMU1238M-SE2G-1
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipType Size Thickness Input Voltage Sensor output Properties Representative Standard Maximum Air Flow (AC Input Voltage, when 50 Hz)
(m3/min)
Maximum Air Flow (AC Input Voltage, when 60Hz)
(m3/min)
Maximum air flow (DC input voltage)
(m3/min)
Volume (AC input voltage, 50 Hz)
(dB)
Volume (AC input voltage, 60Hz)
(dB)
Volume (DC input voltage)
(dB)
Maximum Static Pressure (AC Input Voltage, 50 Hz)
(Pa)
Maximum Static Pressure (AC Input Voltage, 60Hz)
(Pa)
Maximum static pressure (DC input voltage)
(Pa)
Type Protection Grade Connection Type Additional Function Alarm output format Panel Color Cooling form External Dimensions
(mm)
Mounted fan size Number of mounted fans
(Units)
Output state Input voltage details Finger Guard

MYR 739.64

1 Piece(s) 17 Day(s) or more AC fan120x12038mm[Other] Three-phase 200 VNAStandard (general purpose)CE / UL / CSA1.11.1-4747-6969-Slit Sheet Metal UnitIP4XPlug cord for power supply connection (2 m)None-CreamDischarge Type180 × 180-1-Single Phase 100 to 240 VFinger Guard Assembly

MYR 738.65

1 Piece(s) 17 Day(s) or more AC fan120x12038mm[Other] Three-phase 200 VNAStandard (general purpose)CE / UL / CSA1.11.1-4747-6969-Slit Sheet Metal UnitIP4XPlug cord for power supply connection (1 m)None-BeigeDischarge Type180 × 180-1-Single Phase 100 to 240 VFinger Guard Assembly

MYR 739.64

1 Piece(s) 17 Day(s) or more AC fan120x12038mm[Other] Three-phase 200 VNAStandard (general purpose)CE / UL / CSA1.11.1-4747-6969-Slit Sheet Metal UnitIP4XPlug cord for power supply connection (2 m)None-BeigeDischarge Type180 × 180-1-Single Phase 100 to 240 VFinger Guard Assembly

MYR 739.64

1 Piece(s) 17 Day(s) or more AC fan120x12038mm[Other] Three-phase 200 VNAStandard (general purpose)CE / UL / CSA1.21.2-4545-5353-Slit Sheet Metal UnitIP4XPlug cord for power supply connection (2 m)None-BeigeIntake Type180 × 180-1-Single Phase 100 to 240 VFinger Guard Assembly

MYR 525.21

1 Piece(s) 17 Day(s) or more AC fan120x12038mm[Other] Three-phase 200 VNAStandard (general purpose)CE / UL / CSA22-4343-7373-Finger Guard Unit (with Filter)IP2XPlug cord for power supply connection (2 m)Decreased rotational speed alarm (non-contact type)Open-collector outputBeigeIntake Type161 × 158-1During normal rotation: L level (internal transistor ON), during alarm output: H level (internal transistor OFF)Single Phase 100 to 240 VFinger Guard Assembly

MYR 1,432.78

1 Piece(s) 17 Day(s) or more AC fan120x12038mm[Other] Three-phase 200 VNAStandard (general purpose)CE / UL / CSA-2.3-5050-7575-Slit Sheet Metal UnitIP4XPlug cord for power supply connection (1 m)Decreased rotational speed alarm (non-contact type)Open-collector outputBeigeDischarge Type305 × 180-2During normal rotation: L level (internal transistor ON), during alarm output: H level (internal transistor OFF)Single Phase 100 to 240 VFinger Guard Assembly

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)