(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.

  • [Announcement] MISUMI Malaysia website new user interface. Clearer navigation, easy product search and more. Explore now! May contact us at (60) 3 7890 6399 for any inquiries.

BH MINI Series No-Fuse Breaker For Power Distribution Board (BH-C1 20A)

BH MINI Series No-Fuse Breaker For Power Distribution Board BH-C1 20A

Breaker for power distribution board.
[Features]
· Power supply side plug-in structure enables single-action mounting and shortened work time during power outages.
· Thin no-fuse breaker and earth leakage breaker with 2 contacts in a width dimension of 25 mm.
[Applications]
· Breaker for power distribution board branch circuit with agreed dimensions for electric light power distribution boards.

Part Number

Configured Part Number is shown.

BH-C1 20A

Power Distribution Board Breaker Specifications

ApplicationsNo-Fuse Breaker For Branch CircuitPlug-In Type No-Fuse Breaker On Power Supply Side
BH Mini (2P1E)BH Mini (2P2E)BH Mini (2P1E)BH Mini (2P2E)
Frame A50505050
Type NameBH-C1BH-C1DBH-C2BH-C2DBH-CP1NRBH-CP1NTBH-CP2
Rated current A
(standard ambient temperature 40°C)
15 20 3015 20 3015 20 3015 20 30
Number of contacts2 (2P1E)2 (2P2E)2 (2P1E)2 (2P2E)
Rated insulation voltage V265265265265
Rated operating voltage VAC----
Rated sensitivity current mA------
Operating time s or less------
Rated
short
circuit
breaking
capacity
kA


JIS C 8201-2-1
Ann.2
(Icu)
AC240 V--2.52.5-2.5
200 V------
100/
200 V
--55-5
100 V55--5-
DC125 V-1-2.5--
JIS C 8201-2-2
Ann.2
(Icu)
AC240 V------
200 V------
100/
200 V
------
100 V------
External
Dimensions
mm

a25252525
b95959595
c60606060
ca77777777
Product Mass kg0.140.160.130.14
Connection
Power supply side plug-in type--○ Power supply side plug-in type
Load side screw terminal type
○ Power supply side plug-in type
Load side screw terminal type
Power supply side plug-in type (AP) (Note 2)△ Note 3-△ Note 3---
Load side quick-connect terminal type (QT) (Note 1)
Note 3
-
Note 3
-
Accessory
devices

Warning switch (AL)--
Auxiliary switch (AX)--
Part sold separately
Lock cover (LC)
Reverse connections--
Electrical Appliance And Material Safety LawCompliantCompliantCompliantCompliant
Overcurrent tripping methodThermal - electromagnetic

Note 1: When ordering a quick-connect terminal (QT), specify “QT” in your order.
Note 2: When ordering a power supply side plug-in type (AP), specify “AP” in your order.
Note 3: Product is also available combining specifications for AP and QT. Please inquire for details.

Power Distribution Board Breaker External Dimensions

External Dimensions

Notes

1. The rated breaker capacity 100/200 V value is for single-phase 3-wire systems.
2. The rated voltage 240 V product can also be used in circuits with 240 V or less to ground, such as a three-phase 4-wire system, ect.
3. Variable voltage range in which electrical leakage protection function can operate.

Voltage Fluctuation Range

4. Alarm switch (AL) and auxiliary switch (AX) voltage

Alarm switch (AL) and auxiliary switch (AX) rating

5. Alarm switch (AL) and auxiliary switch (AX) rating
Use at 60 V, 0.6 A or higher. However, this can be used with input in the 5 to 60 V and 0.05 to 0.6 A range, or at 3 VA input and lower.
Please inquire regarding use at low voltage and current ranges less than these.

Part Number
BH-C1 20A
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSRated block capacity, voltages except VAC 100/200/400, VDC 250 Rated Current
(A)
Connection Method Specifications Rated block capacity AC 240 V
(kA)
Connection phase Power supply connection method Number of Elements
(Element)

-

1 Piece(s) Quote 6-20Surface typeFor branch circuitsNA-Screw terminal1

Loading...

  1. 1

Basic Information

Ampere frame 50AF Rated block capacity AC 100 V(kA) 5 Number of Poles 2
Mounting Method Fasten With Screws Dimension height(mm) 95 Dimension width(mm) 25
Dimension depth(mm) 77 Rated block capacity AC 415 V(kA) NA Rated block capacity DC 125 V(kA) NA
Load side connection method Screw terminal

Please check the type/dimensions/specifications of the part BH-C1 20A in the BH MINI Series No-Fuse Breaker For Power Distribution Board series.

Products like this...

Part Number
BH-C1 15A
BH-C2 20A
BH-CP2 20A
BH-CP2 30A
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipRoHSRated block capacity, voltages except VAC 100/200/400, VDC 250 Rated Current
(A)
Connection Method Specifications Rated block capacity AC 240 V
(kA)
Connection phase Power supply connection method Number of Elements
(Element)

-

1 Piece(s) Quote 6-15Surface typeFor branch circuitsNA-Screw terminal1

-

1 Piece(s) Quote -Available20Surface typeFor branch circuits2.5-Screw terminal2

MYR 272.17

1 Piece(s) 8 Day(s) or more 6Available20[Other] Plug-in typePower supply side plug-in shape2.5R-TPlug-in terminal2

-

1 Piece(s) Quote 6Available30[Other] Plug-in typePower supply side plug-in shape2.5R-TPlug-in terminal2

Additional Products in this Category

Customers Who Viewed This Item Also Viewed

Tech Support

Factory Automation, Electronics, Tools, & MRO (Maintenance, Repair and Operations)
Tel:(60) 3 7890 6399
9:00am - 6:00pm (Monday - Friday)
9:00am - 1:00pm (Saturday)