(!)Due to Microsoft's end of support for Internet Explorer 11 on 15/06/2022, this site does not support the recommended environment.
YM-206NDA series DC ammeter (mechanical indicator.)
[Features]
· Used for measuring current in power transmission/distribution lines, load equipment, etc.
· Size: W64 × H60 mm.
· Operating principle: moving coil type.
[Applications]
· An instrument for measuring and displaying current from AC and DC circuits.
Part Number
Configured Part Number is shown.
YM-206NDA 0-20A B
| Rectangular Meter | |||
|---|---|---|---|
| Y-2N Series | |||
| Size (Width × Height) mm | 64 × 60 | ||
| Model Name | YM-206NDA | ||
| Operating Principle | Moving coil type | ||
| Accuracy Class (Grade) | 2.5 | ||
| Scale Length (mm) | 55 | ||
| Weight (kg) | 0.07 | ||
| Meter Rating And Delivery Period Classification | Maximum Scale Value | Internal resistance (Ω) or voltage drop | |
| Direct Meter Note 1 | 100 μA | 2,000 Ω | |
| 200 μA | 1,200 Ω | ||
| 300 μA | 1,000 Ω | ||
| 500 μA | 730 Ω | ||
| 1 mA | 200 Ω | ||
| 3 mA | 70 Ω | ||
| 5 mA | 8 Ω | ||
| 10 mA | 2 Ω | ||
| 20 mA | 0.8 Ω | ||
| 50, 100 mA 200, 500 mA 1, 2, 5, 7.5 A 10, 15, 20, 30 A | 60 mV | ||
| Combined With Shunt | 1 A to 7,500 A | 60 mV, 100 mV (current consumption: approx. 20 mA) | |
| Special Specifications | With Lead Wire Adjustment Resistor | Can be manufactured | |
Note 1. Operating circuit voltage is 300 V or less.
For bi-directional deflection meters, please choose a specification according to the following.
For direct rating, manufacturing is possible if the larger of the left and right scales is 30 A or less.
For combined use with a shunt, please choose a scale so that the sum of the absolute values of the meter ratings is 60 mV or more.
Example: For a shunt rated 100 A, 60 mV
Ammeter scale -50 to 0 to +100 A
Ammeter rating -30 to 0 to +60 mV
(sum of absolute values = 90 mV ≧ 60 mV)

DC ammeter (direct)

DC ammeter (combined with shunt)
A dimension: 43

Dimensional Outline Drawing

Panel hole drilling dimensions
(view from front of panel)
| Connection method or CT ratio | Direct Connection | Management Guidelines | Red guidelines | Gauge Front Surface Dimensions (Width × Height)(mm) | 64 x 60 |
|---|
Please check the type/dimensions/specifications of the part YM-206NDA 0-20A B in the YM-206NDA Series DC Ammeter (Mechanical Indicator) series.
| Part Number |
|---|
| YM-206NDA 0-15A B |
| YM-206NDA 0-1A B |
| YM-206NDA 0-200MA B |
| YM-206NDA 0-20MA B |
| YM-206NDA 0-2A B |
| YM-206NDA 0-30A B |
| Part Number | Standard Unit Price | Minimum order quantity | Volume Discount | Days to Ship | RoHS | Scale |
|---|---|---|---|---|---|---|
- | 1 Piece(s) | Quote | 6 | 0-15A | ||
- | 1 Piece(s) | Quote | 6 | 0-1A | ||
- | 1 Piece(s) | Quote | 6 | 0-200mA | ||
- | 1 Piece(s) | Quote | 6 | 0-20mA | ||
- | 1 Piece(s) | Quote | 6 | 0-2A | ||
- | 1 Piece(s) | Quote | 6 | 0-30A |

How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy