A cable made of bare soft copper stranded wire insulated with heat resistant PVC. Single-core vinyl insulated cable obtained under multiple standards in North America, Europe and Japan.
[Features]
· Multi-standard cable certified under UL1015 + MTW of North America, H07 V2K of Europe, and HKIV of Japan.
· A high safety product with excellent heat resistance and vertical flame retardance
· Compatible with the HD standard of Europe, UL standard of the US, cUL standard of Canada and HKIV and 60227IEC02 of Japan.
· This product is compatible with "UL Traceability Program / Processed Wires."
[Applications]
· Can be used for internal wiring of semiconductor manufacturing equipment and other equipment mainly for export
· For internal wiring of equipment

(i)Caution

  • The product image is a representative image. Specifications may vary by part number, including shape and color.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

MTW-0.5SQ-BE-100

The delivery specifications for this product are available here

Dimensional Drawing and Product Specifications

A ULCE-KIV composite standard cable

A ULCE-KIV composite standard cable.

3 green lines and 3 yellow lines, for grounding.

GY (green/yellow, straight), 3 lines for grounding.

Product Classification

Product nameProduct ClassificationRemarks
A ULCE-KIV composite standard cable
(Cable for internal wiring of electrical devices)
MTW+AWM 1015+AWM I A/BMTW: UL
AWM 1015: UL
AWM I A/B: CSA
MTW+AWM 1015+AWM I A/B+HKIVMTW: UL
AWM 1015: UL
AWM I A/B: CSA
HKIV: <PS>E
H07 V2-K+MTW+AWM 1015
+AWM I A/B+60227 IEC 02
H07 V2-K: CENELEC HD
MTW: UL
AWM 1015: UL
AWM I A/B: CSA
60227 IEC 02: <PS>E

Product Specifications

Product ClassificationCross-sectional areaApplicable StandardsRatingFlame retardancy
VoltageTemperature
MTW+AWM 1015+AWM I A/B0.5 mm2 (20 AWG)UL 1063 MTW600V90°C DRY
60°C WET
VW-1
UL 758 AWM 1015600 V AC or 750 V DC105°CVW-1
CSA-C22.2 No.210600V105°CFT-1
MTW+AWM 1015+AWM I A/B+HKIV0.75 mm2 (18 AWG)
1.0 mm2 (18 AWG)
UL 1063 MTW600V90°C DRY
60°C WET
VW-1
UL 758 AWM 1015600 V AC or 750 V DC105°CVW-1
CSA-C22.2 No.210600V105°CFT-1
<PS>E600V75°C- F-
H07 V2-K+MTW+AWM 1015
+AWM I A/B+60227 IEC 02
1.5 mm2 (16 AWG)
2.5 mm2 (14 AWG)
4.0 mm2 (12 AWG)
6.0 mm2 (10 AWG)
CENELEC HD 21.7
IEC 60227
450 V/750 V90°CIEC60332-1
UL 1063 MTW600V90°C DRY
60°C WET
VW-1
UL 758 AWM 1015600 V AC or 750 V DC105°CVW-1
CSA-C22.2 No.210600V105°CFT-1
<PS>E J60227450 V/750 V70°C- F-
J60332-1

structure table

Part numberCross-sectional area
(mm2)
ColorSales LengthApplicable standards
(Applicable)
ConductorOverall
diameter
(mm)
Conductor
Resistance
(20°C)
Ω/km
Insulation
Resistance
MΩkm or more
Insulation
resistor
temperature
conditions
Withstand voltage
V/15 min
Allowable
current
A (30°C)
Approximate
Weight
(kg/km)
1 roll
(m)
Overall length
(m)
UL
MTW
UL
AWM
PSE
600V
cUL
600V
CE
600V
Configuration
(pcs./mm)
Outer diameter
(mm)
MTW0.5* (20 AWG)BK (Black), R (Red)
W (White), BE (Blue)
Y (Yellow), O (Orange)
GY(Green/Yellow, Straight)
30510, 50, 100ApplicableApplicable Applicable 21/0.181.02.730.10 or less--20001512
0.75 * (18 AWG)ApplicableApplicableApplicableApplicable 34/0.181.22.921.80 or less0.05
(50)
75°C
(20°C)
25001916
1.0* (18 AWG)ApplicableApplicableApplicableApplicable 40/0.181.33.019.50 or less1918
1.5* (16 AWG)15310, 50ApplicableApplicableApplicableApplicableApplicable60/0.181.63.313.30 or less0.01070°C2722
2.5* (14 AWG)107ApplicableApplicableApplicableApplicableApplicable47/0.262.13.87.98 or less0.0093734
4.0* (12 AWG)BK (Black), R (Red)
GY(Green/Yellow, Straight)
ApplicableApplicableApplicableApplicableApplicable76/0.262.64.34.95 or less0.0075052
6.0* (10 AWG)ApplicableApplicableApplicableApplicableApplicable112/0.263.24.93.30 or less0.0066574

*(AWG--) is only a reference for AWG sizes.
*GY (green/yellow, straight) is a green wire core with a yellow band (approximately 30% retention).
*For the outer diameter size of the cable/wire sheath (outer sheath), please refer to the "overall diameter" item in the table above.

 

Operating temperature range-15 to 105°C
Certified standardsULMTW
Bending radius8 times the overall diameter (fixed part)

Structural drawing

MTW, UL Listed applicable: Related images

Current Reduction Factor

■ MTW standard 90°C dry criteria

Ambient temperature (°C)304050607080
Current Reduction Factor1.000.910.820.710.580.41


■ MTW standard 60°C wet criteria

Ambient temperature (°C)304050
Current Reduction Factor1.000.820.58

The allowable current is a calculated value at an ambient temperature of 30°C with a single cable in the air, and is not a guaranteed value.
If the ambient temperature is 30°C or higher, multiply the allowable current by the above current reduction factor.
(Example) Allowable current value for 0.5 mm2 at an ambient temperature of 40°C in a dry state
  11 x 0.91 = 10.01 (A)

Part Number
MTW-0.5SQ-BE-100
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipAWG Size
(AWG)
Conductor Cross-Sectional Area
(mm2)
Insulator Color Total Length
(m)
Safety standard Overall Diameter
(mm)
Number of strands/strands
(Units/mm)
Conductor outer diameter
(mm)
Conductor resistance
(Ω/km or less)

MYR 403.81

1 Piece(s) 10 Day(s) or more [21 to 20] 200.5Blue100UL Listed / CSA(c-UL)2.721/0.18130.10

Loading...

  1. 1
 

Basic Information

Type MTW Rated voltage 600V Bobbin (Reel) Roll N/A
Insulator Material PVC Upper Temperature Limit 105°C Properties Heat Resistance
Shield N/A Processing Service N/A Insulation body thickness(mm) 0.85
Flame Retardant VW-1

Please check the type/dimensions/specifications of the part MTW-0.5SQ-BE-100 in the Cable for European/North American Standard Supported Equipment series.

Products like this...

Part Number
MTW-0.5SQ-BE-10
MTW-0.5SQ-BE-305
MTW-0.5SQ-BE-50
MTW-0.5SQ-BK-10
MTW-0.5SQ-BK-100
MTW-0.5SQ-BK-305
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipAWG Size
(AWG)
Conductor Cross-Sectional Area
(mm2)
Insulator Color Total Length
(m)
Safety standard Overall Diameter
(mm)
Number of strands/strands
(Units/mm)
Conductor outer diameter
(mm)
Conductor resistance
(Ω/km or less)

MYR 137.34

1 Piece(s) 10 Day(s) or more [21 to 20] 200.5Blue10CSA(c-UL) / UL Listed2.721/0.18130.10

MYR 518.80

1 Piece(s) 10 Day(s) or more [21 to 20] 200.5Blue305CSA(c-UL) / UL Listed2.721/0.18130.10

MYR 206.00

1 Piece(s) 10 Day(s) or more [21 to 20] 200.5Blue50CSA(c-UL) / UL Listed2.721/0.18130.10

MYR 137.34

1 Piece(s) 10 Day(s) or more [21 to 20] 200.5Black10CSA(c-UL) / UL Listed2.721/0.18130.10

MYR 403.81

1 Piece(s) 10 Day(s) or more [21 to 20] 200.5Black100CSA(c-UL) / UL Listed2.721/0.18130.10

MYR 418.85

1 Piece(s) 10 Day(s) or more [21 to 20] 200.5Black305CSA(c-UL) / UL Listed2.721/0.18130.10