(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

MS-N Series electromagnetic contactor, main circuit B contact type (B-T21 AC200V 3B)

MS-N Series electromagnetic contactor, main circuit B contact type B-T21 AC200V 3B

Electromagnetic contactor for Mitsubishi electromagnetic switch.
[Features]
· Main contact is b contact (always closed contact)
· Types are AC operation B-N type and DC operation BD-N type.
[Applications]
· For motor startup resistance short-circuit, and for AC motor soft start.
· For regenerative power generation (dynamic brake) and for electric light circuit AC/DC power switching.

PDF

Part Number

Configured Part Number is shown.

B-T21 AC200V 3B

MS-N Series Main Circuit B Contact Type AC Operation Type Electromagnetic Contactor Features

  • External dimensions and mounting surface area are greatly decreased compared to the conventional product, making for a small size and saving space.
  • Uses AC operation DC excitation method electromagnet.
  • Fully prevents noise.
  • Wide shared rated coil (nominal 200 V AC: rated 200 to 240 V AC 50/60 Hz).
  • Built-in surge absorbing function.
  • Greatly reduced power consumption.
  • Can be used with live part protection cover UN-CV / CZ□ type.
  • Twin contacts with high contact reliability are used as the auxiliary contact, and are applicable to a 20 V 5 mA load.
  • The material name used is displayed on major plastic parts, improving environmental compliance.
  • Main circuit inter-phase barrier is standard equipment, which improves safety.

MS-N Series Main Circuit B Contact Type AC Operation Type Electromagnetic Contactor Specifications

Rating / Performance

Operation MethodType NameMain Contact ConfigurationDC Rated Operating Current [A]Open Thermal Current
Ith[A]
Auxiliary Contact Configuration
DC Motor Load
(DC2, DC4 Class)
DC Resistance Load
(DC1 Class)
100 V To 110 V200 V To 220 V100 V To 110 V200 V To 220 V
AC OperationB-N201a2b, 3b8 (15)1 (5)15 (20)5 (10)252a
B-N6520 (50)3 (20)30 (65)10 (30)802a2b
B-N1001a2b3034020120
DC OperationBD-N201a2b81155252a
BD-N652033010802a2b
BD-N1003034020120
  • Note 1: DC rating is for when a 2-contact in-line is used. The value in ( ) is for when a 3-contact in-line is used.
  • Note 2: Electrical durability 500,000 times, mechanical durability 5,000,000 times, switching frequency 1,200 times/hour.
  • Note 3: When applying main circuit contact to AC, you can use the table below.
Operation MethodType NameMain Contact ConfigurationAC Rated Operating Current [A]
b-Contacta-Contact
Three-Phase2-Contact In-Line Single-Phase1-Contact Single-Phase1-Contact Single-Phase
200 V To 220 V380 V To 440 V200 V To 220 V200 V To 220 V200 V To 220 V
AC OperationB-N201a2b, 3b1813181818
B-N655035505050
B-N1001a2b8055808080
DC OperationBD-N201a2b1813181818
BD-N655035505050
BD-N1008055808080
 Closing, interruption role conditions / switching durabilityClosing only, no break / 500,000 timesClosing, break 500,000 timesClosing only, no break / 500,000 timesClosing, break 500,000 times

Note 1. Switching durability is the value when switching closing rated operating current × 6, or break rated operating current × 1, or when switching without interruption.

Characteristics

Type NameInput [VA]Power Consumption
[W]
Operating Voltage [V]Coil Current
[mA]
Operating Time [ms]
InstantaneousConstantOperationOpenCoil ON → Main b OFFCoil OFF → Main b ON
B-N2090154.0125 to 15575 to 110607 to 1513 to 25
B-N65210232.8110 to 14050 to 1008512 to 2845 to 105
B-N100270242.9110 to 14060 to 13010020 to 25110 to 130
BD-N20-950 to 6510 to 309038 to 5210 to 23
BD-N65-2455 to 6512 to 3024068 to 9213 to 29
BD-N100-3150 to 6512 to 30310104 to 15630 to 70
  • Note 1: The table above indicates the guideline values of characteristics when using a 200 V AC coil during AC operation (B-N□), and when using 100 V DC during DC operation (BD-N□).
  • Note 2: Operating voltage is 20°C cold state, for both AC operation (at 60 Hz) and DC operation. For coils other than 200 V AC and 100 V DC, purchase approximately proportional to the voltage.
  • Note 3: Input and power consumption are shown as average values. Stays nearly the same even when using coils other than 200 V AC or 100 V DC.
  • Note 4: Coil current is the average value when applying 220 V 60 Hz during AC operation, and when applying 100 V DC. When using a coil other than the 200 V AC coil, divide the constant input by the coil voltage to find the coil. When using a coil other than the 100 V DC coil, divide the power consumption by the coil voltage.
  • Note 5: Operating time is the value when applying 220 V 60 Hz during AC operation, and 100 V DC during DC operation. Stays nearly the same even when using coils other than 200 V AC or 100 V DC.
Part Number
B-T21 AC200V 3B
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSCoil rated voltage
(V)
Dimension length
(mm)
Dimension width
(mm)
Dimension thickness
(mm)
Equipment Name Specifications Uses Rated Alternating Current b Contact, Triple Phase 200 to 220 V AC
(A)
Uses Rated Alternating Current b Contact, Triple Phase 380 to 440V AC
(A)
Main Contact Configuration

-

1 Piece(s) Quote -200 AC816381Main circuit B contact type electromagnetic contactorAC Operation18133b

Loading...

  1. 1
 

Basic Information

Operating Method Irreversible type Number of Poles 3 Auxiliary Contact 2a2b
Representative Standard CCC

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)