MVVS under 100 V shielded PVC (MVVS-0.3SQ-2-15)

MVVS under 100 V shielded PVC MVVS-0.3SQ-2-15

Click this image to zoom it.

Move the mouse over the image to zoom

Shielded general purpose signal cable for low current circuits
[Features]
· Lightweight with a slim overall diameter and excellent flexibility, making it easy to handle during wiring.
· Features a braided shield, providing high noise reduction effect against radiated and external noise, as well as excellent flexibility.

PDF

Japanese Only

Part Number

Configured Part Number is shown.

MVVS-0.3SQ-2-15

Product Feature Details

  • Ultra-fine type
  • Instrument cable with braided shield (2 to 4 cores) / multi-core instrument cable with braided shield (5 to 40 cores)
  • Bending radius: overall diameter x 8 (fixed part)

Rating

  • Temperature: -10 to 60°C
  • Voltage: 100 V or less

Features

  • Wire core identification is done by color coding for up to 13 cores, and for 14 or more cores, identification is made by line color and combinations, making circuit identification easy.
  • The insulator and sheath features environmentally friendly PVC that does not contain lead. (Onamba nominal: Pb Free)
  • A drain wire (longitudinally attached) is provided, making terminal processing work easier.

Specifications Table

Multi-core braided shielded instrumentation cable

Number of wire cores
No. of cores
Conductor (AC)
Conductor (AC)
Insulator
Insulator

Stranded
outer diameter
mm

Shield
thickness
mm
Sheath thickness
Sheath
thickness
mm
Overall diameter
Finished
outer diameter
mm
Allowable current
(Reference value)
Maximum
Permissible current (reference value)
A
Approximate
weight

kg/km
Nominal
cross-sectional area
Nominal
Cross-sectional area
mm2
Configuration
No. of wires / Single wire diameter

No. of wires / Single wire diameter
Wires/mm
Wires/mm
Outer diameter

mm
Thickness

mm
Outer diameter

mm
5C0.312/0.180.70.31.33.50.31.06.2360
0.520/0.180.90.31.54.10.31.06.8480
0.7530/0.181.10.31.74.60.31.07.3595
1.2550/0.181.50.42.36.20.31.08.98145
237/0.261.80.42.67.00.31.09.710185
6 to 7C0.312/0.180.70.31.33.90.31.06.63 (3)65 (70)
0.520/0.180.90.31.54.50.31.07.24 (4)90 (95)
0.7530/0.181.10.31.75.10.31.07.85 (5)105 (120)
1.2550/0.181.50.42.36.90.31.09.67 (7)165 (180)
237/0.261.80.42.67.80.31.010.510 (9)205 (230)
8C0.312/0.180.70.31.34.30.31.07.0375
0.520/0.180.90.31.55.00.31.07.74100
0.7530/0.181.10.31.75.60.31.08.35130
1.2550/0.181.50.42.37.60.31.010.37195
237/0.261.80.42.68.60.31.011.39265
10C0.312/0.180.70.31.35.20.31.07.9290
0.520/0.180.90.31.56.00.31.08.73120
0.7530/0.181.10.31.76.80.31.09.54155
1.2550/0.181.50.42.39.20.31.011.96250
237/0.261.80.42.610.40.351.013.48340
12C0.312/0.180.70.31.35.40.31.08.1295
0.520/0.180.90.31.56.20.31.08.93130
0.7530/0.181.10.31.77.10.31.09.84180
1.2550/0.181.50.42.39.60.31.012.36300
237/0.261.80.42.610.80.351.013.88380
16C0.312/0.180.70.31.36.10.31.08.82125
0.520/0.180.90.31.57.10.31.09.83170
0.7530/0.181.10.31.78.00.31.010.74225
1.2550/0.181.50.42.310.80.351.113.85365
20C0.312/0.180.70.31.36.70.31.09.42145
0.520/0.180.90.31.57.80.31.010.53200
0.7530/0.181.10.31.78.80.31.011.53260
1.2550/0.181.50.42.312.00.351.115.05455
30C0.312/0.180.70.31.38.30.31.011.02210
0.520/0.180.90.31.59.60.31.012.32280
0.7530/0.181.10.31.710.90.351.113.93375
1.2550/0.181.50.42.314.80.351.218.04740
The allowable current is a reference value calculated based on JCS No. 0168-1. (Under ambient temperature 30°C, with a single wire in air)

Current Reduction Factor

· In the case of ambient temperature
Ambient temperature (°C)3540455055
Current Reduction Factor0.910.820.710.580.41
The allowable current is a calculated value at an ambient temperature of 30°C with a single cable in the air, and is not a guaranteed value.
If the ambient temperature is 30°C or higher, multiply the allowable current by the above current reduction factor.
(Example) Allowable current value when the ambient temperature is 40°C with MVVS 0.3 mm2 duplex: 2.0 x 0.82 = 1.64 (A)

Wire Core Identification

Insulator Color

  • 2 cores: white, black
  • 3 cores: white, black, red
  • 4 cores: white, black, red, green

sheath color

Gray

Surface display

MVVS under 100 V shielded PVC surface marking

Structure

■ Instrumentation cable with braided shield

MVVS under 100 V shielded PVC structural diagram 1

No filler is included.

 

■ Multi-core instrumentation cable with braided shield

MVVS less than 100 V shielded PVC Structural Drawing2

Arrangement diagram

MVVS less than 100 V shielded PVC Wiring Diagram

Arrangement table

MVVS less than 100 V shielded PVC Wiring Table
 
Line marking example
  • White/Black: Black line on white background
MVVS less than 100 V shielded PVC Line Marking Example
 
 
 

Instructions / Usage Examples

Applications

Mainly used for wiring electronic devices and measuring instruments under 100 V, especially in locations where noise may be an issue.

Cautions/Prohibitions

Precautions for Use

Do not use in environments that require sliding properties or continuous flexibility, such as cable carriers or robot arms.

Part Number
MVVS-0.3SQ-2-15
Part NumberStandard Unit PriceMinimum order quantityVolume DiscountDays to ShipOverall Length
(m)
Conductor Cross Section
(mm2)
AWG size
(AWG)
Number Of Cores
(Core)
Finished outer diameter
(mm)
Type Applications

MYR 95.79

1 Piece(s) 12 Day(s) or more 150.32225Round typeFor fixed part

Loading...

  1. 1
 

Basic Information

Rated Voltage 100V Shield Available Sheath (outer coating) color Gray
Grounding Wire NA Sheath (outer coating) material PVC Insulation body materials PVC
Power Supply / Signal For Signals